• Title/Summary/Keyword: Fuel cycle

Search Result 1,817, Processing Time 0.021 seconds

CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO (하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석)

  • Cho, SungHwan;Lee, JongHyeon;Kim, DaeYoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.327-336
    • /
    • 2020
  • The high-flux advanced neutron application reactor (HANARO) is a research reactor with thermal power of 30 MW applied in various research and development using neutrons generated from uranium fission chain reaction. A degasifier tank is installed in the ancillary facility of HANARO. This facility generates gas pollutants produced owing to internal environmental factors. The degasifier tank is designed to maintain the gas contaminants below acceptable levels and is monitored using an analyzer in the gas sampling panel. If condensate water is generated and flows into the analyzer of the gas sampling panel, corrosion occurs inside the analyzer's measurement chamber, which causes failure. Condensate water is generated because of the temperature difference between the degasifier tank and analyzer when the gas flows into the analyzer. A heating system is installed between the degasifier tank and gas sampling panel to suppress condensate water generation and effectively remove the condensate water inside the system. In this study, we investigated the efficiency of the heating system. In addition, the variations in the pipe temperature and the amount of average condensate water were modeled using a wall condensation model based on the changes in the fluid inlet temperature, outside air temperature, and heating cable-setting temperature.

Simulation Study on Atmospheric Emission Scenarios of Radioxenon Produced by the North Korea's 6th Nuclear Test (북한 6차 핵실험으로 생성된 방사성제논의 대기 중 방출 시나리오에 대한 모의실험 연구)

  • Park, Kihyun;Min, Byung-Il;Kim, Sora;Kim, Jiyoon;Suh, Kyung-Suk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.261-273
    • /
    • 2020
  • North Korea conducted the sixth underground nuclear test on September 3, 2017 at the Punggye-ri Nuclear Test Site (NTS). In contrast to the previous five nuclear tests, several induced earthquakes occurred around the NTS after the sixth nuclear test and this may have caused radioxenon leakages at the site. Considering these reported earthquakes, we performed atmospheric dispersion simulations on some radioxenon emission scenarios for this event using our Lagrangian Atmospheric Dose Assessment System (LADAS) model by employing the Unified Model (UM) based numerical weather prediction data produced by the Korea Meteorological Administration (KMA). To find out possible detection locations and times, we combined not only daily and weekly based delayed releases but also leakages after the reported earthquakes around the NTS to create emission scenarios. Our simulation results were generally in good agreement with the measured data of the Nuclear Safety and Security Commission and International Monitoring System (IMS) stations operated by the Comprehensive nuclear Test-Ban-Treaty Organization (CTBTO).

Review of the Gross Alpha for Characterization of Radioactive Waste (방사성폐기물 특성평가를 위한 전알파 분석법 고찰)

  • Kim, Hyuncheol;Lim, Jong-Myoung;Jang, Mee;Park, Ji-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.227-235
    • /
    • 2020
  • In this study, we discussed the limitations of gross alpha measurements for the characterization of radioactive wastes produced in nuclear facilities through experimental tests and Monte Carlo N-particle transport simulations. The determination of gross alpha is essential for the disposal of radioactive waste produced in nuclear facilities in Korea. The measurements of gross alpha are easy to perform and yield rapid analytical results, but it cannot be used for quantitative analysis. The error of counting efficiency for gross alpha with various masses of the deposit on planchets using KCl and 241Am was determined. The relative deviation of the counting efficiency in samples having the same mass was 20%. Uranium was extracted from the soil through acid leaching and extraction chromatography, and the concentration of U determined by inductively coupled plasma-mass spectrometry (ICP-MS) was compared with the results for gross alpha. The gross alpha was underestimated by 50% compared to the U concentration by ICP-MS. The counting efficiency depended on the energy from the alpha emitters, which differed by up to three times in determination of the counting efficiency depending on the kinds of alpha radionuclides of interest. Therefore, the gross alpha is not compatible with the sum of radioactivity for each alpha emitter and is suitable as a screening method.

Safety Evaluation of Clearance of Radioactive Metal Waste After Decommissioning of NPP (원전해체후 규제해제 대상 금속폐기물에 대한 자체처분 안전성 평가)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Hwang, Young-Hwan;Lee, Mi-Hyun;Lee, Ji-Hoon;Hong, Sang-Bum
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.291-303
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled to be decommissioned after permanent shutdown, is expected to generate large amounts of various types of radioactive waste during the decommissioning process. Among these, nuclear reactors and internal structures have high levels of radioactivity and the dismantled structure must have the proper size and weight on the primary side. During decommissioning, it is important to prepare an appropriate and efficient disposal method through analysis of the disposal status and the legal restrictions on wastes generated from the reactors and internal structures. Nuclear reactors and internal structures generate radioactive wastes of various levels, such as medium, very low, and clearance. A radiation evaluation indicates that wastes in the clearance level are generated in the reactor head and upper head insulation. In this study, a clearance waste safety evaluation was conducted using the RESRAD-RECYCLE code, which is a safety evaluation code, based on the activation evaluation results for the clearance level wastes. The clearance scenario for the target radioactive waste was selected and the maximum individual and collective exposure doses at the time of clearance were calculated to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. The evaluation results indicated that the doses were significantly low, and the clearance criteria were satisfied. Based on the safety assessment results, an appropriate metal recycle and disposal method were suggested for clearance, which are the subject of the deregulation of internal structures of nuclear power plant.

