• Title/Summary/Keyword: Frequency-domain

Search Result 3,985, Processing Time 0.032 seconds

Evaluation of Soil-Structure Interaction Responses of LNG Storage Tank Subjected to Vertical Seismic Excitation Depending on Foundation Type (기초형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 수직방향 지진응답 분석)

  • Son, Il-Min;Kim, Jae-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.367-374
    • /
    • 2019
  • We investigate the effect of soil-structure interaction (SSI) on the response of LNG storage tanks to vertical seismic excitation depending on the type of foundation. An LNG storage tank with a diameter of 71 m on a clay layer with a thickness of 30 m upon bedrock, was selected as an example. The nonlinear behavior of the soil was considered in an equivalent linear method. Four types of foundation were considered, including shallow, piled raft, and pile foundations (surface and floating types). In addition, the effect of soil compaction within the group pile on the seismic response of the tank was investigated. KIESSI-3D, an analysis package in the frequency domain, was used to study the SSI and the stress in the outer tank was calculated. Based on an analysis of the numerical results, we arrived at three main conclusions: (1) for a shallow foundation, the vertical stress in the outer tank is less than the fixed base response due to the SSI effect; (2) for foundations supported by piles, the vertical stress can be greater than the fixed base stress due to the increase in the vertical impedance due to the piles and the decrease in radiation damping; and (3) soil compaction had a miniscule impact on the seismic response of the outer tank.

A Study of Electromagnetic Coupling Analysis between Dipole Antenna and Transmission Line Using PEEC Method (PEEC 방법을 이용한 다이폴 안테나와 전송선로 사이의 전자기 결합 분석에 관한 연구)

  • Oh, Jeongjoon;Kim, Kwangho;Park, Myeongkoo;Lee, Hosang;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.902-915
    • /
    • 2017
  • In recent years, mobile devices have become increasingly multi-functional and high performance, resulting in a dramatical increase in processing speed. On the other hand, the size of device is reduced, circuits inside the device are more easily exposed to electromagnetic interference radiated from antenna or adjacent circuits, degrading the system performance. To prevent this, it is necessary to design the device considering the electromagnetic characteristics with EM simulation at the design stage of product. However, the EM simulation takes a long analysis time and require high-level system resources for fast analysis. In this paper, an equivalent circuit modeling method for a round wire is proposed using a PEEC method and the electromagnetic coupling from a dipole antenna to a transmission line is analyzed in frequency domain. And compared with the result of electromagnetic simulator. As a result, PEEC method shows good agreement with those of electromagnetic simulation, in a much more short time.

A Study on the level of Recognition and Practices of 119 Emergency Medical Technician about Infection Control (119구급대원의 감염관리에 대한 인지도와 수행도 관계 연구)

  • Yun, Hyeong-Wan;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.99-113
    • /
    • 2008
  • In order to protect Rescue 119 workers exposed on the spot from potential infection, this study identified their awareness and practices of infection control so that it could help preventing them from infection and also provide basic materials necessary for pre-hospital infection control. This study applied questionnaire survey to total 215 Rescue 119 workers at fire stations in Jeonbuk province, Jeonnam province and Gwangju city from July 14 to Sept. 14, 2006 for the benefit of data collection. The questionnaire about possible associations between awareness and practices of infection control consisted of total 46 times across 6 categories such as washing hands during emergency activities ; fluid therapy and injection ; respirator maintenance; individual hygienics ; disinfectant supplies and equipments maintenance ; and control of infectious wastes. And collected data were processed using SPSS statistic program to analyze frequency and percentage, mean and standard deviation, Pearson's correlation coefficient, t-test and one-way ANOVA. As a result, this study came to the following conclusions : In terms of awareness about infection control, our respondents showed highest awareness about infectious waste control, and also showed highest level of practices in washing hands during emergency activities. Throughout all domains, awareness means were higher than practice means. In particular, infectious waste control was the domain of significant differences between awareness and practices. In terms of associations between awareness and individual characteristics, it was found that female rescue worker group and hospital/general hospital career group (before joining the Rescue 119) showed significantly higher awareness on statistic level. In regard to associations between individual characteristics and practices, it was found that female rescue worker group showed higher level of practices than male group on statistic level. This study also analyzed correlations between rescue workers' awareness and practice of infection control. As a result, it was found that the higher awareness was in correlations with the higher practices across all 6 domains including washing hands. In addition, the higher awareness of a questionnaire item was in significantly positive correlations with the higher practice of other items. However, our respondents showed high awareness about anti-infection, but low practices in reality. This indicates necessity of devising possible solutions to improve the practices as much as awareness. Especially, it was noted that major reasons for insufficient practices of infection control guideline come from unhabituated practices and lack of supports for infection-preventing supplies and protective device (mask, etc). Hence, it is necessary to provide more infection-preventing supplies for local rescue workers sufficiently, in parallel with steady habituation of infection control. Furthermore, it is required to manage and study infection control policies even at pre-hospital step in efforts for effective infection control, education and activities.

