Mathematical Modeling about Magnetic Attractive Force of Magnetic Bearing (자기베어링 구동용 전자석의 흡인력에 대한 수학적 모델링)

  • Choi, G.H.;Yang, J.H.;Choung, K.G.
    • Journal of Power System Engineering
    • /
    • v.16 no.3
    • /
    • pp.64-68
    • /
    • 2012
  • Because the magnetic bearing supports levitating body without contact, wear, noise and vibration are very small comparing with mechanical bearings, it is very useful to high revolution machinery. In general, the magnetic attractive force function that is proportional to square of control current(x), and inversely proportional to square of an air gap(i) has been widely used. This paper proposed the new magnetic attractive force function that is proportional to cube of the control current, and inversely proportional to square of the air gap. The function was optimized to minimize the cost function that is the percentage of deviation about the change of a proportional constant(k), using the experimental data, ie, control currents and air gaps.

DC railway regenerative energy by dividing, the development of the battery can be stored power conversion device (직류철도 회생에너지를 분압한 배터리 저장 가능한 전력 변환장치 개발)

  • Cho, Kyeong-Sig;Park, Ga-Woo;Shin, Seung-Kwon;Kim, Hyung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.50-54
    • /
    • 2016
  • 본 논문에서는 전동차의 정차 시 발생하는 회생에너지를 Battery에 충전할 수 있는 전력 변환 장치를 제안한다. 제안된 전력 변환장치는 DC 1500~2000의 가선전압을 분압하여 저압스위칭 소자 적용하며, 고주파 절연 변압기를 적용하였다. 이를 통해 시스템의 스위칭 주파수를 상승시켜 수동 소자들의 사이즈 축소 및 비용 절감 효과를 높이고, 가선과 Battery의 전기적 절연으로 시스템의 안정성을 높였다. 또한 가선 전압 분압을 통해 입력 전압의 변화에 유동적으로 대응할 수 있으며, 시스템의 병렬 구성을 통해 용량의 확장성을 가지게 된다. 제안된 논문에서 제안된 회생에너지 전력 변환 장치는 20[kW] 회생 컨버터 모듈의 5직렬 구성을 통해 100[kW]급 회생 컨버터 유닛을 구성하였으며, 회생 컨버터 유닛을 5병렬로 구성하여 500[kW]급 회생 전력 변환시스템을 구성하였다. 제안된 회생에너지 시스템은 모의 가선 전압 장치 및 Battery 부하를 통해 시스템의 타당성을 검증 한다.

  • PDF

Simple High Power Factor Three Phase Rectifier with Elimination of DC Link LC Filter (DC 링크의 LC 필터를 제거한 3상 고역률 정류기)

  • Kim, J.H.;Kim, Y.C.;Koo, H.G.;Lee, H.W.;Song, D.I.;Cho, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2237-2239
    • /
    • 1997
  • The conventional three phase rectifier with Bulk LC output filter has been widely used in the industry because of simple circuit, low cost and high power factor (90%). One of the biggest drawback of this rectifier is bulky and havy. This is serious especially for aerospace applications. To solve this problem a new simple rectifier is presented. Operation of the proposed rectifier is illustrated and verifyed by PSpice simulation.

  • PDF

A Study On Synchronous Rectification Of Push-Pull Converter For Efficiency Improvement (효율개선을 위한 Push-Pull Converter의 동기정류에 관한 연구)

  • Kim D.J.;Kim Y.G.;Kim L.H;Won C.Y.;Kim G.S.;Choi S.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.345-351
    • /
    • 2003
  • Single winding self driven synchronous rectification(SWSDSR) scheme is based on an additional winding in the power transformer (auxiliary winding). It allows for maintaining the synchronous rectifiers on even when the voltage in the transformer is zero, which is impossible to do in traditional self-driven approaches. Its technique is verified to improve the efficiency by experiment. In this paper, there are compared self driven synchronous rectification(SDSR) with SWSDSR about the efficiency

  • PDF

Antioxidative Activity of Medicinal Plants from Korean (한국산 한약재의 항산화 활성 효과)

  • Lee, Jeong-Ho;Chong, Myong-Soo;Lee, Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 2006
  • This study was performed to determine antioxidative activity of solvent extracts from medicinal plant. As the result, methanol extract from Saurus chinensis Bail and Glycine soya exhibited superior free radical activity as well as reducing power. In particular, methanol extract from Saurus chinensis Bail showed high free radical activity with 130.08${\mu}g/mL$ as $IC_{50}$ value and strong reducing power at concentration of $400{\mu}g/mL$.

