• Title/Summary/Keyword: Friction velocity

Search Result 922, Processing Time 0.024 seconds

Slaking Characteristics of shale in the Gyoungsang Super-group, Korea (경상누층군 셰일의 내구성 특성)

  • Park, Sung-Sik;Ye, Sung-Ryol;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.315-324
    • /
    • 2016
  • Because of a fissility characteristics of shale in the Gyoungsang super-group, it breaks down to debris when daylighted by construction work and causes a slope unstability. To assess the durability property of shale, a series of slake durability tests was conducted by controlling test conditions such as shape of specimen, number of specimen, revolution speed, revolution number, drying temperature and pH of submerging liquid. For the specimen shape, cube one showed relatively lower durability index than cuboid and/or fan shape one. The test with the more number of specimens showed the less durability index because of a higher friction among specimens in the drum. The durability index is linearly decreased by increasing the total number of revolution, while the revolution velocity could not affect the index. And the durability index is also decreased by increasing the drying temperature of specimen and by decreasing the pH of submerging liquid. Because the durability index of shale is almost similar to that of crystalline rocks, the disintegration characteristics of shale could not be assessed by the slake durability test recommended by ISRM, and thus a new test method by changing the total revolution number may be required for the shale having fissility characteristics.

Studies on a Plan for Afforestation at Tong-ri Beach Resort - Analysis of Factors Causing Disasters around Beach - (통리해수욕장(桶里海水浴場) 녹지대조성(綠地帶造成)에 관(關)한 연구(研究)(I) - 사구지주변(砂丘地周邊)의 재해요인분석(災害要因分析) -)

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.2
    • /
    • pp.178-185
    • /
    • 1988
  • This study is carried out for analyzing the factors causing several disasters occurring around beach area in order to set a plan for an afforestation which will fulfill its function as facilities for prevention of disasters and for relaxation around beach resort at Tong-ri, Pokil-my$\bar{o}$n, Wando-gun. The results are as follows : 1. The main wind direction was summer was SE. 2. The first class in the rate of frequency of the hourly average wind speed and the instantaneous wind speed in summer were 2.1-3.0m/sec (29.2%) and 1.1-2.0m/sec (30.6%) respectively. 3. The particle sizes of the dune sands was a little small (82.5% in 0.125 to 0.25mm, $D_{50}=0.178mm$). 4. The mineral composition and the chemical components were as follows : The main mineral : Quartz The accessary minerals : Calcite, Feldspars(Orthoclase), Sericite. The chemical components : $SiO_2$ ; 75.6%. $Al_2O_3$ ; 8.1%, CaO ; 7.76%, Ign. loss ; 6.8%, MgO ; 0.23%, $K_2O$ ; 0.72%, $Na_2O$ ; 0.41%, $Fe_2O_3$ ; 0.32%. 5. The threshold friction velocity equation for the diameter class of the dune sands was $y=4.191x^{0.221}$. 6. The amount of floating salt was maximum at the point of 65m away from beach line, dropped abruptly at 135m and remained almost same on its way to the inland. The equation of the amount of floating salt was $y=28.181{\times}(-0.369^x)$. 7. The amount of extracted salt(33%) in seawater in summer was the same as the one of the nearest seawater of Korea.

  • PDF

Engineering Characteristics of Mudeungsan Tuff and Ipseok-dae Columnar Joints (무등산응회암과 입석대 주상절리대의 공학적 특성)

  • Noh, Jeongdu;Jang, Heewon;Lim, Chaehun;Hwang, Namhyun;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.2
    • /
    • pp.161-173
    • /
    • 2020
  • This study is to examine the engineering characteristics of colunmar joints in Mudeugsan National Park, a global geopark. For these purposes, physical and mechanical properties of Mudeungsan Tuff, evaluation for the weathering degree of columnar joints, and crack behavior monitoring in columnar joints were conducted. The physical properties of Mudeungsan tuff were 1.02% for the average porosity, 0.38% for the average absorption, 2.69 g/㎤ for the average specific gravity, and 4,948 m/s for the average elastic wave velocity. Its mechanical properties were 337 MPa for the average uniaxial compressive strength, 68 GPa for the average elastic modulus, 0.29 for the average Poisson's ratio, 41.3 MPa for the average cohesion strength, and 62.8° for the average friction angle. the average rebound Q-value of the silver Schmidt hammer for the three columnar joint blocks at the Ipseok-dae was shown as 49.3. when this value is converted into uniaxial compressive strength, it becomes 70.5 MPa, which is about 21% of the uniaxial compression strength of Mudeungsan tuff. In addition, according to the results of crack monitoring measurements for the three columnar joint blocks at the Ipseok-dae, the crack behavior is less than 1 mm, so it is believed that its behavior in Ipseak-dae columnar joints has hardly occured to date.