  • PDF

Design of Multiple-symbol Lookup Table for Fast Thumbnail Generation in Compressed Domain (압축영역에서 빠른 축소 영상 추출을 위한 다중부호 룩업테이블 설계)

  • Yoon, Ja-Cheon;Sull, Sanghoon
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.413-421
    • /
    • 2005
  • As the population of HDTV is growing, among many useful features of modern set top boxes (STBs) or digital video recorders (DVRs), video browsing, visual bookmark, and picture-in-picture capabilities are very frequently required. These features typically employ reduced-size versions of video frames, or thumbnail images. Most thumbnail generation approaches generate DC images directly from a compressed video stream. A discrete cosine transform (DCT) coefficient for which the frequency is zero in both dimensions in a compressed block is called a DC coefficient and is simply used to construct a DC image. If a block has been encoded with field DCT, a few AC coefficients are needed to generate the DC image in addition to a DC coefficient. However, the bit length of a codeword coded with variable length coding (VLC) cannot be determined until the previous VLC codeword has been decoded, thus it is required that all codewords should be fully decoded regardless of their necessary for DC image generation. In this paper, we propose a method especially for fast DC image generation from an I-frame using multiple-symbol lookup table (mLUT). The experimental results show that the method using the mLUT improves the performance greatly by reducing LUT count by 50$\%$.

Optimal Value Detection of Irregular RR Interval for Atrial Fibrillation Classification based on Linear Analysis (선형분석 기반의 심방세동 분류를 위한 불규칙 RR 간격의 최적값 검출)

  • Cho, Ik-Sung;Jeong, Jong-Hyeog;Cho, Young Chang;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2551-2561
    • /
    • 2014
  • Several algorithms have been developed to detect AFIB(Atrial Fibrillation) which either rely on the linear and frequency analysis. But they are more complex than time time domain algorithm and difficult to get the consistent rule of irregular RR interval rhythm. In this study, we propose algorithm for optimal value detection of irregular RR interval for AFIB classification based on linear analysis. For this purpose, we detected R wave, RR interval, from noise-free ECG signal through the preprocessing process and subtractive operation method. Also, we set scope for segment length and detected optimal value and then classified AFIB in realtime through liniar analysis such as absolute deviation and absolute difference. The performance of proposed algorithm for AFIB classification is evaluated by using MIT-BIH arrhythmia and AFIB database. The optimal value indicate ${\alpha}=0.75$, ${\beta}=1.4$, ${\gamma}=300ms$ in AFIB classification.

Background Removal and ROI Segmentation Algorithms for Chest X-ray Images (흉부 엑스레이 영상에서 배경 제거 및 관심영역 분할 기법)

  • Park, Jin Woo;Song, Byung Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.105-114
    • /
    • 2015
  • This paper proposes methods to remove background area and segment region of interest (ROI) in chest X-ray images. Conventional algorithms to improve detail or contrast of images normally utilize brightness and frequency information. If we apply such algorithms to the entire images, we cannot obtain reliable visual quality due to unnecessary information such as background area. So, we propose two effective algorithms to remove background and segment ROI from the input X-ray images. First, the background removal algorithm analyzes the histogram distribution of the input X-ray image. Next, the initial background is estimated by a proper thresholding on histogram domain, and it is removed. Finally, the body contour or background area is refined by using a popular guided filter. On the other hand, the ROI, i.e., lung segmentation algorithm first determines an initial bounding box using the lung's inherent location information. Next, the main intensity value of the lung is computed by vertical cumulative sum within the initial bounding box. Then, probable outliers are removed by using a specific labeling and the pre-determined background information. Finally, a bounding box including lung is obtained. Simulation results show that the proposed background removal and ROI segmentation algorithms outperform the previous works.

Validation on the Bodywave Magnitude Estimation of the 2017 DPRK's Nuclear Test by Source Scaling (지진원 상대비율 측정법을 이용한 2017년 북한 핵실험의 실체파 규모 검증)

  • Kim, Tae Sung
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.589-593
    • /
    • 2018
  • Democratic Peoples' Republic of Korea (DPRK) conducted the $6^{th}$ underground nuclear test at the Punggye-ri underground nuclear test site on September 27, 2017 12 hours 30 minutes of Korean local time. Comprehensive Nuclear-Test Ban Treaty Organization (CTBTO) under U.N. announced the body wave magnitude of the event was mb 6.1 while U.S. Geological Survey (USGS)'s calculation was mb 6.3. In this study, the differences of the magnitude estimates were investigated and verified. For this purpose, a source scaling between the $5^{th}$ and $6^{th}$ event, which's epicenters are 200 meters apart, was performed using seismic data sets from 30 broadband stations. The relative amplitude variations of the $6^{th}$ event compared to the $5^{th}$ event in the frequency domain was analyzed through the scaling. The increased amount of the bodywave magnitude $m_b$ for the $6^{th}$ event was calculated at 1 Hz, which was compared to those from USGS and CTBTO's calculations.

