• Title/Summary/Keyword: Function generator

Search Result 704, Processing Time 0.026 seconds

Model-based localization and mass-estimation methodology of metallic loose parts

  • Moon, Seongin;Han, Seongjin;Kang, To;Han, Soonwoo;Kim, Munsung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.846-855
    • /
    • 2020
  • A loose part monitoring system is used to detect unexpected loose parts in a reactor coolant system in a nuclear power plant. It is still necessary to develop a new methodology for the localization and mass estimation of loose parts owing to the high estimation error of conventional methods. In addition, model-based diagnostics recently emphasized the importance of a model describing the behavior of a mechanical system or component. The purpose of this study is to propose a new localization and mass-estimation method based on finite element analysis (FEA) and optimization technique. First, an FEA model to simulate the propagation behavior of the bending wave generated by a metal sphere impact is validated by performing an impact test and a corresponding FEA and optimization for a downsized steam-generator structure. Second, a novel methodology based on FEA and optimization technique was proposed to estimate the impact location and mass of a loose part at the same time. The usefulness of the methodology was then validated through a series of FEAs and some blind tests. A new feature vector, the cross-correlation function, was also proposed to predict the impact location and mass of a loose part, and its usefulness was then validated. It is expected that the proposed methodology can be utilized in model-based diagnostics for the estimation of impact parameters such as the mass, velocity, and impact location of a loose part. In addition, the FEA-based model can be used to optimize the sensor position to improve the collected data quality in the site of nuclear power plants.

Validation of a Rodent Nose-only Exposure System for Inhalation Toxicity Evaluation of Cigarette Smoke (담배 흡입독성 평가를 위한 설치류 담배연기노출시스템의 유효화)

  • Sohn, Hyung-Ok;Lee, Hyeong-Seok;Shin, Han-Jae;Park, Chul-Hoon;Yoo, Ji-Hye;Jang, Mi;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.36 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • As part of a balanced testing battery, subchronic inhalation studies on rats are performed to ensure that proposed cigarette modifications do not increase the toxicity of smoke and to demonstrate any instances where a modification may actually contribute to harm reduction. For subchronic inhalation studies with aerosols, the OECD suggests an exposure regimen of 6 hours/day (OECD Guideline 413, 1981), but alternative regimens have also been published: 1 hour/day and $2{\times}1$ hour/day. The aim of this study was to validate a rodent nose-only exposure system for the assessment of inhalation toxicity of cigarette smoke. In this study, cigarette smoke exposure system is consisted of cigarette smoke generator, smoke concentration adjusting system, and 20-port nose-only exposure system. Male SD rats were exposed for 35 days ($2{\times}1$ hour/day) to 3R4F Reference cigarette smoke and analysed major monitoring items of OECD Gudeline 413. WTPM, was measured in the test atmosphere, respiratory function (Buxco Biosystems) during exposure, postexposure urinary exposure biomarkers and alveolar neutrophiles in BAL fluid (Day 35) were evaluated. Validation demonstrated steady WTPM ($257{\pm}20ug/L$, $502{\pm}27ug/L$) and spatial uniformity (<10%). Nose port temperature ($22{\sim}26^{\circ}C$ and RH (45~75%) were acceptable over 35 days. Reductions in respiratory rate and minute volume and increase in the neutrophiles in BALF and the urinary exposure biomarkers were observed cigarette smoke dose dependently. This validation and 35-day inhalation study has shown that the rodent nose-only exposure system may be useful in the inhalation toxicity assessment of cigarette smoke.

Pitch Angle Control of Wind Turbine based on Variable PID Gains (가변적인 PID 이득에 기초한 풍력발전 시스템의 피치제어)

  • Ko, Jung-Min;Yang, Soo-Youg;Boo, Chang-Jin;Kim, Ho-Chan;Huh, Jong-Chul;Lee, Junghoon;Kang, Min-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • For regulating generator speed above the rated wind, versatile methods have been published based on PID. However, these methods with the fixed PID gains could not guarantee that the controller works well in the whole area. In this paper, variable PID gain method has been suggested to overcome this problem. The sensitivity of power to blade pitch angle changes according to wind speed. The variable PID gain function has been derived from this sensitivity.

