• Title/Summary/Keyword: GAs analysis

Search Result 9,117, Processing Time 0.044 seconds

Case Studies for SMR Natural Gas Liquefaction Plant by Capacity in Small Scale Gas Wells through Cost Analysis (소규모 가스전 규모에 따른 SMR 천연가스 액화 플랜트 용량별 비용 분석 사례연구)

  • Lee, Inkyu;Cho, Seungsik;Lee, Seungjun;Moon, Il
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.46-51
    • /
    • 2016
  • Natural gas liquefaction process which spends a huge amount energy is operated under cryogenic conditions. Thus, many researchers have studied on minimizing energy consumption of LNG plant. However, a few studied for cost optimization have performed. This study focused on the cost analysis for the single mixed refrigerant (SMR) process, one of the simplest natural gas liquefaction process, which has different capacity. The process capacity is increased from 1 million ton per annum (MTPA) to 2.5 MTPA by 0.5 MTPA steps. According to the increase of plant size, only flow rate of natural gas and mixed refrigerant are increased and other operating conditions are fixed. Aspen Economic Evaluator(v.8.7) is used for the cost analysis and six tenths factor rule is applied to obtain multi stream heat exchanger cost data which is not supplied by Aspen Economic Evaluator. Moreover, the optimal plant sizes for different sizes of gas wells are found as the result of applying plant cost to small scale gas wells, 20 million ton (MT), 40 MT, and 80 MT. Through this cost analysis, the foundation is built to optimize LNG plant in terms of the cost.

A Study on Estimation of Initial Gas in Place for Coalbed Methane Field Using Production Data at Canada (생산자료를 이용한 캐나다 CBM 원시부존량 평가 연구)

  • Seo, Hyeongjun;Moon, Bryan;Kim, Kihong;Han, Jungmin;Kwon, Sunil
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.64-77
    • /
    • 2018
  • This paper presents the prediction of the original gas in place(OGIP) by using the material balance method and decline curve analysis method with production history and pressure transient test data for four coalbed methane wells in the Horseshoe Canyon field. In this study, the conventional gas equation and the Jensen and Smith(J&S) equation were used to material balance analysis, and the Arps' empirical correlation and Khaled method were applied to decline curve analysis. From the results, the OGIP estimated from the conventional gas and the J&S method was small in difference as under 12%. Also, in case of decline curve analysis, it was found that the Khaled method has appropriated to calculate the OGIP, because the OGIP was estimated as unlimited value by the Arps' equation from the decline exponent of 1 - 3.5. The OGIP difference between conventional gas method and Khaled method was calculated as 8.67% ~ 31.04%, and those between J&S method and Khaled method was 13.67% ~ 26.49%.

Exergy-Based Performance Analysis of Heavy-duty Gas Turbine in Part-Load Operating Conditions (엑서지를 이용한 대형 발전용 가스터빈의 부분부하 성능 분석)

  • Song, T.W.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.751-758
    • /
    • 2001
  • Exergy concept is applied to the analysis of part-load performance of gas turbine engine. Exergy is a useful tool to find the source of irreversibility in thermal system. In this study, details of the performance characteristics of a heavy-duty gas turbine, l50MW-class GE 7FA model, are described by theoretical investigations with exergy analysis. Result shows that exergy destruction rate of gas turbine increases with decreased load, which means increase of irreversibility. Also, it is found that variations of IGV angle and amount of cooling air for turbine blades are closely related to the inefficiencies of compressor and turbine, respectively.

  • PDF

Analysis of Design and Operation Performance of Micro Gas Turbine : Part 1 - Performance Analysis Program (마이크로 가스터빈 설계 및 운전 성능 분석 : 제1부 - 성능해석 프로그램)

  • Kim, Jeong Ho;Kang, Do Won;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.4
    • /
    • pp.22-29
    • /
    • 2015
  • In this study, an in-house program to predict steady state operation of micro gas turbines is constructed using MATLAB. The program consists of two parts: design and off-design simulations. The program is fully modular in its structure, and performance of each component (compressor, combustor, turbine, recuperative heat exchanger and pipe elements) is calculated in a separate calculation module using mass and energy balances as well as models for off-design characteristics. The off-design modules of compressor and turbine use performance maps, which are program inputs. The off-design operation of a micro gas turbine under development was predicted by the program. The prediction results were compared with those by commercial software, and the validity of the in-house program was confirmed.

