• Title/Summary/Keyword: Function Analysis Phase

Search Result 844, Processing Time 0.026 seconds

Wave propagation of functionally graded anisotropic nanoplates resting on Winkler-Pasternak foundation

  • Karami, Behrouz;Janghorban, Maziar;Tounsi, Abdelouahed
    • Structural Engineering and Mechanics
    • /
    • v.70 no.1
    • /
    • pp.55-66
    • /
    • 2019
  • This work deals with the size-dependent wave propagation analysis of functionally graded (FG) anisotropic nanoplates based on a nonlocal strain gradient refined plate model. The present model incorporates two scale coefficients to examine wave dispersion relations more accurately. Material properties of FG anisotropic nanoplates are exponentially varying in the z-direction. In order to solve the governing equations for bulk waves, an analytical method is performed and wave frequencies and phase velocities are obtained as a function of wave number. The influences of several important parameters such as material graduation exponent, geometry, Winkler-Pasternak foundation parameters and wave number on the wave propagation of FG anisotropic nanoplates resting on the elastic foundation are investigated and discussed in detail. It is concluded that these parameters play significant roles on the wave propagation behavior of the nanoplates. From the best knowledge of authors, it is the first time that FG nanoplate made of anisotropic materials is investigated, so, presented numerical results can serve as benchmarks for future analysis of such structures.

Free vibration and static analyses of metal-ceramic FG beams via high-order variational MFEM

  • Madenci, Emrah
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.493-509
    • /
    • 2021
  • There is not enough mixed finite element method (MFEM) model developed for static and dynamic analysis of functionally graded material (FGM) beams in the literature. The main purpose of this study is to develop a reliable and efficient computational modeling using an efficient functional in MFEM for free vibration and static analysis of FGM composite beams subject to high order shear deformation effects. The modeling of material properties was performed using mixture rule and Mori-Tanaka scheme which are more realistic determination techniques. This method based on the assumption that a two phase composite material consisting of matrix reinforced by spherical particles, randomly distributed in the beam. To explain the displacement components of the shear deformation effects, it was accepted that the shear deformation effects change sinusoidal. Partial differential field equations were obtained with the help of variational methods and then these equations were transformed into a novel functional for FGM beams with the help of Gateaux differential derivative operator. Thanks to the Gateaux differential method, the compatibility of the field equations was checked, and the field equations and boundary conditions were reflected to the function. A MFEM model was developed with a total of 10 degrees of freedom to apply the obtained functional. In the numerical applications section, free vibration and flexure problems solutions of FGM composite beams were compared with those predicted by other theories to show the effects of shear deformation, thickness changing and boundary conditions.

Numerical Analysis of Transitional Flow in a Stenosed Carotid Artery (협착된 경동맥내 천이 유동 수치 해석)

  • Kim, Dongmin;Hwang, Jinyul;Min, Too-Jae;Jo, Won-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.1
    • /
    • pp.52-63
    • /
    • 2022
  • Direct numerical simulation of blood flow in a stenosed, patient-specific carotid artery was conducted to explore the transient behavior of blood flow with special emphasis on the wall-shear stress distribution over the transition region. We assumed the blood as an incompressible Newtonian fluid, and the vessel was treated as a solid wall. The pulsatile boundary condition was applied at the inlet of the carotid. The Reynolds number is 884 based on the inlet diameter, and the maximum flow rate and the corresponding Womersley number is approximately 5.9. We found the transitional behavior during the acceleration and deceleration phases. In order to quantitatively examine the wall-shear stress distribution over the transition region, the probability density function of the wall-shear stress was computed. It showed that the negative wall-shear stress events frequently occur near peak systole. In addition, the oscillatory shear stress index was used to further analyze the relationship with the negative wall-shear stress appearing in the systolic phase.

