• Title/Summary/Keyword: G-power

Search Result 4,956, Processing Time 0.038 seconds

3-DESIGNS DERIVED FROM PLANE ALGEBRAIC CURVES

  • Yu, Ho-Seog
    • Bulletin of the Korean Mathematical Society
    • /
    • v.44 no.4
    • /
    • pp.817-823
    • /
    • 2007
  • In this paper, we develop a simple method for computing the stabilizer subgroup of a subgroup of $$D(g)={{\alpha}{\in}\mathbb{F}_q|there\;is\;a\;{\beta}{\in}{\mathbb{F}}^x_q\;such\;that\;{\beta}^n=g(\alpha)}$$ in $PSL_2(\mathbb{F}_q)$, where q is a large odd prime power, n is a positive integer dividing q-1, and $g(x){\in}\mathbb{F}_q[x]$. As an application, we construct new infinite families of 3-designs (cf. Examples 3.4 and 3.5).

NOMALIZERS OF NONNORMAL SUBGROUPS OF FINITE p-GROUPS

  • Zhang, Qinhai;Gao, Juan
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.1
    • /
    • pp.201-221
    • /
    • 2012
  • Assume G is a finite p-group and i is a fixed positive integer. In this paper, finite p-groups G with ${\mid}N_G(H):H{\mid}=p^i$ for all nonnormal subgroups H are classified up to isomorphism. As a corollary, this answer Problem 116(i) proposed by Y. Berkovich in his book "Groups of Prime Power Order Vol. I" in 2008.

Average Length and Bounds on the Busy Period for a k-out-of-n : G System with Non-identical Components

  • Jung, Kyung-Hee
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.2
    • /
    • pp.123-130
    • /
    • 1992
  • The model of k-out-of n : G repairable system with identical components is extended to a repairable system with n different components. The objective is to analytically derive the mean time of the busy period for a k-out-of-n : G system with unrestricted repair. Then, the lower and upper bounds on the average time of the busy period of the n-component system with restricted repair are also shown.

  • PDF

Leaching Kinetics of Yttrium Extraction from Coal Fly Ash using Sulfuric Acid

  • Kim, Jae-kwan;Park, Seok-un;Hong, Jun-seok;Shin, Dong-ik;Jeong, Jae-hyeok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • Leaching kinetics for extracting yttrium from the coal fly ash was investigated in the presence of sulfuric acid during extraction. The leaching kinetics of yttrium were conducted at reactant densities of 5~1,000 g coal fly ash per L of $1.0{\sim}10.0N\;H_2SO_4$, agitation speed of 250 rpm and temperature ranging from 30 to $90^{\circ}C$. As a result, the leaching kinetic model was determined in a two-step model based on the shrinking core model with spherical particles. The first step was proceeded by chemical reaction at ash surface, and the second step was proceeded by ash layer diffusion because the leaching conversion of yttrium by the first chemical reaction increases with increased the time irrelevant to the temperature whereas it increases with increased the leaching temperature. The activation energy of the first chemical leaching step was determined to be $1.163kJmol^{-1}$. After the first chemical reaction, the activation energy of ash layer diffusion leaching was derived to be $41.540kJmol^{-1}$. The optimum conditions for leaching the yttrium metal of 60 % were found to be the slurry density of 250 g fly ash per L of $H_2SO_4$, solvent concentration of $2.0N\;H_2SO_4$, second step leaching of temperatures of $30^{\circ}C$ for 3 hours and then $90^{\circ}C$ for 3 hours at agitation rate of 250 rpm.

Development of Power Supplies for Radiation Monitoring System and Process Control System of Korean-type Standard Nuclear Pourer Plants (한국형 표준원전의 방사선감시계통 및 공정제어계통 전원공급기 국산화 개발)

