• 제목/요약/키워드: Frost thickness

검색결과 76건 처리시간 0.026초

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreeze Solution

  • Chang Young-Soo;Yun Won-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.66-75
    • /
    • 2006
  • The effect of antifreeze solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreeze solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation while having small thermal resistance across the film. A porous layer coating technique is adopted to improve the wettability of the antifreeze solution on a parallel plate heat exchanger. The antifreeze solution spreads widely on the heat exchanger surface with $100{\mu}m$ thickness by the capillary force resulted from the porous structure. It is observed that the antifreeze solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by the thin liquid film are only $1{\sim}2%$ compared with those for non-liquid film surface.

수치해석을 통한 강원지역 도로터널 라이닝 배면지반의 동결깊이 분석 (Numerical Analysis of Frost Depth behind the Lining of Road Tunnel in Gangwon Province)

  • 손희수;전경재;윤찬영
    • 한국지반환경공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.15-23
    • /
    • 2017
  • 강원지역은 한국의 북동부에 위치하고 있으며 산지가 90%에 달해 한국에서 가장 추운 지역이다. 그에 따라 겨울철 터널 피해가 지속적으로 발생하고 있으나 아직 터널 라이닝 배면에서 발생하는 동상에 대한 연구는 매우 부족하다. 본 연구에서는 강원지역의 도로터널에서 발생하는 동상깊이 분석을 위한 수치적 연구를 수행하였다. 강원지역 도로터널 현황과 기후자료를 분석하고 이를 토대로 터널 표준 형상과 지반 특성을 가정하였으며, 기온 변화와 지반특성 변화에 따른 터널 배면지반의 최대 동상깊이를 산정하였다. 해석결과 모래보다 변성암 및 퇴적암의 동결민감성이 더 크며, 라이닝 배면의 초기 지중온도가 낮을수록 동상깊이가 깊어져 동결에 대한 피해도 커지는 것으로 나타났다. 또한 라이닝 두께 및 지반의 비열, 열전도율과 같은 특성도 동결깊이 변화에 큰 영향을 미치는 것으로 나타났다.

현장도로 모형실험을 이용한 포장구성층의 동결 특성 분석 (The Freezing Characteristics of Pavement Layer Using the Field Road Model Test)

  • 신은철;류병현;박정준
    • 한국지반공학회논문집
    • /
    • 제26권7호
    • /
    • pp.71-80
    • /
    • 2010
  • 지리학적 특성으로 국내는 계절 동토지역으로 겨울철에는 동상현상이 발생하고 봄철에는 지반이 해빙된다. 도로는 다양한 재료와 단면으로 구성된 구조물이기 때문에 환경성과 재료 물성뿐만 아니라 포장체 각 층의 구조적 적정성 또는 지지력을 파악하는 것이 무엇보다 중요하다. 현재 기존 동상방지층 설계법에 따르면, 동상방지층은 포장체의 구조적 적정성과는 무관하게 온도조건에 따른 동결깊이에 따라 일률적으로 결정되고 있다. 이러한 동결깊이를 포장구조설계에 적용함으로써 포장의 과다설계 우려가 있다. 따라서 본 논문에서는 노상층, 동상방지층, 보조기층의 역학적 실험을 실시하여 동상민감성을 판단하고 실규모 현장도로 모형축소 실험을 실시하였다. 동상민감성을 판단하기 위하여 토층별 온도, 동결팽창량, 부동수분 및 동결깊이를 측정하였다.

실내동결시스템을 이용한 노상토의 동상 특성 (The Frost Heaving Characteristics of Subgrade Soils Using Laboratory Freezing System)

