• 제목/요약/키워드: Fuel consumption reduction

검색결과 328건 처리시간 0.038초

도시지역 고정식 신호체계의 효율적 운영 ( The Efficient Operations of the Pretimed Signal System ( PSS ) in Urban Area )

  • Kim, T.G.
    • Journal of Korean Port Research
    • /
    • 제10권2호
    • /
    • pp.91-101
    • /
    • 1996
  • Today transportation problems are severer with the increase of the vehicles and travel demand in urban areas, but could not be completely solved with only the expansion of the new transportation facilities. Because the expansion of the new transportation facilities are limited in urban areas. As one of the Transportation System Management(TSM) techniques in this study, the simulation results of the existing signal systems which were operated based upon the peak time periods for increasing the efficiency on the pretimed signalized intersections(PSI) during the different time periods : the AM on-Peak, the AM off-Peak, the PM off-Peak, and the PM on-Peak, were as follows : i) There was no distinct difference in the total traffic volumes concentrated on the signalized intersections during the different time periods, but a considerably big difference in the directional traffic volumes for those time periods. ii) There were about 53% reduction of the average delay and 51% reduction of the fuel consumption when applying the different signal systems to the different time periods regardless of the CBD and Non-CBD. iii) There were about 36% increase of the average delay and 33% increase of the fuel consumption when applying the same signal systems during the peak time periods to the different time periods regardless of the CBD and Non-CBD. Based on the above results, it was concluded that constructing the different signal systems for the different time periods would be better than construction the same ones for those periods on the pretimed signalized intersections in urban areas.

  • PDF

Study on the Thermal Characteristics of Concrete Using Micro Form Admixture (마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구)

  • Park, Young Shin;Kim, Jung Ho;Jeon, Hyun Kyu;Seo, Chee Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. So, various actions to reduce greenhouse gas exhaustion and energy consumption have been prepared by world developed countries. Our government has also been trying to seek energy control methods for houses and buildings by proclaiming political polices on low-carbon green growth and construction and performance standards for environment-friendly housing. The energy consumption by buildings approximately reaches 25% of total korea energy consumption, and the increasing rate of energy consumption by buildings is stiffer than the rate by the other industries. The greatest part in the buildings of the energy consumption is building facade. While lots of research projects for reducing energy consumption of the facade have been conducted, but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research presents here a study to improve the insulation property of structural concrete formed by micro form admixture (MFA) with experimentally reviewing the physical, mechanical and thermal characteristics of the concrete. As the results of this experiment, in the case of concrete mixed with MFA, slump loss has been improved. As the mixing ratio of MFA increases, the compressive strength is decreased and thermal conductivity is increased. Also it was found that water-cement ratio increases, the compressive strength is decreased and thermal conductivity is increased. but, there was not big influence by the change of fine aggregate ratio.

CO2 Emission Analysis from Horticultural Facilities & Agricultural Machinery for Spread of New and Renewable Energy in Rural-type Green Village (농촌형 녹색마을에 신재생에너지 보급을 위한 시설재배 및 농업기계의 CO2 배출량 분석)

  • Kim, J.G.;Ryou, Y.S.;Kang, Y.K.;Kim, Y.H.;Jang, J.K.;Kim, H.T.;Seo, K.W.;Lee, S.K.;Cho, H.J.;Kang, J.W.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • 제19권1호
    • /
    • pp.86-92
    • /
    • 2011
  • In order to reduce dependence on the fossil fuels and $CO_2$ gas emission in farming activities, the government has pushed ahead with making the self-sufficiency of farming energy up 40% level in green villages. The objectives of this study are to survey the energy consumption of horticultural facilities or agricultural machineries, and to analyze the reduced $CO_2$ gas emission level from fossil fuel to bio-diesel fuel. For the implement of this study, it is necessary to analyze the energy consumption level in the various sector of farming activities, and available renewable energy sources should be selected. Annual total $CO_2$ gas emission in the tillage farming sector was analyzed as $5,667,258\;t-CO_2$ and that in the horticultural facilities occupied $4,932,607\;t-CO_2$, while the $CO_2$ gas emission level of diesel fuel was $3,105,707\;t-CO_2$, and that of the heavy oil showed $1,370,578\;t-CO_2$. The average $CO_2$ gas emission level of horticultural facilities in the country was analyzed as $29,418\;t-CO_2/ha$. Among the total energy consumption of agricultural machineries, tractor used 284,763kL, power tiller spent 221,314 kL, grain drier consumed 145,524kL and combine tractor expend 72,537kL. From the comparison of $CO_2$ gas emission level between fossil fuel and bio-diesel fuel for the horticultural facilities or agricultural machinery in G-City, Jeonbuk Province, the $CO_2$ gas emission level can be reduced by 7% through replacing the fuel from fossil to biodiesel.