Analysis of the Corporate Life Cycle using the Gompertz Model Focused on Korean Pharmaceutical Longevity Companies

  • Kyu-Jin, CHOI;Kang-Sun, LEE;Sung-Wook, KANG;Dae-Myeong, CHO
    • The Journal of Economics, Marketing and Management
    • /
    • v.11 no.1
    • /
    • pp.31-44
    • /
    • 2023
  • Purpose: This study aims to figure out the characteristics of corporate life cycle and resource input in terms of the sustainability diagnosis of pharmaceutical companies in Korea. Research design, data, and methodology: Using the Gompertz model under the assumption that companies have finite resources, this study tries quantitative interpretation of life cycle and resource input pattern for longevity companies with 25 years of experience among 158 pharmaceutical companies listed on Korean stock market based on maturity of revenue. Results: The study found revenue maturity through Gompertz model was statistically correlated with enterprise value. According to the life cycle analysis, more than 95% of 59 pharmaceutical companies were in the growth and maturity phase and have an average life cycle of 88 years and an average remaining life of 52 years. Regarding maturity profile of resource input, maturity of employees was generally high more than 60% and this meant there was jobless growth in Korean pharmaceutical industry. Conclusion: This study demonstrated there is a high statistical correlation between the maturity of a company's resource input and its revenue and enterprise value. It is believed that these results could be utilized as a basis for high fidelity function that predict revenue and enterprise value based on resource input information.

A novel aerodynamic vibration and fuzzy numerical analysis

  • Timothy Chen;Yahui Meng;Ruei-Yuan Wang;ZY Chen
    • Wind and Structures
    • /
    • v.38 no.3
    • /
    • pp.161-170
    • /
    • 2024
  • In recent years, there have been an increasing number of experimental studies showing the need to include robustness criteria in the design process to develop complex active control designs for practical implementation. The paper investigates the crosswind aerodynamic parameters after the blocking phase of a two-dimensional square cross-section structure by measuring the response in wind tunnel tests under light wind flow conditions. To improve the accuracy of the results, the interpolation of the experimental curves in the time domain and the analytical responses were numerically optimized to finalize the results. Due to this combined effect, the three aerodynamic parameters decrease with increasing wind speed and asymptotically affect the upper branch constants. This means that the aerodynamic parameters along the density distribution are minimal. Taylor series are utilized to describe the fuzzy nonlinear plant and derive the stability analysis using polynomial function for analyzing the aerodynamic parameters and numerical simulations. Due to it will yield intricate terms to ensure stability criterion, therefore we aim to avoid kinds issues by proposing a polynomial homogeneous framework and utilizing Euler's functions for homogeneous systems. Finally, we solve the problem of stabilization under the consideration by SOS (sum of squares) and assign its fuzzy controller based on the feasibility of demonstration of a nonlinear system as an example.

Amplitude and phase analysis of the brain Evoked Potential about performing a task related to visual stimulus using Empirical mode decomposition (경험적 모드 분해를 이용한 시각자극 관련 과제수행에 대한 뇌 유발전위 진폭과 위상 변화 분석)

  • Lee, ByuckJin;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • In this paper, amplitude and phase difference patterns for theta and alpha bands of the Evoked Potential(EP) in relation to perform a task at visual stimulus were analyzed using the Empirical mode decomposition(EMD). The EMD is applied to decompose EP signals with task-related sub-frequency band signals. Intrinsic mode function was implied in Hilbert transform and instantaneous amplitude and phase differences of theta and alpha were derived from Hilbert transformed EP. In a task status, large amplitude for both bands was observed at P2, N2, and P3 points as well as maximum phase difference was observed at N1 and P2. We confirmed that both bands are associated with a task at visual stimulus, and less associated with fixation. The proposed method enhances the time and frequency resolution in comparison with band-pass filter method which observed different phase results according to conditions.

The Relationship between the Serum Cytokine and Clinical Improvement in Major Depressive Disorder (주요 우울증에서 혈중 Cytokine과 임상적 호전과의 관계)