Experimental Study on Influence of Ground Collapse due to Ground Water Level Lowering (지하수위 저하가 지반함몰에 미치는 영향에 관한 실험적 연구)

  • Kim, Sukja;Jung, Kwansue
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.23-30
    • /
    • 2018
  • According to recent ground collapse occurrence, ground subsidence is increasing every year in downtown area, which is a social problem. The purpose of this study is to investigate the relationship between ground water level lowering and ground collapse through laboratory model experiments. After mixing 1:1 granite weathered soil with sand, sandy soil was formed as a relative density of 30%, 50%, and 80%. And then the changes of soil discharge with change of groundwater level were compared. The physical property of material of which particle distribution were well graded with maximu dry unit weight of $1.94kg/cm^3$ and internal friction angle of 37degrees. Ground water levels were measured at 10 cm, 20 cm, and 30 cm from the bottom. As a result, the experiment shows that the higher the groundwater level works the higher the discharge velocity and the magnitude of underground cavity also increases with elapsed time. Finally, the cumulative quantity of soil discharge occurred up to 30 kg at the elapsed time, 35 minutes. It was also confirmed that the range of ground collapse increased due to soil discharge with ground water level lowering.

Numerical Analysis of the Hydraulic Characteristics of a Boundary Layer Streaming over Surf-Zone Using LES and Dynamic Smagorinsky Turbulence Model (LES와 Dynamic Smagorinsky 난류모형을 이용한 쇄파역에서의 경계층 Streaming 수치해석)

  • Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.1
    • /
    • pp.69-84
    • /
    • 2020
  • Natural shoreline repeats its re-treatment and advance in response to the endlessly varying sea-conditions, and once severely eroded under stormy weather conditions, natural beaches are gradually recovered via a boundary layer streaming when swells are prevailing after storms cease. Our understanding of the boundary layer streaming over surf-zone often falls short despite its great engineering value, and here it should be noted that the most sediments available along the shore are supplied over the surf-zone. In this rationale, numerical simulation was implemented to investigate the hydraulic characteristics of boundary layer streaming over the surf zone in this study. In doing so, comprehensive numerical models made of Spatially filtered Navier-Stokes Eq., LES (Large Eddy Simulation), Dynamic Smagorinsky turbulence closure were used, and the effects of turbulence closure such as Dynamic Smagorinsky in LES and k-ε on the numerically simulated flow field were also investigated. Numerical results show that due to the intrinsic limits of k-ε turbulence model, numerically simulated flow velocity near the bottom based on k-ε model and wall function are over-predicted than the one using Dynamic Smagorinsky in LES. It is also shown that flow velocities near the bottom are faster than the one above the bottom which are relatively free from the presence of the bottom, complying the typical boundary layer streaming by Longuet-Higgins (1957), the spatial scope where boundary layer streaming are occurring is extended well into the surf zone as incoming waves are getting longer. These tendencies are plausible considering that it is the bottom friction that triggers a boundary layer streaming, and longer waves start to feel the bottom much faster than shorter waves.

HVOF Thermal Spray Coating of WC-Co for Durability Improvement of High Speed Spindle (초고속 스핀들의 내구성 향상을 위한 WC-Co 분말의 HVOF 용사 코팅)

  • Kim, K.S.;Baek, N.K.;Yoon, J.H.;Cho, T.Y.;Youn, S.J.;Oh, S.K.;Hwang, S.Y.;Chun, H.G.
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.4
    • /
    • pp.179-189
    • /
    • 2006
  • High velocity oxygen fuel(HVOF) thermal spray coating of WC-Co powder is one of the most promising candidate for the replacement of the traditional hard chrome plating and ceramics coating because of the environmental problem of the very toxic $Cr^{6+}$ known as carcinogen and the brittleness of ceramics coating. WC-Co micron and nano powder were coated by HVOF thermal spraying method for the study of durability improvement of the high speed spindle. Coatings were planned by Taguchi program for the four spray parameters of spray distance, flow rates of hydrogen, oxygen and powder feed rate. Optimal coating process was obtained by the studies of coating properties such as porosity, surface roughness, micro hardness, and micro structure. WC-Co micron and nano powder were coated on the Inconel 718 substrate by the optimal coating process obtained in this study. The wear behaviors were studied by the sliding wear tester at room temperature and at an elevated temperature of $500^{\circ}C$ for the application to high speed spindle. Sliding wear test was carried out for four most promising hard coatings of chrome coating, ceramics coatings such as $A1_2O_3,\;Cr_2O_3$ and HVOF Co-alloy T800 for the comparison of their wear behaviors. HVOF WC-Co coating was better than other coatings showing highest micro hardness of 1400 Hv and comparable friction coefficients with others. HVOF WC-Co coating is a strong candidate for the replacement of the traditional hard chrome plating for the high speed spindle.