A preliminary study of pilot-scale electrolytic reduction of UO2 using a graphite anode

  • Kim, Sung-Wook;Heo, Dong Hyun;Lee, Sang Kwon;Jeon, Min Ku;Park, Wooshin;Hur, Jin-Mok;Hong, Sun-Seok;Oh, Seung-Chul;Choi, Eun-Young
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1451-1456
    • /
    • 2017
  • Finding technical issues associated with equipment scale-up is an important subject for the investigation of pyroprocessing. In this respect, electrolytic reduction of 1 kg $UO_2$, a unit process of pyroprocessing, was conducted using graphite as an anode material to figure out the scale-up issues of the C anode-based system at pilot scale. The graphite anode can transfer a current that is 6-7 times higher than that of a conventional Pt anode with the same reactor, showing the superiority of the graphite anode. $UO_2$ pellets were turned into metallic U during the reaction. However, several problems were discovered after the experiments, such as reaction instability by reduced effective anode area (induced by the existence of $Cl_2$ around anode and anode consumption), relatively low metal conversion rate, and corrosion of the reactor. These issues should be overcome for the scale-up of the electrolytic reducer using the C anode.

Study on the Performance Characteristics of Urea-SCR System in the ETC Test (ETC 모드에서 Urea-SCR 시스템의 성능 특성 연구)

  • Ham, Yun-Young;Choi, Dong-Seok;Park, Yong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제18권2호
    • /
    • pp.122-128
    • /
    • 2010
  • To meet the NOx limit without a penalty of fuel consumption, urea-SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, the performance characteristics of urea-SCR system with open loop control were assessed in the European Transient Cycle(ETC) for heavy duty diesel engine. The SCR inlet temperaure varied in the range of 200 to $340^{\circ}C$ in the ETC cycle. Open loop control calculated the urea flow rate based on the NOx and NSR map which gave for each combination of SCR inlet temperature and space velocity the normalized $NH_3$ to NOx stoichiometric ratio which resulted in a steady-state $NH_3$ slip of 20ppm. During the ETC cycle, the open loop control with the optimized NSR offset achieved NOx reduction of 80% while keeping the average $NH_3$ slip below 10ppm and maximum 20ppm. It was also found that NOx sensor was cross-sensitive to $NH_3$ and a control strategy for cross-sensitivity compensation was required in order to use a NOx sensor as feedback device.

Proposal of a Pilot Plant (2T/day) for Solid Fuel Conversion of Cambodian Mango Waste Using Hybrid Hydrothermal Carbonization Technology (하이브리드 수열탄화기술을 이용한 캄보디아 망고 폐기물 고형연료화 실증플랜트 (2T/day) 제안)