Expert System for Fault Diagnosis of Transformer

  • Kim, Jae-Chul;Jeon, Hee-Jong;Kong, Seong-Gon;Yoon, Yong-Han;Choi, Do-Hyuk;Jeon, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.45-53
    • /
    • 1997
  • This paper presents hybrid expert system for diagnosis of electric power transformer faults. The expert system diagnose and detect faults in oil-filled power transformers based on dissolved gas analysis. As the preprocessing stage, fuzzy information theory is used to manage the uncertainty in transformer fault diagnosis using dissolved gas analysis. The Kohonen neural network takes the interim results by applying fuzzy informations theory as inputs, and performs the transformer fault diagnosis. The Proposed system tested gas records of power transformers from Korea Electric Power Corporation to verify the diagnosis performance of transformer faults.

  • PDF

Assessment and Analysis of Coal Seam Gas Water Management Study for Water Resource Production -1. Water Production (물 자원 생산을 위한 Coal Seam Gas Water Management Study의 평가 및 분석 -1. 용수 생산)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1395-1407
    • /
    • 2014
  • Coal seam gas (CSG) production involves extracting methane from coal seams with ground water which is so called a primary by-product of this process, and is often rich in salts and other constituents. The predicted large volume and variable quality of this water make water management a topic associated with CSG production. In the past, the amount of this water used to be pumped into the vacant aquifer, or into the river during the life of individual production wells. Australian government make a strategies for management and beneficial use of the water. From this point of view, a detailed assessment has not been undertaken, it is necessary for water resource production to analysis the "Coal Seam Gas Water (CSG Water) Management Policy Study" published in Queensland, Australia.

Exergy Analysis of Regenerative Gas Turbine Systems with Afterfogging (압축기 출구 물분사가 있는 재생 가스터빈 시스템의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • An exergy analysis is carried out for the regenerative gas turbine cycle which has a potential of enhanced thermal efficiency and specific power owing to the more possible water injection than that of inlet fogging under the ambient conditions. Using the analysis model in the view of the second law of thermodynamics, the effects of pressure ratio, water injection ratio and ambient temperature are investigated on the performance of the system such as exergetic efficiency, heat recovery ratio of recuperator, exergy destruction or loss ratios, and on the optimal conditions for maximum exergy efficiency. The results of computation for the typical cases show that the regenerative gas turbine system with afterfogging can make a notable enhancement of exergy efficiency.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

Transformer Fault Recognition and Interpretation Using Kohonen Feature Mapping (코호넨 특징 대응을 이용한 변압기 고장 인식 및 해석)

  • Yoon, Yong-Han;Kim, Jae-Chul;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.864-866
    • /
    • 1997
  • This paper presents fault recognition and interpretation in power transformers using dissolved gas analysis embedded Kohonen feature mapping. The imprecision of gas ratio analysis in dissolved gas analysis are managed by mapping in accordance with learning of Kohonen neural network. To verify the effectiveness of the proposed system, it has been tested by the historical gas records to power transformers of Korea Electric Power Corporation. More appropriate fault types can support the maintenance personnels to increase the disgnostic performance for fault of power transformers.

  • PDF

Technical study on quantitative analysis of the toxic gas concerning the combustion property of interior materials of railway car (철도차량용 내장 재료의 연소특성을 고려한 유해가스 정량분석 기법연구)

  • Park, Ji-Young;Lee, Cheul-Kyu;Lee, Duck-Hee;Jung, Woo-Sung;Chung, Hoe-Il
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1114-1118
    • /
    • 2008
  • In previous fire accident of railway car, the fatality was relatively high by toxic gas poisoning cause of closed space. So the necessity of quantifying toxic gas in combustion gas was recognized and then, FT-IR spectroscopy was introduced for real-time analysis of mixed gases and stimulated analysis of the concentration of several gases. Thus, in this study, absorption bands using FT-IR were obtained by each component of combustion gases for interior materials of railway car such as flooring materials and moquette seat. And then the sample spectra were compared with the spectra of NO, $NO_2$, $SO_2$ reference gases, we could obtain some identical peaks of them.

  • PDF