• Title/Summary/Keyword: G code

Search Result 856, Processing Time 0.027 seconds

Making Human Phantom for X-ray Practice with 3D Printing (3D 프린팅을 활용한 일반 X선 촬영 실습용 인체 팬텀 제작)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • General phantom for practical X-ray photography Practical phantom is an indispensable textbook for radiology, but it is difficult for existing commercially available phantom to be equipped with various kinds of phantom because it is an expensive import. Using 3D printing technology, I would like to make the general phantom for practical X-ray photography less expensive and easier. We would like to use a skeleton model that was produced based on CT image data using a 3D printer of FDM (Fused Deposition Modeling) method as a phantom for general X-ray imaging. 3D slicer 4.7.0 program is used to convert CT DICOM image data into STL file, convert it to G-code conversion process, output it to 3D printer, and create skeleton model. The phantom of the completed phantom was photographed by X - ray and CT, and compared with actual medical images and phantoms on the market, there was a detailed difference between actual medical images and bone density, but it could be utilized as a practical phantom. 3D phonemes that can be used for general X-ray practice can be manufactured at low cost by utilizing 3D printers which are low cost and distributed and free 3D slicer program for research. According to the future diversification and research of 3D printing technology, it will be possible to apply to various fields such as health education and medical service.

Evaluation of the Effective Width and Flexural Strength of the T-Stalled Walls (T형 벽체의 유효 폭 및 휨강도 평가)

  • 양지수;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.796-803
    • /
    • 2002
  • T-shaped walls have different strength, stiffness and ductility in the two opposite directions parallel to the web when subjected to horizontal in-plane loads. When the flange is in tension, the extent that the flange reinforcement contributes to the flexural strength will be subjected to shear-lag effect. Because of this shear-lag effect, the flange may not participate fully in the action with the web, and the effective flange width is needed for predicting the actual strength and stiffness of structures. The objective of this paper is to evaluate the effective flange width and actual strength of the T-shaped wall with Korean code specified detailing of the wall web. Three specimens were tested with cyclic lateral loading applied at top of the wall. A constant axial load of approximately 0.1f$\_$ck/$.$A$\_$g/ is maintained during the testing. Test results show that the effective flange width increases with increasing drift level, such that the entire overhanging flange of h/3 is effective at the maximum strength level. Therefore, the use of PCI or KBC(Korean Building Code) value of h/10 is unconservative with respect to detailing at the wall web boundary.

A Monte Carlo Study of Dose Enhancement with kilovoltage and megavoltage photons (몬테칼로 기법을 이용한 kV, MV X선에서의 선량증가 효과 비교 평가)

  • Hwang, ChulHwan;Im, In-Chul;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • Monte Carlo simulations were used to assess dose enhancement effects for 60-, 90-, 120-, and 150-kV X-rays, and for 6- and 15-MV X-rays. The MCNPX code was used for a computer simulation of the ICRU slab phantom, and gold, gadolinium, and iron oxide (Fe2O3) were employed as dose enhancement agents. In consideration of the buildup region of the incident energy, agent concentrations of 5, 10, 15, and 20 mg/g were inserted on the surface of the phantom at a depth of 5 cm. Based on baseline values obtained in the absence of dose enhancement agents, a quantitative analysis was performed by evaluating depth-dependent changes in the absorbed energy and the dose enhancement factor (DEF). A higher concentration of dose enhancement agents led to a greater dose enhancement effect with iron oxide, gadolinium, and gold in descending order. For kilovoltage (kV) X-rays, as the incident energy was decreased and as the energy became closer to the ionization potential of the atoms in the enhancement agent, the dose enhancement effect increased. In the megavoltage (MV) X-ray range, dose enhancement was higher at 6 MV compared with 15 MV. However, the overall dose enhancements were significantly lower compared to the results obtained with kV X-rays.

Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle (장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析))

  • Lee, Tae-Young;Ha, Chung-Woo;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.90-96
    • /
    • 1984
  • Estimated dose rates in spent fuel pool storage with the extended fuel cycle core management were reviewed and compared with design limit after calculation with the aid of DLC-23/CASK(22 n, 18 g) nuclear data and ANISN code. Radioactivity and gamma spectrum within spent fuel assemblies were calculated with ORIGEN code by extended fuel cycle model. In the calculation of dose rate, the fuel pool geometry was assumed to be infinite slab. Also, composition materials and radiation source within assemblies which are being stored in pool storage were assumed to be uniformly distributed throughout all the assemblies. As a result of culculation of dose rate from stored assemblies and waterborne radionuclides in pool water, the calculated dose rates appear to be lower than design basis limit under normal condition as well as abnormal condition.