  • Han, Jong-il;Lee, Kangsoo;Kang, Inkook
    • Journal of Appropriate Technology
    • /
    • 제7권1호
    • /
    • pp.59-71
    • /
    • 2021
  • Hybrid hydrothermal carbonization (Hybrid HTC) technology is a proprietary thermochemical process for two or more organic wastes.The reaction time is less than two hours with temperature range 180~250℃ and pressure range 20~40bar. Thanks to accumulation of the carbon of the waste during Hybrid HTC process, the energy value of the solid fuel increases significantly with comparatively low energy consumption. It has also a great volume reduction with odor removal effect so that it is evaluated as the best solid fuel conversion technology for various organic wastes. In this study of the hybrid hydrothermal carbonization, the effect on the calorific value and yield of Cambodian mango waste were evaluated according to changes in temperature and reaction time. Through the study, parameter optimization has been sought with improving energy efficiency of the whole plant. It is decomposed in the Hydro-Carbonation Technology to Generate Gas. At this time, it is possible to develop manufacturing and production technologies such as hydrogen (H2) and methane (CH4). Based on the results of the study, a pilot plant (2t/day) has been proposed for future commercialization purpose along cost analysis, mass balance and energy balance calculations.

Effect of economic growth, industrial structure, efficiency improvement, decarbonization of power sector and fuel substitution for the transition to low carbon society by 2050 (2050년 저탄소 사회로의 전환을 위한 경제성장, 산업구조, 효율개선, 전력 탈탄소화와 연료 대체의 효과)

  • Park, Nyun-Bae;Hong, Sungjun;Park, Sang Yong
    • Journal of Energy Engineering
    • /
    • 제23권4호
    • /
    • pp.61-72
    • /
    • 2014
  • This paper analyzed transition pathways toward a low carbon society in Korea to meet global $2^{\circ}C$ climate target. Lower economic growth, industrial structure change, enhance of energy demand management, decarbonization of power sector, and replacement of low carbon fuel could reduce greenhouse gas (GHG) emission from fuel combustion in 2050 by 67% against in 2011, or by 74% against in BAU (Business-As-Usual). Lower economic growth contributes to 13% of cumulative emission reduction relative to BAU, industrial structure change 9%, enhance of energy demand management 72%, decarbonization of power sector 5% and replacement of low carbon fuel 1% respectively. Final energy consumption in 2050 needs to be reduced to 50% relative to 2011, or to 41% relative to BAU. Nuclear, coal and renewable energy represent 31%, 40%, 2% respectively among electricity generation in 2011, but 38%, 2%, 32% in 2050. CCS represents 23% of total generation in 2050. Emission intensity of electricity in 2050 was decreased to 19% relative to 2011, or to 24% relative to BAU. Primary energy in 2050 was decreased to 64% compared to 2011, or to 44% compared to BAU. Final energy consumption, primary energy supply and GHG emission from fuel combustion from 1990 to 2011 increased by 176%, 197%, 146%. Radical change from historical trend is required to transit toward a low carbon society by 2050. Appropriate economic growth, structural change to non-energy intensive industries, energy technology research, development and deployment (RD&D) in terms of enhancement of energy efficiency and low carbon energy supply technologies, and fuel change to electricity and renewable energy are key instruments.

Accuracy and applicable range of a reconstruction technique for hybrid rockets

  • Nagata, Harunori;Nakayama, Hisahiro;Watanabe, Mikio;Wakita, Masashi;Totani, Tsuyoshi
    • Advances in aircraft and spacecraft science
    • /
    • 제1권3호
    • /
    • pp.273-289
    • /
    • 2014
  • Accuracy of a reconstruction technique assuming a constant characteristic exhaust velocity ($c^*$) efficiency for reducing hybrid rocket firing test data was examined experimentally. To avoid the difficulty arising from a number of complex chemical equilibrium calculations, a simple approximate expression of theoretical $c^*$ as a function of the oxidizer to fuel ratio (${\xi}$) and the chamber pressure was developed. A series of static firing tests with the same test conditions except burning duration revealed that the error in the calculated fuel consumption decreases with increasing firing duration, showing that the error mainly comes from the ignition and shutdown transients. The present reconstruction technique obtains ${\xi}$ by solving an equation between theoretical and experimental $c^*$ values. A difficulty arises when multiple solutions of ${\xi}$ exists. In the PMMA-LOX combination, a ${\xi}$ range of 0.6 to 1.0 corresponds to this case. The definition of $c^*$ efficiency necessary to be used in this reconstruction technique is different from a $c^*$ efficiency obtained by a general method. Because the $c^*$ efficiency obtained by average chamber pressure and ${\xi}$ includes the $c^*$ loss due to the ${\xi}$ shift, it can be below unity even when the combustion gas keeps complete mixing and chemical equilibrium during the entire period of a firing. Therefore, the $c^*$ efficiency obtained in the present reconstruction technique is superior to the $c^*$ efficiency obtained by the general method to evaluate the degree of completion of the mixing and chemical reaction in the combustion chamber.