  • 신은철;류병현;박정준
    • 한국도로학회논문집
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • 겨울에는 시베리아기단의 영향으로 한랭 건조한 대륙성 고기압의 영향을 받아 춥고 건조하여 1월 평균기온이 $-6{\sim}-7^{\circ}C$의 영하의 온도로 낮아져 지반동결시 수분이동으로 동상현상이 발생하여 도로의 불균형 동결팽창을 초래하며, 결국 포장체를 파손시킨다. 동상발생시 토립자는 모관력에 의해 지하수를 흡수하여 아이스렌즈를 형성하며, 이 모관 흡수력은 토립자의 크기에 영향을 받는다. 도로는 다양한 재료와 단면으로 구성된 구조물이기 때문에 환경성과 재료 물성뿐만 아니라 포장체 각 층의 구조적 적정성 또는 지지력을 파악하는 것이 무엇보다 중요하다. 현재 기존 동상방지층 설계법에 따르면, 동상방지층은 포장체의 구조적 적정성과는 무관하게 온도 조건에 따른 동결깊이에 따라 일률적으로 결정되고 있다. 이러한 동결깊이를 포장구조설계에 적용함으로써 포장의 과다설계 우려가 있다. 따라서 본 논문에서는 도로 동상방지층의 효용성 검증 및 설치기준 확립을 위해 실내동결시스템을 활용하여 도로 노상토의 동상 특성에 대한 민감성을 판별, 도로건설 현장 노상토에 대한 역학적 특성과 실내 동결 시험을 수행하였으며, 외부 동결온도의 지속 조건에 대한 시료의 온도변화, 동상팽창압, 동상팽창량, 부동수분 등의 결과값을 통하여 동결 과정에 따른 지반공학적 특성을 평가하였다.

도로포장 현장계측 온도데이터를 이용한 도로포장체의 동결깊이 연구 (A Study on The Frost Penetration Depth of Pavement with Field Temperature Data)

  • 신은철;이재식;조규태
    • 한국도로학회논문집
    • /
    • 제13권1호
    • /
    • pp.21-32
    • /
    • 2011
  • 포장의 동결깊이는 30년간의 기온자료를 분석하여 만든 동결지수를 근거로 하여 동상방지층의 두께를 결정한다. 본 연구에서의 현장계측 지역은 동결지수에 따라 동결지수 550~650$^{\circ}C{\cdot}$일, 450~550$^{\circ}C{\cdot}$일, 350~450$^{\circ}C{\cdot}$일로 구분하여 지역을 선정하였고, 각 지역별로 절토부, 절성경계부, 저성토부(2m 이하 성토부) 구간으로 단면을 구분하였다. 각 단면에 동상방지층 유 무를 구분하여 포장층별로 계측기(온도, 함수비)를 설치하고 데이터를 수집하였다. 현장 모니터링 시스템을 통하여 수집된 데이터 분석을 통하여 포장된 도로의 동결깊이를 결정하는데 이용할 수 있다. 연구 결과, 동상방지층이 없을 경우 동결지수 550~650$^{\circ}C{\cdot}$일 지역에서는 대기온도에 따라 겨울철 노상층의 온도가 $0^{\circ}C$ 이하로 나타났고, 동결지수 450~550$^{\circ}C{\cdot}$일 지역에서는 지역별로 상이했으며, 동결지수 350~450$^{\circ}C{\cdot}$일 지역에서는 동상방지층이 없어도 노상층의 온도가 $0^{\circ}C$ 이하로 나타나지 않았다. 또한, 포장 단면별로 동결깊이를 비교한 결과 대기온도에 따라 동결깊이는 절토부가 가장 높았으며, 절성경계부, 저성토부 순으로 단면별 차이가 나타났다.

마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구 (An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution)

  • 장영수;윤원남
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

착상조건에서 R134a와 R1234yf를 적용한 핀-관 형태의 증발기 성능 비교 (Performance Comparison of Fin-Tube Type Evaporator using R134a and R1234yf under the Frost Condition)

  • 신윤찬;김진현;조홍현
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5795-5801
    • /
    • 2015
  • 식생활의 향상 및 다양화로 신선한 제품에 대한 요구가 증가하고 있으며, 이에 따라 냉장 및 냉동식품의 저온유통 또한 점차 증가되고 있다. 현재 냉동산업에는 주로 R134a 냉매가 사용되고 있으며 GWP(Global Warming Potential)가 1300으로써 매우 높아 지구온난화에 영향을 미친다. 이를 대체하기 위한 냉매로써 R1234yf 냉매가 있으며, GWP는 4로써 매우 낮다. 냉동탑차 냉장시스템에 사용되는 증발기는 저온조건에서 작동되기 때문에 서리가 형성되어 시스템의 성능을 급격히 감소시킨다. 따라서, 본 연구에서 R134a와 R1234yf 냉매를 작동유체로 사용한 증발기의 성능을 착상조건 하에서 다양한 운전조건으로 분석하였다. 해석결과, 서리성장 조건에서 공기측 입구온도, 상대습도, 증발온도 변화에 대하여 R134a 증발기의 성능이 R1234yf 증발기보다 더욱 민감하게 나타났으며 서리의 성장 또한 R134a 증발기가 더 크게 나타났다.