  • PDF

Neutron fluence measurement at HANARO using fluence monitor method (Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정)

  • Lee, Seung-Kyu;Jo, Kwang-Ho;Choo, Kee-Nam;Park, Jin-Suk;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.200-208
    • /
    • 2011
  • The neutron fluence measurement and evaluation technology is very important for material irradiation test. The most essential technology in this study is the neutron irradiation evaluation method using a fluence monitor. The fluence monitors were fabricated with metal wires of the purity ${\geq}$ 99.9%, whose dimensions were 0.1mm diameter, about 3 mm length, and around 150-200 ${\mu}g$ mass range. Three wire samples (Fe, Ni, Ti) were prepared for one irradiation aluminum capsule. Five capsules were irradiated in the OR5 hole of the HANARO reactor at 30 MW power for about 25 days. After irradiation tests, radiation activities were measured with the high purity germanium (HPGe) detector. The reaction rates were calculated by using the measured radiation activity data, and then neutron fluence were obtained from the reaction rates and the weighted neutron cross section with calculated neutron spectrum at the fluence monitor position.

Shielding Performance of PLA and Tungsten Mixture using Research Extruder (연구용 압출기를 활용한 PLA와 텅스텐 혼합물의 차폐 성능)

  • Do-Seong Kim;Tae-Hyung Kim;Myeong-Seong Yoon;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 2023
  • In this study, 3D printing technology was used to compensate for the shortcomings of the use of lead, which has proven to have excellent shielding performance, and to control unnecessary human exposure. 3D printers can implement three-dimensional shapes and can immediately apply individual ideas, which has great advantages in maintaining technology supplementation while reducing the cost and duration of prototyping. Among the various special 3D printers, the FDM method was adopted, and the filament used for output was manufactured using a research extruder by mixing two materials, PLA (Poly-Lactic-Acid) and tungsten. The purpose was to verify the validity through dose evaluation and to provide basic information on the production of chapezones of various materials. The mixed filament was implemented as a morphological shield. Filaments made of a research extruder by mixing PLA and tungsten were divided into 10 %, 20 %, 30 %, 40 %, and 50 % according to the tungsten content ratio. Through the process of 3D Modeling, STL File storage, G-code generation, and output, 10 cm × 10 cm × 0.5 cm was manufactured, respectively, and dose and shielding ability were evaluated under the conditions of tube voltages of 60 kVp, 80 kVp, 100 kVp, 120 kVp, and tube currents of 20 mAs and 40 mAs.

Evaluation on Microbiological Contamination Level of Raw Beef from Retail Markets in Seoul, Korea (서울지역 식육판매점의 우육에 대한 미생물학적 오염도 평가)

  • Ko, Eun-Kyung;Heo, Eun Jeong;Kim, Young Jo;Park, Hyun Jung;Wi, Seong-Hwan;Moon, Jin San
    • Food Science of Animal Resources
    • /
    • v.33 no.3
    • /
    • pp.403-410
    • /
    • 2013
  • This study was performed to evaluate the microbiological contamination level of raw beef from retail markets in Seoul, Korea. The sampling and laboratory test were performed according to the procedure of "Standard for processing and ingredients specification of livestock product" and "Korean food code". Enterotoxin of Staphylococcus aureus isolates were detected using VIDAS$^{(R)}$ and PCR-based methods. Listeria monocytogenes serotyping and genotyping were carried out using Listeria antisera and L. monocytogenes Fingerprinting kit, respectively. A total of 48 samples were collected from 16 retail markets (butcher's shop: 5, department store: 6, supermarket: 5) in 2011. The level of total bacteria counts in the butcher's shop, department store and supermarket were $4.4{\times}10^3$ CFU/g, $3.9{\times}10^5$ CFU/g and $1.0{\times}10^4$ CFU/g, respectively. The concentrations of Escherichia coli of these three retail markets were $6.4{\times}10$ CFU/g, 7.6 CFU/g and $2.0{\times}10$ CFU/g, respectively. Salmonella species was not detected on all samples. However, S. aureus was isolated in the 3 samples (6.25%) from each type of three retail markets. L. monocytogenes was isolated in the 4 samples (8.3%) from department stores. The level of contamination of these foodborne bacteria was less than 100 CFU/g. The enterotoxin-encoding genes of S. aureus isolates were sea, seh, sei and sep gene. The gene similarity of L. monocytogenes isolated from two retail markets by Rep-PCR showed 57.8-98.1% and 68.1-98.1%, respectively. These results suggest that the HACCP guideline for environmental control in slaughterhouse and retail markets should be provided to prevent cross contamination and manage foodborne pathogens such as L. monocytogenes and S. aureus.

