• Title/Summary/Keyword: Function generator

Search Result 704, Processing Time 0.024 seconds

An Analysis on Effects of Phase Compensation on Power System Stability in the PSS Parameter Tuning (PSS Tuning시 위상보상이 계통안정도에 미치는 영향 분석)

  • Kim, Tae-Kyun;Shin, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1147-1149
    • /
    • 1998
  • This paper presents the result of an analysis on effects of phase compensation on power system stability in the PSS parameter tuning. Synchronizing and damping coefficients are induced from lineal model for generator with PSS. Synchronizing and damping coefficients corresponding to time constants of phase compensation control block are calculated on a single machine, infinite bus test system. The Parameter tuning concepts, basic function, structural elements and performance criteria of PSS are introduced.

  • PDF

A Study on the Generating Algorithm and the Correlation Function of Kumar Code Sequences for the Frequency Hopping Patterns (주파수 경로 패턴을 위한 Kumar 부호계열 발생 알고리즘 및 상관함수 특성에 관한 연구)

  • 이정재;한영렬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.12
    • /
    • pp.1886-1902
    • /
    • 1989
  • In this paper we discuss the generating algorithm of Kumar code sequences which are based on generalized bent sequences for FH-CDMA. The code sequence generator was constructed for the shift register stages n=4 over GF (5). Finally we analyze the characteristics fo Hamming correlation between two code sequences and the time-frequency correlatins of the complete waveform with the sinusoidal chips as the elemental waveforms.

  • PDF

Study on the Calculation of the Optimal Power Operation Considering Line Contingencies (상정사고를 고려한 전력계통 최적운용에 관한 연구)

  • 박영문;백영식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.241-246
    • /
    • 1984
  • The power system scheduling process is formulated as an optimization problem with linear inequality constraints. AC Loadflow method is used for the problem solution and line losses are considered. The constraints under consiceration are generator power limits, load schedding limits and line capacity limits. In solving the objective function the Dual Relaxation method is adopted. Tests indicate that the method is practical for real time applications.

  • PDF

Wind Energy Charger Using Breaking and Power Conversation Switch (제동 및 전력변환 겸용 스위치를 이용한 풍력발전용 충전장치)

  • Ju, Hong-Ju;Lee, Hwa-Chun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.80-82
    • /
    • 2007
  • In this paper, we proposed new maximum electric power tracking algorithm by composing Buck-boost chopper circuit to charge electric power from wind energy generator which is under low and high wind velocity. The break function is also proposed with the existed buck-boost chopper switch. We made a proto-type as a lab level to verify appropriateness of using proposed circuit.

  • PDF

A Study on Implementation of Synchronous Ancillary System and UPS Function Using Generator (발전기를 이용한 동기조상기 및 UPS 기능구현에 관한 연구)

  • Choi, Hae-Sun;Kim, Byeong-Kak;Yang, Ji-Hoon;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.362-363
    • /
    • 2019
  • 비상발전기를 사용하여 무정전 시스템을 구성할 경우, 발전기 시스템이 정전을 인식하고 비상발전기의 기동하는 시간동안은 정전이 발생함으로 통상적으로 단주기 ESS와 결합한 UPS 시스템을 구축하게 된다. 이 경우 UPS 시스템 구축을 위한 ESS 시스템과 인버터에 대한 부담이 존재한다. 본 논문에서는 비상발전기와 엔진의 동력전달 부 사이에 플라이휠과 전자식 클러치에 의한 새로운 비상발전기 단독형 UPS 시스템을 제안한다.

  • PDF

Conversion Function and Relationship of Loss of Load Expectation Indices on Two Kinds of Load Duration Curve (두 종류의 부하곡선에 관한 공급지장시간기대치(LOLE)의 상호 변환관계성)