A Design of Ultra-sonic Range Meter Front-end IC (초음파 거리 측정회로용 프론트-엔드 IC의 설계)

  • Lee, Jun-Sung
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.1-9
    • /
    • 2010
  • This paper describes a ultrasonic signal processing front-end IC for distance range meter and body detector. The burst shaped ultrasonic signal is generated by a self oscillator and its frequency range is about 40[kHz]-300[kHz]. The generated ultrasonic signal transmit through piezo resonator. The another piezo device transduce from received ultrasonic signal to electrical signals. This front-end IC contained low noise amplifier, band pass filter, busrt detector and time pulse generator and so on. This IC has two type of new idea for improve function and performance, which are self frequency control (SFC) and Variable Gain Control amplifier (VGC) scheme. The dimensions and number of external parts are minimized in order to get a smaller hardware size. This device has been fabricated in a O.6[um] double poly, double metal 40[V] High Voltage CMOS process.

Developement of Electrical Load Testing System Implemented with Power Regenerative Function (회생전력 기능을 갖는 전기부하시험장치 개발)

  • Do, Wang-Lok;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 2016
  • The electrical load testing system developed from this study was designed to control rated-capacity-testing or variable-load-testing in an active and precise manner and save electric energy during testing, and also to convert the saved electric energy through the electrical load testing system to grid line. As for the device under testing, it was designed to be applied to not only transformer, rectifier, voltage regulator, inverter which require grid voltage source but, also applied to electric power, aerogenerator, photovoltaic, hybrid generator, battery, etc. which do not require grid voltage source. The system was designed to return the power consumed during the testing to the grid line by connecting the synchronizing pwm inverter circuit to the grid voltage source, and was also made to enable the being-tested system from disuse of approximately 93.4% energy when compared to the conventional load testing system which has used the passive resistor.

A Study of the Adaptive Control System (適應制御裝置에 關한 硏究)

  • Ha, Joo-Shik;Choi, Kyung-Sam;Kim, Seung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.19-31
    • /
    • 1979
  • Recently the adaptive control system, which keeps the control system always optimal by adjusting the control parameters automatically according to the variations of the plant parameters, have become very important in the field of control engineering. The adaptive control systems are usally composed of the plant identification, the decision of the optimal control parameters, and the adjustment of the control parameters. This paper deals with a method of the adaptive control system when PI or PID controller is used in the feed back control system. Its controlled object (the plant) is assumed to be described by the transfer function of $\frac{ke^{-LS}}{1+TS}$ where k, T and L are steady state gain, time constant and pure dead time respectively, and their values are variable in accordance with the change of environmental circumstance. It has been known that a pseudo-random binary signal is quite effective for the measurement of an impulse response of a plant. In adaptive control systems, however, the impulse response itself is not appropriate to determine the control parameters. In this paper, the authors propose a method to estimate directly the parameters of the plant k, T and L by means of the correlation technique using 3 level M-sequence signal as a test signal. The authors also propose a method to determine the optimal parameters of the PI or PID controller in the sense of minimizing the square integral of the control error in the feed back control system, and the values of the optimal parameters are computed numerically for various values of T and L, and the results are examined and compared with those of the conventional methods. Finally the above-mentioned two methods are combined and an algorithm to struct an adaptive control system is suggested. The experiments for the indicial responses by means of both the model of the temperature control system using SCR actuater and the analog simulations have shown good results as expected, and the effectiveness of the proposed method is verified. The M-sequence generator and the time delay circuit, which are manufactured for the experiments, are operated in quite a good condition.