An Retrospective Analysis of 1549 patients under the Cooperative Medical Care consulted to the Department of Acupuncture and Moxibustion in a Korean medical hospital (한방병원 침구과로 협진의뢰된 한양방 협진 환자 1,549명에 대한 후향적 분석)

  • Jo, Hee Jin;Kwon, Min Soo;Kim, Jung Hwan;Jo, Dae Hyun;Choi, Ji Eun;Han, Ji Sun;Lee, Seung Hoon;Kim, Yong Suk;Nam, Sang Soo
    • Journal of Acupuncture Research
    • /
    • v.33 no.4
    • /
    • pp.109-119
    • /
    • 2016
  • Objectives : The aim of this study is to give a statistical basis for the characteristics of patients who received cooperative medical care after being referred from Western medical departments to the Department of Acupuncture and Moxibustion in a Korean medical hospital. Methods : The request records were searched for cooperative medical treatment at the Department of Acupuncture and Moxibustion in a Korean medical hospital between September 1st, 2011 and August 31, 2016, based on the Order Communication system(OCS). The records were reviewed and retrospectively analyzed according to the patient's general characteristics, the chief diagnosis code based on the 7th Korean standard classification of diseases(KCD-7) before and after the cooperative medical care in the Department of Acupuncture and Moxibustion, and the actual treatment measures which patients received as a result of the cooperative medical care. Results : Among the 2702 records, 1549 patients were included in the analysis. The male to female ratio was 1 : 1.17. Sexagenarians formed the highest age group and the number of patients whose age was over 50 was 1176(75.92 %). The surgery department requested the cooperative care from the department of Acupuncture and Moxibustion for the highest number of patients, 1194(77.08 %). When analysing specific medical departments, Neurosurgery, General Surgery, Neurology, Otorhinolaryngology, and Physical medicine and rehabilitation followed. The frequency of chief diagnosis code used before the cooperative medical care was in the order of I, C, G, S, and M code, from highest to lowest. The order of the codes after the cooperative medical care was the same. Acupuncture treatment was the most frequently-used measure after the cooperative medical care. Following were infrared, moxibustion, transfer, herbal acupuncture, cupping, electroacupuncture, and so on. Conclusion : This study provides a statistical basis for the demands placed on the Department of Acupunture and Moxibustion for cooperative medical care with the Western medical department. Based on the present condition of cooperative medical care, more preparation and effort is required for its activation.

Flow blockage analysis for fuel assembly in a lead-based fast reactor

  • Wang, Chenglong;Wu, Di;Gui, Minyang;Cai, Rong;Zhu, Dahuan;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3217-3228
    • /
    • 2021
  • Flow blockage of the fuel assembly in the lead-based fast reactor (LFR) may produce critical local spots, which will result in cladding failure and threaten reactor safety. In this study, the flow blockage characteristics were analyzed with the sub-channel analysis method, and the circumferentially-varied method was employed for considering the non-uniform distribution of circumferential temperature. The developed sub-channel analysis code SACOS-PB was validated by a heat transfer experiment in a blocked 19-rod bundle cooled by lead-bismuth eutectic. The deviations between the predicted coolant temperature and experimental values are within ±5%, including small and large flow blockage scenarios. And the temperature distributions of the fuel rod could be better simulated by the circumferentially-varied method for the small blockage scenario. Based on the validated code, the analysis of blockage characteristics was conducted. It could be seen from the temperature and flow distributions that a large blockage accident is more destructive compared with a small one. The sensitivity analysis shows that the closer the blockage location is to the exit, the more dangerous the accident is. Similarly, a larger blockage length will lead to a more serious case. And a higher exit temperature will be generated resulting from a higher peak coolant temperature of the blocked region. This work could provide a reference for the future design and development of the LFR.

Monitoring of Microorganism Contamination in Children-Preferred Confectioneries in Korea (서울·경인지역 유통판매중인 과자류의 위생지표 세균 및 식중독균 오염도 조사)

  • Koo, Eun Joo;Chung, So Young;Park, Ji Eun;Kwon, Yu Jihn;Seo, Dong Hyuk;Jung, Yu Young;Cho, Kyong Chul;Lee, Yo A;Min, Hee Eun;Kim, Eu Gene;Kim, Hyun Jung;Kim, Seul Ki;Choi, Sun Ok;Lim, Chul Ju
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.322-326
    • /
    • 2014
  • According to Centers for Disease Control and Prevention (CDC, USA) recently it was reported that the children (< 5 year-old children) were more susceptible to Foodborne-illness. Confectionery products should be strictly controlled because they are children-preferred foods. Ministry of Food and Drug Safety (MFDS, South of Korea) tried to monitor contamination of organisms in confectionery products (such as biscuits, candies, chewing gums and ice candies) distributed in South Korea. MFDS evaluated the levels of indicator organisms: total aerobic bacteria, coliforms, Escherichia coli as well as the levels of food-borne illness organisms: Staphylococcus aureus, Bacillus cereus, Clostridium perfringens. Experimental plans for microbiological test were in accordance with the International Commission on Microbiological Specifications for Food (ICMSF). For this study, 1,005 samples were collected and from Seoul and Gyeongin region, South Korea. The average level of total aerobic bacteria in 1,005 samples was 1.7 log Colony Forming Unit(CFU)/g and the detection rate was 26.8%. The average level of Bacillus cereus was detected in 1.7 log CFU/g and the rate was 0.9%. There was no detection of coliforms, Escherichia coli, Staphylococcus aureus and Clostridium perfringens. The results of this study will be provided as the basic data to set the reasonable microbiological criteria of Korea Food Code.