• Title/Summary/Keyword: Front air velocity

Search Result 111, Processing Time 0.029 seconds

Structural Variation of Methane/Air Premixed Flame Caused by the Intervention of Ultrasonic Standing-wave (정상 초음파장의 간섭에 의한 메탄/공기 예혼합화염의 구조 변이)

  • Seo, Hang-Seok;Lee, Sang-Shin;Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.1-6
    • /
    • 2011
  • An experimental study has been conducted to scrutinize into the influence of ultrasonic standing wave field on the variation of methane/air premixed flame structure. Visualization technique utilizing the Schlieren method is employed for the observation of premixed flame propagation. The shape of flame front and local flame velocity are measured according to the variation of reactants pressure and chamber opening/closing condition. The flame fronts affected by the standing wave are clearly distorted but the vertical locations of frontal dents do not undergo any appreciable change. The influence of standing wave on the flame front becomes more prominent as the flame propagates downward. It is found that the propagation velocity of flame front with excitation of standing wave is greater than the case without the excitation. It is eventually revealed that the flame is deformed to lotus-shaped one by the vivid interaction of ultrasonic standing-wave with the reflected wave coming from the right side.

A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity (다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2323-2327
    • /
    • 2010
  • The experimental apparatus consists of dehumidifier with multi-layer type heat exchangers to remove the moisture from automatic equipments, semiconductors, and manufacturing processes under the low temperature environment, and chemical production lines which are likely to take moisture. The major components of this system are four evaporators with different fin pitch, two compressors, two condensers and an expansion valve. In this study, the performance characteristics of dehumidifier is analyzed by the variations of frontal air velocity in the first heat exchanger(evaporator). The cooling capacity of each heat exchanger is acquired by the enthalpy calculating from measuring point of temperature and relative humidity of the first heat exchanger from 1.0m/s to 4.0m/s with increasing interval 0.5m/s, and the front air velocity. As a result, it is found that cooling capacity of the first heat exchanger showed the best cooling capacity when its frontal air velocity is 2.0 m/s.

Simultaneous Measurements of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames (CH-OH PLIF와 Stereoscopic PIV동시계측에 의한 난류예혼합화염의 관찰)

  • Choi, Gyung-Min;Tanahashi, Mamoru;Miyauchi, Toshio
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.91-96
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry (PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Reynolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Reynolds number turbulent premixed flame. The Reynolds number dependence of the flame front was clearly captured by the simultaneous CH-OH PLIF and stereoscopic PIV measurements.

  • PDF

A Kinematic Comparison of Start Motion Between the Swimming and Fin-Swimming (수영과 핀수영 스타트 동작의 운동학적 비교)

  • Kim, Seung-Kwon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.97-105
    • /
    • 2008
  • The kinematic variables for swimming and fin-swimming start motions were analyzed and compared using 3-dimensional cinematography. For the swimming start, the arm segment moved towards the upper rear and trunk towards the upper front followed by a descent towards the lower front, while the fin-swimming start motion showed movement towards the lower front for all segments. The total body center of gravity for the swimming start showed horizontal movement far to the front followed by a rapid descent while the fin-swimming start showed close movement towards the lower front in a short period of time. Upon entering the water, the center of gravity for swimming showed high vertical velocities while fin swimming had high horizontal velocities. For both swimming and fin swimming, the upper extremity velocity had more influence on the total center of gravity velocity than the lower extremities. Flexion of the hip joint was observed before the jump for the fin swimming start while the swimming start showed two flexions in mid-air succeeding the jump. The flexion and extension movements at the knee joint during the fin-swimming start motion were shown to be larger and more rapid than those of fin-swimming.

A Study on the Pressure Change during the Pressurization to the Elevator Lobby (부속실 급기가압 시 압력특성 변화에 관한 연구)

  • Kim, Beom-Kyue;Park, Yong-Hwan;Kim, Hong-Sik
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2012
  • This study investigated the pressure change in the fire room and elevator lobby during the air pressurization to the Elevator lobby with the various egress scenarios and the existence of vent holes in the fire room. The experiments revealed that pressure change was significantly affected by the open/closure scenarios of the front door and stairway door resulting in over pressure, under pressure and performance drop of the door closure. It also revealed that the required smoke defensive air velocity can be obtained only with the existence of vent holes in the fire room by the removal of back pressure in the fire room.