Seismic Soil-Structure Interaction Analyses of LNG Storage Tanks Depending on Foundation Type (기초 형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 지진응답 분석)

  • Son, Il-Min;Kim, Jae-Min;Lee, Changho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.3
    • /
    • pp.155-164
    • /
    • 2019
  • In this study, the soil-structure interaction(SSI) effect on the seismic response of LNG storage tanks was investigated according to the type of foundation. For this purpose, a typical of LNG storage tank with a diameter of 71m, which is constructed on a 30m thick clay layer over bedrock was selected, and nonlinearity of the soil was taken into account by the equivalent linearization method. Four different types of foundations including shallow foundation, piled raft foundation, and pile foundations(surface and floating types) were considered. In addition, the effect of soil compaction in group piles on seismic response of the tank was investigated. The KIESSI-3D, which is a SSI analysis package in the frequency domain, was used for the SSI analysis. Stresses in the outer tank, and base shear and overturning moment in the inner tank were calculated. From the comparisons, the following conclusions could be made: (1) Conventional fixed base seismic responses of outer tank and inner tank can be much larger than those of considering the SSI effect; (2) The influence of SSI on the dynamic response of the inner tank and the outer tank depends on the foundation types; and (3) Change in the seismic response of the structure by soil compaction in the piled raft foundation is about 10% and its effect is not negligible in the seismic design of the structure.

A vision-based system for long-distance remote monitoring of dynamic displacement: experimental verification on a supertall structure

  • Ni, Yi-Qing;Wang, You-Wu;Liao, Wei-Yang;Chen, Wei-Huan
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.769-781
    • /
    • 2019
  • Dynamic displacement response of civil structures is an important index for in-construction and in-service structural condition assessment. However, accurately measuring the displacement of large-scale civil structures such as high-rise buildings still remains as a challenging task. In order to cope with this problem, a vision-based system with the use of industrial digital camera and image processing has been developed for long-distance, remote, and real-time monitoring of dynamic displacement of supertall structures. Instead of acquiring image signals, the proposed system traces only the coordinates of the target points, therefore enabling real-time monitoring and display of displacement responses in a relatively high sampling rate. This study addresses the in-situ experimental verification of the developed vision-based system on the Canton Tower of 600 m high. To facilitate the verification, a GPS system is used to calibrate/verify the structural displacement responses measured by the vision-based system. Meanwhile, an accelerometer deployed in the vicinity of the target point also provides frequency-domain information for comparison. Special attention has been given on understanding the influence of the surrounding light on the monitoring results. For this purpose, the experimental tests are conducted in daytime and nighttime through placing the vision-based system outside the tower (in a brilliant environment) and inside the tower (in a dark environment), respectively. The results indicate that the displacement response time histories monitored by the vision-based system not only match well with those acquired by the GPS receiver, but also have higher fidelity and are less noise-corrupted. In addition, the low-order modal frequencies of the building identified with use of the data obtained from the vision-based system are all in good agreement with those obtained from the accelerometer, the GPS receiver and an elaborate finite element model. Especially, the vision-based system placed at the bottom of the enclosed elevator shaft offers better monitoring data compared with the system placed outside the tower. Based on a wavelet filtering technique, the displacement response time histories obtained by the vision-based system are easily decomposed into two parts: a quasi-static ingredient primarily resulting from temperature variation and a dynamic component mainly caused by fluctuating wind load.

A study on the predictability of acoustic power distribution of English speech for English academic achievement in a Science Academy (과학영재학교 재학생 영어발화 주파수 대역별 음향 에너지 분포의 영어 성취도 예측성 연구)

  • Park, Soon;Ahn, Hyunkee
    • Phonetics and Speech Sciences
    • /
    • v.14 no.3
    • /
    • pp.41-49
    • /
    • 2022
  • The average acoustic distribution of American English speakers was statistically compared with the English-speaking patterns of gifted students in a Science Academy in Korea. By analyzing speech recordings, the duration time of which is much longer than in previous studies, this research identified the degree of acoustic proximity between the two parties and the predictability of English academic achievement of gifted high school students. Long-term spectral acoustic power distribution vectors were obtained for 2,048 center frequencies in the range of 20 Hz to 20,000 Hz by applying an long-term average speech spectrum (LTASS) MATLAB code. Three more variables were statistically compared to discover additional indices that can predict future English academic achievement: the receptive vocabulary size test, the cumulative vocabulary scores of English formative assessment, and the English Speaking Proficiency Test scores. Linear regression and correlational analyses between the four variables showed that the receptive vocabulary size test and the low-frequency vocabulary formative assessments which require both lexical and domain-specific science background knowledge are relatively more significant variables than a basic suprasegmental level English fluency in the predictability of gifted students' academic achievement.