The Assessment of Exposure Dose of Radiation Workers for Decommissioning Waste in the Radioactive Waste Inspection Building of Low and Intermediate-Level Radioactive Waste Disposal Facility (경주 중·저준위방사성폐기물 처분시설의 방폐물검사건물에서 해체 방사성폐기물 대상 방사선작업종사자의 피폭선량 평가 및 작업조건 도출)

  • Kim, Rin-Ah;Dho, Ho-Seog;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.317-325
    • /
    • 2020
  • The Korea Radioactive Waste Agency plans to expand the storage capacity of radioactive waste by constructing a radioactive waste inspecting building to solve the problem of the lack of inspection space and drum-handling space in the radioactive waste receipt and storage building for the first-stage disposal facility. In this study, the exposure doses of radiation workers that handle new disposal containers for decommissioning waste in the storage areas of the radioactive waste inspecting building were calculated using the Monte Carlo N-particle transport code. The annual collective dose was calculated as a total of 84.8 man-mSv for 304 new disposal containers and an estimated annual 306 working hours for the radiation work. When the 304 new disposal containers (small/medium type) were stored in the storage areas, it was found that 25 radiation workers should be involved in acceptance/disposal inspection, and the estimated exposure dose per worker was calculated as an average annual value of 3.39 mSv. When the radiation workers handle the small containers in high-radiation dose areas, the small containers should be shielded further by increasing the concrete liner thickness to improve the work efficiency and radiation safety of the radiation workers. The results of this study will be useful in establishing the optimal radiation working conditions for radiation workers using the source term and characteristics of decommissioning waste based on actual measurements.

Method for Evaluating Radionuclide Transport in Biosphere by Calculating Elapsed Transport Time (이동 경과 시간 계산을 이용한 생물권에서의 방사성 핵종 이동 평가 방법)

  • Ko, Nak-Youl;Ji, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.305-315
    • /
    • 2020
  • For geological disposal of radioactive wastes, a method was proposed to evaluate the radionuclide transport in the biosphere by calculating the elapsed time of nuclide migration. The radionuclides were supposed to be introduced from a natural barrier and reached a large surface water body following a groundwater flow in a shallow subsurface. The biosphere was defined as a shallow subsurface environment that included aquifers on a host rock. Using the proposed method, a calculation algorithm was established, and a computer code that implemented the algorithm was developed. The developed code was verified by comparing the simulation results of the simple cases with the results of the analytical solution and a public program, which has been widely used to evaluate the radiation dose using the radionuclide transport near the surface. A case study was constructed using the previous research for radionuclide transport from the hypothetical geological disposal repository. In the case study, the code calculated the mass discharge rate of radionuclide to a stream in the biosphere. Because the previous research only demonstrated the transport of radionuclides from the hypothetical repository to the host rock, the developed code in the present study could help identify the total transport of radionuclide along the complete pathway.

Sample pre-treatment for measurement of $^{129}$I in radwastes (방사성폐기물 중 $^{129}$I 측정을 위한 시료의 전처리)

  • Ke Chon Choi;Sun Ho Han;Jee Kwang Yong;Ki Seop Choi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Many different kinds of radwastes are discharged from the nuclear power plants, and $^{129}$I is included in these radwastes. Recovery test of $^{129}$I was evaluated for different radwastes(dry active waste, sludge, spent resin and simulated evaporator bottom). Recovery of $^{129}$I for dry active waste by acid leaching with $1.8\%$ NaClO was $74.3\%$$(RSD,\;2.2\%)$ and l291 for spent rein by alkali fusion method with KOH as a flux agent was $87.7\%$$(RSD,\;0.9\%$), respectively. iodide in simulated evaporator bottom containing a high concentration of borate was adsorbed with anion exchange resin at pH 7 phosphate buffer solution. Recovery of $^{129}$I for anion exchange resin was $92.5\%$ and not affected up to 1,200 $\mu$g/mL $H_3BO)3$(as a Boron). Recovery of $^{129}$I for the spent resin from nuclear power plant was $87.2\%$ $(RSD,\;1.2\%)$.

