• Title/Summary/Keyword: G-power

Search Result 4,956, Processing Time 0.06 seconds

Combination System Design of 5G Candidate Modulation and Full Duplex Communication for the Spectrum Efficiency Enhancement (스펙트럼 효율 향상을 위한 전이중 통신 방식과 5G 후보 변조기술과의 결합시스템 설계)

  • An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.369-376
    • /
    • 2016
  • In this paper, we propose and design a SSD(Simultaneous Single band Duplex) system using 5G(Generation) candidate modulations. Especially, we consider HPA(High Power Amplifier) nonlinearity in the proposed system. And then, we evaluate and analyze performance of the proposed system. As simulation results, performance of SSD-OFDM(Orthogonal Frequency Division Multiplexing), SSD-FMC (Universal Filtered Multi-Carrier), and SSD-FBMC(Filter Bank Multi-Carrier) is severely degraded by HPA nonlinearity. However, performance of SSD-OFDM, SSD-UFMC, and SSD-FBMC is similar in the same condition. That is, OFDM, UFMC, and FBMC have a similar PAPR(Peak to Average Power Ratio) characteristic. Finally, we can confirm that the proposed SSD system can not cancel(SI) self-interference effectively by strong HPA nonlinearity. That is, Reducing PAPR is important in order to avoid effect of HPA nonlinearity in the proposed SSD system.

Generalized Combined Power and Rate Adaptations in DS/CDMA Communications over Fading Channels (페이딩 채널에서 직접 대역확산 부호분할 다중접속 통신을 위한 일반화된 혼합 전력/전송률 적응화 기법)

  • Lee, Ye Hoon;Kim, Dong Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.680-687
    • /
    • 2013
  • We investigate a generalized combined power and rate adaptation scheme in direct-sequence (DS) code-division multiple-access (CDMA) communications over Nakagami fading channels. The transmission power allocated to user i is proportional to $G^p_i$, where $G_i$ is the channel gain of user i and p is a real number, and the data rate (i.e., spreading gain) is jointly adapted so that a desired QoS is maintained. We analyze the average data rate of the proposed adaptation scheme subject to fixed average and peak transmission power constraints. Our results show that the proposed joint adaptation scheme provides a significant performance improvement over power-only and rate-only adaptation.

A Study on the V2G Application using the Battery of Electric Vehicles under Smart Grid Environment (스마트그리드 환경에서 전기자동차 배터리를 이용한 V2G의 활용방안에 관한 연구)

  • Choi, Jin-Young;Park, Eun-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • This study examines the system and process of battery stored energy in vehicles and suggest the effective area for the use of V2G(vehicle-to-grid) from Jeju Smart Grid Demonstration Project. V2G means technology of electric power transmission from the battery of electric-drive vehicles to state grid. As for the increasing of effectiveness for demand-side control, V2G is a very good alternative. In the U.S., the utilization of electric vehicles is under 40% on average. In this case, we can use he battery of electric vehicle as role of frequency regulation or generator of demand-side resource. V2G, which is the element of Smart Transportation, consists of electric vehicle battery, BMS(battery management system), OBC(on-board charger), charging infrastructure, NOC(network operating center) and TOC(total operation center). V2G application has been tested for frequency regulation to secure the economical efficiency in the United States. In this case, the battery cycle life is not verified its disadvantage. On the other hand, Demand Response is required by low c-rate of battery in electric vehicle and It can be small impact on the battery cycle life. This paper concludes business area of demand response is more useful than frequency regulation in V2G application of electric vehicles in Korea. This provides the opportunity to create a new business for power grid administrator with VPP(virtual power plant).

Comparative Study of Electron Donating Ability, Reducing Power, Antimicrobial Activity and Inhibition of ${\alpha}$-glucosidase by Sorghum bicolor Extracts (국내산 수수(Sorghum bicolor) 품종에 따른 전자공여능, 환원력, 항균활성 및 ${\alpha}$-glucosidase 저해활성의 비교)

  • Sa, Yeo-Jin;Kim, Ju-Sung;Kim, Myeong-Ok;Jeong, Hyun-Ju;Yu, Chang-Yeon;Park, Dong-Sik;Kim, Myong-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.598-604
    • /
    • 2010
  • Electron donating ability (EDA), reducing power, total phenolic contents, total flavonoid contents, antimicrobial activity, and ${\alpha}$-glucosidase inhibitory effects of twenty-two sorghum varieties were examined using ethanol extracts (70%, v/v). The electron donationg abilities (EDA) of Mesusu and Bulgeunjangmoksusu (94% at 10 ${\mu}g$/mL) indicated higher antioxidant activity compared to those of other varieties and standard antioxidants such as BHT (13%) and BHA (74%). The reducing power of Mesusu ($OD_{700}$=0.71) suggested higher antioxidant activity, which was dependent on sample concentration. Bitjarususu showed the highest content of total phenolics (22.9 mg GAE/g); however, extracts from Heuinsusu exhibited the lowest content of total phenolics (16.4 mg GAE/g). Jangmoksusu showed the highest total flavonolic contents (3.5 mg QE/g), and Sigyeongsusu and Chal (GS) susu displayed the most antibacterial activity (MIC=8 ${\mu}g$/mL) against Escherichia coli. Extracts of Bulgeunjangmoksusu, Moktaksusu, and Ginjangmoksusu showed the highest ${\alpha}$-glucosidase inhibitory effect (98%) at the concentration of 5 ${\mu}g$/mL.