국내 LTPP 온도 자료를 이용한 동결지수와 동결깊이 검증 연구 (Verification of Freezing Index and Frost Penetration Depth with Temperature Data of Korea LTPP)

  • 김부일;전성일;이문섭;임광수
    • 한국도로학회논문집
    • /
    • 제11권4호
    • /
    • pp.143-152
    • /
    • 2009
  • 본 연구의 목적은 현재 국내에서 적용되고 있는 동결지수와 동결깊이 산정의 타당성을 검증하는 것이다. 이에 국내에서 운영되고 있는 LTPP-SPS(Long Term Pavement Performance- Specific Pavement Study)구간의 대기온도와 포장체 깊이별 온도 데이터를 이용하여 동결지수와 동결깊이를 산정하였으며, 기존 계산식을 이용하여 산출된 동결깊이와 비교 분석하였다. 또한 이 구간들의 인근 측후소 데이터를 이용하여 연도별 동결지수 추이를 분석하였다. 본 연구 결과, 지구온난화에 의해 1987년 이후에는 동결지수가 급격히 감소하였으며, 현재 도로설계 시 적용되고 있는 동결지수가 과하게 적용되고 있음을 알 수 있었다. 이에 동결지수 산정 시 현행 30년 데이터를 토대로 산정하기보다 기후가 변화된 시점부터 현재까지의 추이를 분석하는 것이 바람직 할 것으로 사료된다. 또한 LTPP-SPS 구간에서 측정된 포장체 깊이별 온도데이터를 분석한 결과, 동상방지층이 설계되어 있는 3개구간에서 대체적으로 보조기층까지만 동결이 발생하는 것으로 나타나, 동상방지층이 제 역할을 수행하지 못하는 것으로 나타났다. 실제 측정된 동결깊이와 계산식을 통해 산정된 동결깊이를 비교한 결과, 노상동결관입허용법을 이용한 설계방법이 실제 측정된 동결깊이와 가장 유사한 경향을 나타내었다.

  • PDF

토목섬유로 보강된 철도노반의 설계기법 (A Design Method of Reinforced Railway Roadbed by Geosynthetics)

  • 심재범;채영수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.423-429
    • /
    • 1999
  • The design method of Geosynthetics reinforced Railway Roadbed that was developed in Germany in 1997 is presently putting into practice. This method insists that Railway Roadbed Thickness has to be measured by Frost and Bearing Capacity The Maximum Value from the above two measurements is the necessary Railway Roadbed Thickness. This design method has many kinds of advantage in economic, constructive aspect, and environmentalism. Recently a few Korean experts actively have researched on this area, but their results are not enough for proper design method. Ⅰ hope more complete study on this area will be progressed.

  • PDF

온도조건에 의한 도로하부 지반의 동결 및 지지력 특성 (Freezing and Bearing Capacity Characteristics of Road Foundations under Temperature Condition)

  • 신은철;김성환;박정준
    • 한국지반공학회논문집
    • /
    • 제28권3호
    • /
    • pp.5-14
    • /
    • 2012
  • 현재 기존 동상방지층 설계법에 따르면, 동상방지층은 도로 노상토의 동상특성이 아닌 온도에 따른 동결깊이에 근거해 일률적으로 결정되어 포장설계의 부실 또는 과다설계 우려가 있다. 도로는 다양한 재료와 단면으로 구성된 구조물이기 때문에 환경성과 재료 물성 뿐만 아니라 포장체 각 층의 구조적 적정성 또는 지지력을 파악하는 것이 무엇보다 중요하다. 따라서 본 논문에서는 대형 냉동고내에 실내모형토조를 구성하여 포장하부구조재료(노상층, 쇄석골재층)의 시간에 따른 온도와 동상량 변화, 동결융해에 따른 지반의 지지력 변화를 통하여 포장하부구조체의 역학적 관계를 분석하였다.