  • Kim, Hyon Chul;Lee, Sang Kyu;Kim, Do Hoon;Son, Bong Ki
    • Korean Journal of Biological Psychiatry
    • /
    • v.10 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • Object : Currently, the alteration of cytokine system has been known to play an important role in regard to depressive symptom. We focused on the relationship between immunological parameters and clinical improvement in major depressive disorder. Method : Data were collected on 26 patients with major depressive disorder using a 8-week prospective follow-up design. After 8-week treatment period with fluoxetine, patients were classified into a response group and a non-response group according to their psychopathological outcome as evaluated by Hamilton Depression Rating Scale. The differences of the immunological parameters between pre-treatment phase and post-treatment phase were compared among patients. The difference of those was also compared within each phase among them. The relationship between socio-demographic variables, depression, cytokine, mononuclear cells was examined by correlation analysis. Multiple regression analyses were performed to explore the predictors of clinical improvement of major depressive disorder. Result : Pre-treatment levels of IL-$1{\beta}$ in the response group were significantly higher than those in the non-response group. Pre-treatment levels of IL-$1{\beta}$ of all patients and in the response group were positively correlated with pre-treatment monocyte counts. Patients with subsequent remission showed significantly lower IL-6 values at baseline than those with non-response. Post-treatment values of IL-6 did not differ significantly among the patients. The correlation test showed more frequent relations among cytokines and mononuclear cells in the response group than in the non-responder group. Especially, serum level of IL-6 in pre-treatment phase was only significantly correlated with HAMD score after 8-week treatement phase, while other cytokines and mononuclear cells were not. Pretreatment level of IL-6 was of paramount importance in predicting clinical improvement of depressive symptom. Conclusion : The immune system of major depressive disorder patients might dichotomize the patients into subsequent responders and non-responders. Immune system might be of great influence on the clinical improvement of major depressive disorder. The mode of interaction between depression and cellular immune function and the mediators responsible for the cytokine production need to be studied further.

  • PDF

The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response (3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구)

  • Park, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.117-122
    • /
    • 2018
  • A large-capacity three-phase system air conditioner recently includes an inverter circuit to reduce power consumption. The inverter circuit uses a DC voltage that comes from DC-link power capacitor with the function of rectifying, which means AC voltage to DC voltage using a diode. An electrolytic capacitor is generally used to satisfy the voltage ripple and current ripple conditions of a DC-link power capacitor used for rectifying. Reducing the capacitance of the capacitor decreases the size, weight, and cost of the circuit. This paper proposes an algorithm to reduce the input ripple current by combining the minimum point estimation phase locked loop (PLL) phase control and the average voltage d axis current control technique. When this algorithm was used, the input ripple current decreased by almost 90%. The current ripple of the DC-link capacitor decreased due to the decrease in input ripple current. The capacitor capacity can be reduced but the electrolytic capacitor has a heat generation problem and life-time limitations because of its large equivalent series resistance (ESR). This paper proposes a method to select a film capacitor considering the current ripple at DC-link stage instead of an electrolytic capacitor. The capacitance was selected considering the voltage limitation, RMS (Root Mean Square) current capacity, and RMS current frequency analysis. A $1680{\mu}F$ electrolytic capacitor can be reduced to a $20{\mu}F$ film capacitor, which has the benefit of size, weight and cost. These results were verified by motor operation.

Analysis on Thermal Degradation of Poly($\gamma$-glutamic acid) Sodium Salt by means of Light Scattering and Viscometry (광산란과 점성도법에 의한 폴리감마글루탐산 나트륨 염의 열분해 분석)

  • Park, Il-Hyun;Eom, Hyo-Sang;Kwon, Hyo-Lee
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.501-508
    • /
    • 2009
  • The thermal degradation experiment of sodium salt of poly (${\gamma}$-glutamic acid) (PGGNa) has been carried out in both its solid phase and solution phase at the range of $57{\sim}120^{\circ}C$ and their molecular weight decreasing effect was analyzed as a function of time by means of viscometry and light scattering. Based on the solid phase degradation results, it was supposed that the bond scission rate in a polymer chain kept constant and that the bond scission was occurred on a randomly located position in a polymer chain. For the degradation in solution phase, it was also found that all data at various temperatures were dropped on a single master curve when the reduced time $t/t^*$ was used in the plot of the reciprocal intrinsic viscosity (or molecular weight). This degradation curve in solution phase could be expressed as the sum of a single exponential and a linear equation and especially, the single exponential character appeared only at the beginning stage. The activation energy was measured as $107{\sim}115$ kJ/mol in this study and agreed with the literature values.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.