Antioxidant Potential in the Fruits of Pyrus Species (Pear) in Korea

  • Park, Young-Ki;Kim, Sea-Hyun;Chung, Hun-Gwan
    • Korean Journal of Medicinal Crop Science
    • /
    • v.15 no.5
    • /
    • pp.335-338
    • /
    • 2007
  • Five samples (Bakwoonbae, Chungsilbae, Sandolbae, Dolbae, and Chuwhangbae) of Pyrus species differing in their origin of production were analyzed for total phenolic content, vitamin C content, and antioxidant activities. Two antioxidant activities were measured by the free-radical scavenging activity and reducing power method. Total phenolic content of the Chungsilbae extract (20.35 mg/g) was higher than those of other pears. Vitamin C content in five Pyrus species ranged from $420.32\;{\mu}g/g$ in Sandolbae to $659.75\;{\mu}g/g$ in Bakwoonbae. Chungsilbae also had the highest free radical scavenging activity (76.56%) and reducing power (0.35).

1MVA Superconducting Generator Design (1MVA 급 초전도발전기 설계)

  • 백승규;손명환;권영길;류강식;조영식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.158-161
    • /
    • 2000
  • Generally superconducting generators(S. G.'s) will be classified into 2 types according to their field coil shape. The first one is race-trace type and the other is saddle type. Race-track type S.G.'s have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 4 poles. On the other hand saddle type S.G.'s correspond to conventional cylindrical generators with 2 poles used for large turbines in power plants. In this paper 1MVA S.G. with saddle type field coil is electromagnetically designed and based on the research results from development of 30kVA S.G. with race-track type field oils in our group. other parts such as cooling systems and power leads are presented.

  • PDF

New Single Stage Power Factor Correction AC/DC Converter based on Zero Voltage Switching Full Bridge Topology (영전압 스위칭 풀 브릿지 토폴로지를 기반으로 한 새로운 단일 전력 단 역률개선 AC/DC 컨버터)

  • Kim T.S;Koo G.B;Moon G.W.;Youn M.J
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.352-357
    • /
    • 2003
  • A new single stage power factor correction(PFC) AC/DC converter based on zero voltage switching(ZVS) full bridge topology is proposed. Since the series-connected two transformers act as both output inductor and main transformer by turns, the proposed converter has a wide ZVS range without additional devices for ZVS. Furthermore, since there is no need to use an output inductor, the proposed converter features high power density. The proposed converter gives the good power factor correction and low line current harmonics distortion. A mode analysis and experiment results are presented to verify the validity of the proposed converter.

  • PDF

Solid Oxide Fuel Cells for Power Generation and Hydrogen Production

  • Minh, Nguyen Q.
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Solid oxide fuel cells (SOFCs) have been under development for a variety of power generation applications. Power system sizes considered range from small watt-size units (e.g., 50-W portable devices) to very large multi-megawatt systems (e.g., 500-MW base load power plants). Because of the reversibility of its operation, the SOFC has also been developed to operate under reverse or electrolysis mode for hydrogen production from steam (In this case, the cell is referred to as solid oxide electrolysis cell or SOEC.). Potential applications for the SOEC include on-site and large-scale hydrogen production. One critical requirement for practical uses of these systems is long-term performance stability under specified operating conditions. Intrinsic material properties and operating environments can have significant effects on cell performance stability, thus performance degradation rate. This paper discusses potential applications of the SOFC/SOEC, technological status and current research and development (R&D) direction, and certain aspects of long-term performance degradation in the operation of SOFCs/SOECs for power generation/hydrogen production.

An analysis of the measured electric and magnetic fields of transmission lines in Korea (전국의 송전선로 전자계 측정치와 계산치와의 비교 분석)

  • Kim, S.B.;Cho, S.B.;Shin, K.Y.;Lee, D.I.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2368-2370
    • /
    • 1999
  • A nationwide survey for electric and magnetic fields(EMFs) near overhead transmission lines has been conducted. The median values of the electric and magnetic fields of 208 transmission lines were 0.50 kV/m and 12.6 mG, respectively. The maximum values were 3.16 kV/m and 125 mG. The measured EMFs were compared with the calculated ones. The causes of the discrepancy between measured and calculated EMFs are also discussed.

  • PDF