  • PDF

Study on Real-Time Digital Filter Design as Function of Scanning Frequency of Focused Electron Beam (집속 전자 빔 장치에서 스캔 주파수에 따른 실시간 디지털 필터 설계에 관한 연구)

  • Kim, Seung-Jae;Oh, Se-Kyu;Yang, Kyung-Sun;Jung, Kwang-Oh;Kim, Dong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.479-485
    • /
    • 2011
  • To acquire images in a thermionic-scanning electron-beam system, a scanning unit is needed to control the electron beam emitted from the tungsten filament source. In scanning the electron beam on the solid surface, the signalto-noise ratio depends on the scanning frequency. We used a digital filter to reduce noise by analyzing the real-time frequency of a secondary electron signal. The noise and the true image signal were well separated. We designed the digital filter via a DSP floating-point operation, and the noise elimination resulted in enhanced image quality in a highresolution mode.

Vibration Characteristics of Corrugated Fiberboard Boxes for Packages of Pears (배 골판지 포장상자의 진동특성)

  • 김만수;정현모
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.391-398
    • /
    • 2002
  • During handling unitized products, they are subjected to a variety of environmental hazards. Shock and vibration hazards are generally considered the most damaging of the environmental hazards on a product and it may encounter while passing through the distribution environment. A major cause of shock damage to products is drops during manual handling. The increasing use of unitization of pallets has been resulted in a reduction of the shock hazards. This has caused an increasing interest in research focused on vibration caused dam age. Damage to the product by the vibration most often occurs when a product or a product component has a natural frequency that falls within the range of the forcing frequencies of the particular mode of transportation being used. Transportation vibration is also a major cause of fruit and vegetable quality loss due to mechanical damage. This study was conducted to determine the vibration characteristics of the corrugated fiberboard bones for packages of pears, and to investigate the degree of vibration injury of the pears in the boxes during the simulated transportation environment. The vibration tests were performed on an electrohydraulic vibration exciter. The input acceleration to exciter was fixed at 0.25 G for a single container resonance test and 0.5 G for the vertical stacked container over the frequency range from 3 to 100 Hz. Function generator (HP-33120A) was connected by wire to the vibration exciter for controlling the input acceleration at a continuous logarithmic sweep rate of 1.0 octave per min. The peak frequency and acceleration on the single box test were 22.02 Hz, 1.5425 G respectively, and these values on the vertical stacked boxes were observed from the bottom box 19.02, 18.14, 16.62 and 15.40 Hz and 2.2987, 3.7654. 5.6087, and 7.9582 G, respectively. The pear in the bottom box had a slightly higher damage level than the fruit packed in the other stacked boxes. It is desirable that the package and transportation system has to be so designed that 15∼20 Hz frequency will not occur during the transportation environment.

The Implementation of Load Resistance Measurement System using Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측방법을 이용한 부하 저항 측정 시스템 구현)

  • Kwak, Ki-Seok;Park, Tae-Geun;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.435-442
    • /
    • 2006
  • One of the most important topics about the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detecting and estimating of the fault on a wiring. In this paper, We've considered the load resistance measurement on a coaxial cable using TFDR in a way of expanded application. The TFDR system was built using commercial Pci extensions for Instrumentation(PXI) and LabVIEW. The proposed real time TFDR system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display part. To implement real time system, all of the parts were programmed by the LabVIEW which is one of the graphical programming languages. Using the application software implemented by the LabVIEW, we were able to design a proper reference signal which is suitable for target cable and control not only the arbitrary waveform generator in the signal generation part but alto the digital storage oscilloscope in the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we carried out load impedance measurement experiments. The experimental results showed that the proposed system are able not only to detect the location of impedance discontinuity on the cable but also to estimate the load resistance with high accuracy.

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria;Aro, Aapo L.;Alanko, Tommi;Lindholm, Harri;Sistonen, Heli;Hartikainen, Juha E.K.;Toivonen, Lauri;Juutilainen, Jukka;Hietanen, Maila
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.156-159
    • /
    • 2013
  • Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.