Interacting Effects of an Ultrasonic Standing-wave on the Propagation Behavior and Structural Stabilization of Propane/Air Premixed Flame (프로판/공기 예혼합화염의 전파거동 및 구조안정화에 대한 정상초음파의 간섭효과)

  • Lee, Sang Shin;Seo, Hang Seok;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.1-8
    • /
    • 2012
  • An experimental study has been conducted to scrutinize into the influence of ultrasonic standing wave on the propagating behavior and structural stabilization of propane/air premixed flame at various equivalence ratios in half-open rectangular duct. Evolutionary features of the flame fronts are caught by high-speed images, and the variation of flame structure and local flame velocities along the propagation are analyzed. It is revealed that the propagation velocity agitated by the ultrasonic standing wave is greater than that without the agitation: the velocity enhancement diminishes as the equivalence ratio approaches the stoichiometric. Influence of standing wave on the flame overwhelms that of the buoyancy which slants the flame front towards top of the duct, and thus the standing wave contributes to the structural stabilization of propane/air premixed flame.

Numerical study on the Air Flow Characteristics inside a DPF with Diffuser Shape (확대관 형상에 따른 DPF 내의 유동특성 해석)

  • Rhim, Dong-Ryul;Lee, Sang-Up;Kim, Min-Jung;Kim, Soong-Kee;Kim, Seong-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.796-802
    • /
    • 2005
  • Numerical analysis has been conducted for improving air flow characteristics in the exhaust aftertreatment system of diesel-fueled passenger cars by changing axial length and cone shape of a DPF diffuser. The results of air velocity and static pressure distributions along with air flow uniformity results suggest that a diffuser shape with 2D or 3D function type is better for air flow patterns in front of a DPF.

  • PDF

Counter-Current Flow Limit of a Vertical Two Phase (Water/Air) Flow (상반류(물/공기) 유동한계에 관한 연구)

  • 오율권;조상진;김상녕;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.308-322
    • /
    • 1991
  • A set of experiments of Counter-Current Flow Limit(CCFL or Flooding) was performed to improve the drawbacks of Wallis' Correlation which neglects the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In these experiments using water and air, the followings were found ; (i) The effects of channel size and length were quite significant. In large tubes(D>20mm), the flooding front occurred at the bottom of the channel and when the gas flow increased the front moved upward ; however, in small tubes(D<20mm), there were no upward movement of flooding front and the flooding just occurred at the liquid inlet. (ii) The effect of water inlet device was not as significant as that of channel length though the inlet boundary conditions could affect the flow development and flooding afterward. (iii) Once the flooding front reached the inlet of water injection device, an newly reduced flow condition was set up and resulted in another flooding corresponding to the new condition.

Three-Dimensional Modeling of Void Formation During Resin Transfer Molding (RESIN TRANSFER MOLDING 공정에서의 기공 형성에 관한 3차원 모델링)

  • Bae, Jun-Ho;Kang, Moon-Koo;Lim, Seoug-Taek;Lee, Woo-Il
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.246-250
    • /
    • 2001
  • In resin transfer molding (RTM), resin is forced to flow through the fiber perform of inhomogeneous permeability. This inhomogeneity is responsible for the mismatch of resin velocity within and between the fiber tows. The capillary pressure of the fiber tows exacerbates the spatial variation of the resin velocity. The resulting microscopic perturbations of resin velocity at the flow front allow numerous air voids to form. In this study, a mathematical model was developed to predict the formation and migration of micro-voids during resin transfer molding. A transport equation was employed to account for the migration of voids between fiber tows. Incorporating the proposed model into a resin flow simulator, the volumetric content of micro-voids in the preform could be obtained during the simulation of resin impregnation.

  • PDF

Control of Impinging Jet Heat Transfer with Mesh Screens (Mesh 스크린을 이용한 충돌제트 열전달 제어에 관한 연구)

  • Cho, Joung-Won;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.267-271
    • /
    • 2000
  • The local heat transfer rate of an axisymmetric submerged air jet impinging on normal to a heated flat plate was investigated experimentally with varying solidity of mesh screen. The mean velocity and turbulent Intensity profiles of streamwise velocity component were measured using a hot-wire anemometry. The temperature distribution on the heated flat surface was measured with thermocouples. The screen installed in front of the nozzle exit(behind of 35mm) modify the jet flow structure and local heat transfer characteristics. For higher solidity screen, turbulence intensity at core lesion is high and increases the local heat transfer rate at nozzle-to-plate spacings(L/D<6). For larger nozzle-to-plate spacings(L/D>6), however, the turbulent Intensities of all screens tested in this study approach to an asymptotic curve, but the small mean velocity at the core region reduces the local heat transfer rate for high solidity screens.

  • PDF