  • PDF

Application of Cyclone to Removal of Hot Particulate in Hot Cell (Hot Cell 내의 고방사능 분진 제거를 위한 사이클론 적용 실험)

  • Kim Gye Nam;Lee Sung Yeol;Won Hui Jun;Jung Chong Hun;Oh Won Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.67-75
    • /
    • 2005
  • The size and main ingredient of hot particulate generated during the nuclide experiment in hot cells of nuclear facilities were 0.5300 $\mu$m and UO$\_2$. A cyclone filter equipment which consists of a cyclone and Bag/HEPA filter was devised to remove hot particulate generated during the nuclide experiment in hot cells of nuclear facilities. The experimental conditions to maximize the collection efficiency of hot particulate were suggested through experiments done with the cyclone filter equipment. With the large size of simulated particulate, the collection efficiency of the particulate was high. When the size of simulated particulate was more than 5 $\mu$m, the collection efficiency of the particulate was more than $80\%$ and when the size of simulated particulate was less than 1.0 urn, the collection efficiency decreased by less than $70\%$. If the inflow velocity of simulated particulate was increased, the collection efficiency of the particulate was also increased. When the inflow velocity of simulated particulate was more than 12m/sec, the collection efficiency was higher than $70\%$, but after 17 m/sec inflow velocity, no change observed. The collection efficiency of the simulated particulate can be enhanced with the length of vortex finder inside the chamber. With the length of vortex finder, 7.2cm, the observed collection efficiency of the particulate was the maximum. Moreover, when the sub-cone was attached under the cyclone, the collection efficiency of cyclone increased $2\%$. It was found that effect by attachment of sub-cone was not serious.

  • PDF

Conceptual Geochemical Modelling of Long-term Hyperalkaline Groundwater and Rock Interaction (지구화학 모델을 이용한 장기간의 강알칼리성 지하수-암석의 반응 개념 모델링)

  • Choi, Byoung-Young;Yoo, Si-Won;Chang, Kwang-Soo;Kim, Geon-Young;Koh, Yong-Kwon;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.273-281
    • /
    • 2007
  • Hyperalkaline groundwater formed by groundwater-cement components and its reaction with bedrock in a nuclear waste repository were simulated by geochemical modeling. The result of groundwater-cement components reaction showed that the pH of water was 13.3 and the precipitated minerals were Brucite, Katoite, Calcium Silicate Hydrate(CSH1.1), Ettringite, Hematite, and Portlandite. The result of interaction between such minerals and groundwater sampled in Gyeongju area also showed that the pH of groundwater reached 12.4. Interaction between such hyperalkaline groundwater and granite was simulated by kinetic model during $10^3$ years. This result showed that the final pH of groundwater reached 11.2 and the variation of pH was controlled by dissolution/precipitation of silicate and CSH minerals. Groundwater quality was also determined by dissolution/precipitation of silicate, CSH, oxide minerals. Our results show that geochemical modeling of long-term hyperalkaline groundwater and rock interaction can contribute to the safety assessment of engineered barrier by predicting geochemical condition in repository site.

  • PDF

Separation and Recovery for the Analysis of Radioiodine in RI Wastes (RI 폐기물 내 방사성요오드 분석을 위한 분리 및 회수)

  • Kang, Sang-Hoon;Han, Sun-Ho;Lee, Heung-N.;Jee, Kwang-Yong;Lee, In-Koo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.267-272
    • /
    • 2007
  • Various kinds of RI wastes are discharged from licensed organizations of radioisotopes les such as hospitals and clinic organizations, educational organizations, research institutions, and public organizations. Radioiodines such as $^{125}I\;and\;^{131}I$ are radioisotopes mainly used in nuclear medicine and industry. A method for the determination of radioiodines in RI wastes has been applied to measure low level activity using acid decomposition method and HPGe gamma ray spectrometer. Prior to analysis of real samples, $^{131}I$ reference solution and 10 g of yellow tissue paper was added to flask in mantle and was heated in 100 mL of 0.4 N $K_2Cr_2O_7$ and 100 mL of 9 M $H_2SO_4$, and then distilled after adding 10 mL of 30% $H_2PO_3$ and 1 mL of 30% $H_2O_2$. The condensed iodine by circulator was extracted into $CCl_4$, then back-extracted into the aqueous phase with 10 mL of 5% $K_2SO_2$ solution. Finally, $^{131}I$ was measured at 364.48 keV using HPGe gamma ray spectrometer after precipitation and filtration. Chemical yield of three steps such as acid decomposition process, chemical separation process, and precipitation and filtration process was more han 94% respectively, MDA(Minimum Detectable Activity) of $^{131}I$ at this analytical condition was 0.6 Bq/g.

  • PDF