The Prediction and Analysis of Bed Changes Characteristics in the Seomjin River Downstream (섬진강 하류의 하상변동 특성 분석 및 예측)

  • Ceon, Ir-Kweon;Kim, Min-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.115-121
    • /
    • 2009
  • It is to use effectively for stream channel and watershed management as the prediction and the analysis of bed changes characteristics in the Seomjin river downstream. The necessary data (section, bed composition material, pivot point water elevation, coefficient of roughness) with regard to analysis of the bed changes characteristics were based upon the survey data and analysis results in the Seomjin river maintenance basic plan. The prediction of bed changes was also completed with HEC-6 model. The study results were summarized as follows: The main factor of bed changes in the Seomjin river downstream can be decided by extreme extraction of bed aggregate rather than the change of hydrological data. According to the analysis of bed stability based on the relation between friction velocity and representative grain size, and the relation between dimensionless tractive force and representative grain size, the Seomjin river downstream appears to be increased overall. The bed composition material in the stream channel of the Seomjin river of 2003 year shows higher composition rate of gravel and lower composition rate of sand as compared to those of 1989 year. According to result that the prediction of bed changes, it is estimated that the bed will be risen approximately 1.5 m to the place up to 9 km from the estuary, have been repetitively risen and fallen up to 1 m to the place between $9{\sim}21\;km$ section, and fallen about 0.5m to the place between $22{\sim}25\;km$ section. As a result, the bed of the Seomjin river downstream can be decided to be risen gradually. However, since the prediction of this study is based on the assumption that there will be no forced aggregate picking, the bed changes can be much greater than expected when there is a massive aggregate picking as it had happened before.

Estimation of Head Loss Coefficients at Surcharged Square Manhole Using Numerical Model (수치모형을 이용한 과부하 사각형 맨홀에서의 손실계수 산정)

  • Kim, Jung-Soo;Lim, Ga-Hui;Rim, Chang-Soo;Yoon, Sei-Eui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.143-150
    • /
    • 2011
  • Energy loss at manholes, often exceeding friction loss of pipes under surcharged flow, is considered as one of the major causes of inundation in urban area. Therefore, it is important to analyze the head losses at manholes, especially in case of surcharged flow. The stream characteristics were analyzed and head loss coefficients were estimated by using the computational fluid dynamics(CFD) model, FLUENT 6.3, at surcharged square manhole in this study. The CFD model was carefully assessed by comparing simulated results with the experimental ones. The study results indicate that there was good agreement between simulation model and experiment. The CFD model was proved to be capable of estimating the head loss coefficients at surcharged manholes. The head loss coefficients with variation of the ratio of manhole width(B) to inflow pipe diameter(d) and variation of the drop height at surcharged square manhole with a straight-path through were calculated using FLUENT 6.3. As the ratio of B/d increases, head loss coefficient increases. The depth and head loss coefficient at manhole were gradually increased when the drop height was more than 5cm. Therefore, the CFD model(Fluent 6.3) might be used as a tool to simulate the water depth, energy losses, and velocity distribution at surcharged square manhole.

An Experimental Study on the Effect of Air Temperature and Humidity on Humidification Performance of the Humidifying Element Used for Air Conditioning (공기 온습도가 공조용 가습 소자의 가습 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.732-740
    • /
    • 2019
  • Evaporative humidification using a humidifying element is widely used for humidification of a building or a data center. The performance of a humidifying element is commonly expressed as humidification efficiency, which is used independent of air temperature, humidity and water temperature. In this study, a series of tests were conducted at two air conditions (data center and commercial building) using two different humidifying elements (cellulose/PET and Glasdek) changing the frontal air velocity and water temperature. Results showed that the measured humidification efficiency was dependent on the air condition and water temperature. In fact, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. The reason was due to the inlet water temperature, which was lower than the dew point air temperature. As the difference between the inlet water and the dew point air temperature increased, the humidification efficiency decreased. This suggest that proper thermal model should account for the inlet region, where the amount of moisture transfer may be different from the other part of the humidification element. A simple analysis on the thermal performance of the cellulose/PET humidification element showed that the Sherwood number was adequately predicted, whereas the friction factor was ovepredicted, probably due to the simplification of the channel geometry and the neglection of the water film on the element surface.

Software Package for Pipe Hydraulics Calculation for Single and Two Phase Flow (배관 유동의 주요 변수계산을 위한 소프트웨어 시스템의 개발)

  • Chang, Jaehun;Lee, Gunhee;Jung, Minyoung;Baek, Heumkyung;Lee, Changha;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.628-636
    • /
    • 2019
  • In various industrial processes, piping serves as a link between unit processes and is an essential installation for internal flow. Therefore, the optimum design of the piping system is very important in terms of safety and cost, which requires the estimation of the pressure drop, flow rate, pipe size, etc. in the piping system. In this study, we developed a software that determines pressure drop, flow rate, and pipe size when any two of these design variables are known. We categorized the flows into single phase, homogeneous two phase, and separated two phase flows, and applied suitable calculation models accordingly. We also constructed a system library for the calculation of the pipe material, relative roughness, fluid property, and friction coefficients to minimize user input. We further created a costing library according to the piping material for the calculation of the investment cost of the pipe per unit length. We implemented all these functions in an integrated environment using a graphical user interface for user convenience, and C # programming language. Finally, we verified the accuracy of the software using literature data and examples from an industrial process with obtained deviations of 1% and 8.8% for the single phase and two-phase models.