  • Roh, J.H.;Kwon, Y.G.;Jang, D.S.;Oh, C.Y.;Lee, C.H.;Kim, Y.K.;Ju, D.S.;Cho, H.M.;Park, W.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.515-517
    • /
    • 2008
  • 현재 가동 중인 원자적발전소 계측제어설비의 전원공급기를 살펴보면 인버터 또는 별도의 교류를 입력전원으로 사용한다. 직류 전원공급기들은 설비의 중요도예 따라 이중화로 구성된 설비도 있고 그렇지 않은 기기나 설비도 있다. 이중화로 구성된 전원공급기라 해도 교류 입력전원이 동일하다면 교류 입력이 상실될 때 이중화로 구성된 직류전원도 상실되어 관련계통의 가동이 정지된다. 이러한 문제점을 해결하기 위해서는 각기 다른 교류입력전원으로 동작되는 이중화전원공급기로 구성되는 것이 가장 바람직하다. 본 연구개발의 목적은 두 종의 설비에 소요되는 3종의 직류전원 공급기를 원자력 안정성등급으로 국산화하는 연구이다. 기존 제품들은 3종 모두 리니어 방식의 제품이지만, 방사선감시 계통 현장제어기의 5V로직 전원공급기와 공정제어계통 전원공급자는 전력변환효율이 높고 소형, 정량화가 가능한 SMPS(Switched Mode Power Supply) 방식으로 개발하였다. 방사선감시계통 현장제어기의 PCA(Printed Circuit Assembly) 저전압공급기는 다양한 종류의 출력전압과 저 전류형이므로 안정성 면에서 동일한 형식의 리니어 방식으로 개발하였으며 3종류 모두 출력용량을 20% 이상 향상시켰다. 또한, 논문을 통해 SMPS 방식의 전원공급기의 핵심 부품인 Control Module을 Hybrid IC형으로 자체 설계하여 성능이 우수한 제품을 지속적으로 생산할 수 있는 기틀을 마련하고자 한다.

  • PDF

Preliminary Study on the Internal Dosimetry Program for Carbon-14 at Korean CANDU Reactors (중수로원전에서 발생하는 $^{14}C$에 대한 내부피폭 선량평가 프로그램에 관한 예비 조사)

  • Kong T.Y.;Kim H.C.;Park G.;Hang D.W.;Lee G.J.;Lee S.K.;Park S.C.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.317-320
    • /
    • 2005
  • More strict radioactive regulations are applied to Korean nuclear power plants (NPPs) since ICRP-60 recommendation for radiation protection and has been enforced since 2003. In particular. carbon-14 and tritium concentrations are significantly higher at CANDU reactors compared to PWR reactors and this increases the risk of internal radiation exposure to workers at CANDU NPPs. Thus, it is necessary to estimate the exact amount of internal radiation exposure to workers fur radiological protection at CANDU reactors. In this paper, the current dosimetry method for carbon-14 is analyzed for the establishment of internal dosimetry for carbon-14 at domestic NPPs.

  • PDF

Determination of Proto Type for 345kV CV Cable Accessories (345kV CV 케이블 접속함의 Proto Type 선정)

  • Lee, S.K.;Kim, I.T.;Son, S.H.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

Impact-resistant design of RC slabs in nuclear power plant buildings

  • Li, Z.C.;Jia, P.C.;Jia, J.Y.;Wu, H.;Ma, L.L.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3745-3765
    • /
    • 2022
  • The concrete structures related to nuclear safety are threatened by accidental impact loadings, mainly including the low-velocity drop-weight impact (e.g., spent fuel cask and assembly, etc. with the velocity less than 20 m/s) and high-speed projectile impact (e.g., steel pipe, valve, turbine bucket, etc. with the velocity higher than 20 m/s), while the existing studies are still limited in the impact resistant design of nuclear power plant (NPP), especially the primary RC slab. This paper aims to propose the numerical simulation and theoretical approaches to assist the impact-resistant design of RC slab in NPP. Firstly, the continuous surface cap (CSC) model parameters for concrete with the compressive strength of 20-70 MPa are fully calibrated and verified, and the refined numerical simulation approach is proposed. Secondly, the two-degree freedom (TDOF) model with considering the mutual effect of flexural and shear resistance of RC slab are developed. Furthermore, based on the low-velocity drop hammer tests and high-speed soft/hard projectile impact tests on RC slabs, the adopted numerical simulation and TDOF model approaches are fully validated by the flexural and punching shear damage, deflection, and impact force time-histories of RC slabs. Finally, as for the two low-velocity impact scenarios, the design procedure of RC slab based on TDOF model is validated and recommended. Meanwhile, as for the four actual high-speed impact scenarios, the impact-resistant design specification in Chinese code NB/T 20012-2019 is evaluated, the over conservation of which is found, and the proposed numerical approach is recommended. The present work could beneficially guide the impact-resistant design and safety assessment of NPPs against the accidental impact loadings.