  • Lee, Yeonchan;Oh, Ungjin;Choi, Jaeseok;Cha, Junmin;Choi, Hongseok;Jeon, Donghun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.475-485
    • /
    • 2017
  • This paper develops a conversion function and method transforming from daily peak load curve used $LOLE_D$ [days/year] to hourly load curve used $LOLE_H$[hours/year]and describes relationship between $LOLE_D$ [days/year] and $LOLE_H$ [hours/year]. The indices can not only be transformed just arithmetically but also have different characteristics physically because of using their different load curves. The conversion function is formulated as variables of capacity and forced outage rate of generator, hourly load daily load factor and daily peak load yearly load factor, etc. Therefore, the conversion function (${\gamma}={\varphi}$(.)) can not be simple. In this study, therefore, the function is formulated as linear times of separated two functions. One is an exponential formed conversion function of daily load factor. Another is formulated with an exponential typed conversion function of daily peak load yearly load factor. Futhermore, this paper presents algorithm and flow chart for transforming from $LOLE_D$[days/year] to $LOLE_H$[hours/year]. The proposed conversion function is applied to sample system and actual KPS(Korea Power System) in 2015. The exponent coefficients of the conversion functions are assessed using proposed method. Finally, assessment errors using conversion function for case studies of sample system and actual system are evaluated to certify the firstly proposed method.

MEAC Method for Analysis of Power System Stability Improving Effect Considering Run-up SPS Function of HVDC (MEAC를 적용한 HVDC Run-up SPS의 안정도향상 효과분석)

  • Lee, Jae-Gul;Song, Ji-Young;Jang, Gil-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1454-1459
    • /
    • 2017
  • In spite of continuous increase of electric power demand and new generation plants, it is very difficult to install new transmission line. Therefore, it comes to be difficult to operate the power system stable, so it is required to find another way to get new transmission capacity. Because HVDC transmission system installation is the one of the best option for us, we have undertake the HVDC project in mainland. Buckdangjin-Goduck HVDC project(500kV, 3GW) is currently under construction and Eastern Power HVDC project(500kV, 8GW) is under the study for technical specification. Both of them have the Run-up SPS function for taking action of 765kV Transmission line fault. The Run-up SPS function increases the active power output of the HVDC rapidly when the transmission line between the power plant and network is tripped, thereby preventing the generator from overspeed and improving the power system stability. In this paper, we propose MEAC(Modified Equal Area Criteria) method based on traditional EAC method to quantitatively evaluate the effect of the HVDC run-up SPS function on the power system stability improvement.

Privacy Amplification of Quantum Key Distribution Systems Using Dual Universal Hush Function (듀얼 유니버셜 해쉬 함수를 이용한 양자 키 분배 시스템의 보안성 증폭)

  • Lee, Sun Yui;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This paper introduces the concept of a dual hash function to amplify security in a quantum key distribution system. We show the use of the relationship between quantum error correction and security to provide security amplification. Also, in terms of security amplification, the approach shows that phase error correction offers better security. We describe the process of enhancing security using the universal hash function using the BB84 protocol, which is a typical example of QKD. Finally, the deterministic universal hash function induces the security to be evaluated in the quantum Pauli channel without depending on the length of the message.

An Edge Detection Technique for Performance Improvement of eGAN (eGAN 모델의 성능개선을 위한 에지 검출 기법)

  • Lee, Cho Youn;Park, Ji Su;Shon, Jin Gon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.10 no.3
    • /
    • pp.109-114
    • /
    • 2021
  • GAN(Generative Adversarial Network) is an image generation model, which is composed of a generator network and a discriminator network, and generates an image similar to a real image. Since the image generated by the GAN should be similar to the actual image, a loss function is used to minimize the loss error of the generated image. However, there is a problem that the loss function of GAN degrades the quality of the image by making the learning to generate the image unstable. To solve this problem, this paper analyzes GAN-related studies and proposes an edge GAN(eGAN) using edge detection. As a result of the experiment, the eGAN model has improved performance over the existing GAN model.

Classification and recognition of electrical tracking signal by means of LabVIEW (LabVIEW에 의한 Tracking 신호 분류 및 인식)

  • Kim, Dae-Bok;Kim, Jung-Tae;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.779-787
    • /
    • 2010
  • In this paper, We introduce electrical tracking generated from surface activity associated with flow of leakage current on insulator under wet and contaminated conditions and design electrical tracking pattern recognition system by using LabVIEW. We measure the leaking current of contaminated wire by using LabVIEW software and the NI-c-DAQ 9172 and NI-9239 hardware. As pattern recognition algorithm and optimization algorithm for electrical tracking system, neural networks, Radial Basis Function Neural Networks(RBFNNs) and particle swarm optimization are exploited. The designed electrical tracking recognition system consists of two parts such as the hardware part of electrical tracking generator, the NI-c-DAQ 9172 and NI-9239 hardware and the software part of LabVIEW block diagram, LabVIEW front panel and pattern recognition-related application software. The electrical tracking system decides whether electrical tracking generate or not on electrical wire.