  • PDF

A STUDY ON DEVELOPMENT OF UNINTERRUPTIBLE POWER SUPPLY ADOPTED INSULATED GATE BIPOLAR TRANSISTORS (IGBT를 채용한 무정전전원공급장치 개발에 과한 연구)

  • Baek, B.S.;Kim, Y.P.;Han, G.J.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.462-465
    • /
    • 1991
  • In this paper, a newly developed uninterruptible power supply adopted insulated gate bipolar transistors (IGBT'S) is introduced. The focus is on harmonic reduction, high efficiency and so on. The overview, hardware and software of the newly developed ups system are also discussed. Finally, the merit of the newly developed ups compared with conventional ups is described.

  • PDF

Design of a CMOS DC-to-DC Converter for Portable Devices (휴대용 기기를 위한 CMOS DC-DC 변환기 설계)

  • O, N.G.;Lee, J.K.;Cho, I.H.;Jang, S.H.;Cha, C.H.;Yu, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.520-521
    • /
    • 2008
  • This paper describes a low voltage, low-power CMOS buck DC/DC converter, which has a simple common-gate current sensing circuit. It consumes low power because it includes less transistors than other converters which use operational amplifiers for current sensing. The designed DC-DC converter is fabricated in a 0.18um CMOS technology. A maximum efficiency of 88% has been obtained with the proposed circuit. It has $2V{\sim}3.7V$ input voltage range, $1V{\sim}2.5V$ output voltage range and maximum output current of 1000mA.

  • PDF

Steam Temperature Controller Design of Power Plant Superheater (발전기 과열기의 증기 온도 제어기 설계)

  • Hong, Hyun-Mun;Jeon, B.S.;Kim, J.G.;Kang, G.B.;Lee, B.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.412-414
    • /
    • 2005
  • In this paper, we present a method of fuzzy controller design for the power plant superheater in the form of bilinear system. For the steam temperature control, the input variables are constructed by the area of difference between the profiles estimated from bilinear observer and reference profiles, and the time rate of change. We estimate the control rules by T. Takagi and M. Sugeno's fuzzy model. The feasibilities of the suggested method are illustrated via the computer simulation result.

  • PDF

Improvement of Power Quality of Single-phase Utility Interactive Inverter using Repetitive Controller (반복제어기를 적용한 단상 계통연계형 인버터의 전력품질 개선)

  • Kim, J.H.;Mok, H.S.;Choe, G.H.;Lee, J.W.;Chung, G.B.;Lee, J.M.;Cho, Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.11-14
    • /
    • 2007
  • In recent years, installation of the new and renewable energy system is rapidly increasing. Because the new and renewable energy system is a practical distributed generation system to save energy resources and to keep environments clean. Conventional single-phase utility interactive inverter controls output current by using PI current controller. However, this method is insufficient to suppress harmonic current resulted from nonlinear loads in grid line. In this paper, in order to suppress periodic waveform distortion and improve THD(Total Harmonic Distortion), new type current controller added a parallel repetitive controller is proposed and then performance of the proposed controller was verified with computer simulation.

  • PDF

A Study on Mixed Mode I/II Interlaminar Fracture Toughness of Carbon Fiber Reinforced Plastic Composites (CFRP 복합재료의 혼합모드 I/II 층간파괴인성치에 관한 연구)

  • Kim, H.J.;Park, M.I.;Kim, J.D.;Koh, S.W.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.48-54
    • /
    • 2000
  • This paper describes the effect of molding pressure, specimen geometries for Mixed Mode I/II interlaminar fracture toughness of carbon fiber reinforced plastic composites by using asymmetrical double cantilever beam(ADCB) specimen. The value of $G_{I/IIC}$ as a function of various molding pressure is almost same at 307, 431, 585 kPa. However it shows the highest value under 307 kPa molding pressure. The effect of $G_{I/IIC}$ due to the change of initial crack length of ADCB specimen was almost negligible in this study. It turns out that the condition for mix mode quasi-static crack growth in ADCB specimen is the ratio of the crack length to that of the specimen, i.e., ${\alpha}/L<0.4$.

  • PDF