Turret location impact on global performance of a thruster-assisted turret-moored FPSO

  • Kim, S.W.;Kim, M.H.;Kang, H.Y.
    • Ocean Systems Engineering
    • /
    • 제6권3호
    • /
    • pp.265-287
    • /
    • 2016
  • The change of the global performance of a turret-moored FPSO (Floating Production Storage Offloading) with DP (Dynamic Positioning) control is simulated, analyzed, and compared for two different internal turret location cases; bow and midship. Both collinear and non-collinear 100-yr GOM (Gulf of Mexico) storm environments and three cases (mooring-only, with DP position control, with DP position+heading control) are considered. The horizontal trajectory, 6DOF (degree of freedom) motions, fairlead mooring and riser tension, and fuel consumptions are compared. The PID (Proportional-Integral-Derivative) controller based on LQR (linear quadratic regulator) theory and the thrust-allocation algorithm which is based on the penalty optimization theory are implemented in the fully-coupled time-domain hull-mooring-riser-DP simulation program. Both in collinear and non-collinear 100-yr WWC (wind-wave-current) environments, the advantage of mid-ship turret is demonstrated by the significant reduction in heave at the turret location due to the minimal coupling with pitch mode, which is beneficial to mooring and riser design. However, in the non-collinear WWC environment, the mid-turret case exhibits unfavorable weathervaning characteristics, which can be reduced by employing DP position and heading controls as demonstrated in the present case studies. The present study also reveals the plausible cause of the failure of mid-turret Gryphon Alpha FPSO in milder environment than its survival condition.

RPSMDSM: Residential Power Scheduling and Modelling for Demand Side Management

  • Ahmed, Sheeraz;Raza, Ali;Shafique, Shahryar;Ahmad, Mukhtar;Khan, Muhammad Yousaf Ali;Nawaz, Asif;Tariq, Rohi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권6호
    • /
    • pp.2398-2421
    • /
    • 2020
  • In third world countries like Pakistan, the production of electricity has been quickly reduced in past years due to rely on the fossil fuel. According to a survey conducted in 2017, the overall electrical energy capacity was 22,797MW, since the electrical grids have gone too old, therefore the efficiency of grids, goes down to nearly 17000MW. Significant addition of fossil fuel, hydro and nuclear is 64.2%, 29% and 5.8% respectively in the total electricity production in Pakistan. In 2018, the demand crossed 20,223MW, compared to peak generation of 15,400 to 15,700MW as by the Ministry of Water and Power. Country faces a deficit of almost 4000MW to 5000MW for the duration of 2019 hot summer term. Focus on one aspect considering Demand Side Management (DSM) cannot oversea the reduction of gap between power demand and customer supply, which eventually leads to the issue of load shedding. Hence, a scheduling scheme is proposed in this paper called RPSMDSM that is based on selection of those appliances that need to be only Turned-On, on priority during peak hours consuming minimum energy. The Home Energy Management (HEM) system is integrated between consumer and utility and bidirectional flow is presented in the scheme. During peak hours of electricity, the RPSMDSM is capable to persuade less power consumption and accomplish productivity in load management. Simulations show that RPSMDSM scheme helps in scheduling the electricity loads from peak price to off-peak price hours. As a result, minimization in electricity cost as well as (Peak-to-Average Ratio) PAR are accomplished with sensible waiting time.