Duplex Stainless Steel의 저온 플라즈마 침질탄화시 Pulse Frequency 및 Duty Factor에 따른 표면 특성평가 (The Influence of Pulse Frequency and Duty Factor on Surface Characteristics during Low Temperature Plasma Nitrocarburizing Treatment of Duplex Stainless Steel)

  • 천창석;이인섭
    • 한국표면공학회지
    • /
    • 제47권5호
    • /
    • pp.221-226
    • /
    • 2014
  • A low temperature plasma nitrocarburizng was implemented on the duplex stainless steel to achieve the enhancement of surface hardness without degradation of its corrosion resistance. Attempts were made to investigate the influence of Pulse frequency and Duty factor of pulsed power in a high Pulse frequency regime on the surface characteristics of the hardened layer. The hardened layer (S-phase) was formed on all of the treated surfaces. Surface hardness reached up to 1300 $HV_{0.1}$ which is about 4.6 times higher than that of the untreated material (280 $HV_{0.1}$). The thickness of the hardened layer tends to increase lightly with the higher Pulse frequency and the higher Duty factor. The corrosion resistance of nitrocarburized duplex stainless steel was almost similar to that of the untreated material. Both the Pulse frequency and the Duty factor do not have a significant influence on the corrosion property of plasma treated duplex stainless steel.

탄소혼합물 접지전극의 접지임피던스의 특성 (Characteristics of Grounding Impedances of Carbon Compound Grounding Electrodes)

  • 이강수;이복희
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.54-60
    • /
    • 2011
  • This paper presents characteristics of frequency-dependent grounding impedance and transient grounding impedance for the carbon compound grounding electrode used in the installation of computerized electronic equipment and lightning protection system. The frequency-dependent grounding impedances were measured by applying sinusoidal currents in the frequency range from 100 [Hz] to 10[MHz], and the transient grounding impedances were examined by subjecting the impulse current with the front-time between 1~80[${\mu}s$]. As a result, the ground resistance of the carbon compound grounding electrode is less than that of another type grounding electrodes. The transient grounding impedance is relatively low and the conventional grounding impedance is rather lower than the ground resistance. The frequency-dependent grounding impedance of the carbon compound grounding electrode is capacitive and the grounding impedance is decreased with increasing the frequency of injected currents. Therefore in the case that the carbon compound grounding electrode is jointly used with large-scaled grounding electrodes, it is possible to reduce the high frequency grounding impedance of the integrated grounding electrode system.

$ITO/Alq_3(60nm)/Al$의 유기 발광 소자에서 바이어스 전압과 주파수에 따른 전기적 특성 (Voltage and frequency dependent electrical properties in organic light-emitting diodes of $ITO/Alq_3/Al$)

  • 정동회;오현석;허성우;이원재;송민종;이준웅;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.464-468
    • /
    • 2003
  • Complex impedances with frequency and voltage variation were analyzed in $ITO/Alq_3(60nm)/Al$ device structure. At low frequency, complex impedance is mostly expressed by resistive component, and at the high frequency by resistance and capacitive component. We have also evaluated resistance, capacitance and permittivity.

  • PDF

저전압 능동 인덕터 VCO를 이용한 주파수 합성기 (A Frequency Synthesizer using Low Voltage Active Inductor VCO)

  • 이순재;이동건;정항근
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.471-475
    • /
    • 2010
  • This paper presents a frequency synthesizer using low voltage active inductor VCO(Voltage Controlled Oscillator). The low voltage active inductor VCO with feedback resistor increases its equivalent inductance and the quality-factor(Q). Under certain conditions, the low voltage active inductor with feedback resistor generates a negative resistance at the input. In this paper, the conditions for negative resistance are obtained by small signal analysis. The designed low voltage active inductor VCO covers a frequency band between 1059MHz and 1223MHz. The measured phase noise at 1.178GHz is -81.8dBc/Hz at 1MHz offset.

MF-BIA Analyzer를 이용한 경혈의 세포 내액과 외액에 의한 저항성분 추정 방법 제시 및 반영률 평가 (The Suggestion of MF BIA Analyzer Method to Reflect the Resistance in the Extracelluar and Intracelluar Fluid at Acupoint & the Evaluation of Reflection Rate on the Tissue under Skin)

  • 김수병;이나라;김원기;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권4호
    • /
    • pp.563-572
    • /
    • 2012
  • Objectives : The aim of this study was to suggest a new method to estimate the resistance by acupoint compositions by using the multi-frequency bioelectrical impedance analysis(MF-BIA) of 5 kHz, 50 kHz and 200 kHz within 2 cm of acupoints as a local segment. Moreover, we try to confirm the relation to between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth. Methods : Ten male subjects participated in this study. We measured the resistance at left/right ST36 at skin surface and various manual acupuncture needle insertion depth(skin, 5 mm, 10 mm, 15 mm, 20 mm, 25 mm and 30 mm). Results : It was also observed that the all measured resistances were the highest at 5 kHz and the lowest at 200 kHz. There were significant differences at 5 kHz, 50 kHz and 200 kHz between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth(p<0.05). There was no significant difference in the left and right identical acupoints under the identical condition(p>0.05). Conclusions : We conclude that the measured resistance at skin surface has limitation as to reflect the information of tissue. However, the measured resistance at each frequency was changed as similar pattern by different insertion depth. Hence, we confirmed the possibility of assumption on information of tissue which was expected to locate an acupoint.

액체절연체(실리콘유) 유전정접의 온도및 주파수의존성 (The Dependence of Temperature and Frequency for the Dissipation Factor in Liquid Dielectrics)

  • 이돈희;소병문;이수원;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.85-89
    • /
    • 1993
  • Silicone oil exhibits the properies of both organic and inorganic substances and, thus, it has many superior properties such as higher thermal resistance and lower thermal oxidation level when compared to other dielectric liquids. In order to investigate the dielectric characteristics, dielectric liquids of viscosity 1 [cSt] is chosen as the specimen and experiment is performed in the temperature range of 20∼65 [$^{\circ}C$] and frequency range of 30∼1${\times}$10$\^$6/ [Hz] respectively. As a result, the observed linear decrease in dissipation factor at the frequency range below 3 [kHz] is due to the influence of frequency, whereas the increase in dissipation factor at higher frequency range is contributed by electrode's resistance. At a fixed frequency of 30 [kHz], increasing temperature results in higher peak value and wide width of the absorption curve. This is due to the increase in dipole and viscosity. As temperature increases, dipole moment is decreased from 0.98 to 0.64 [debye]. The activation energy which causes the relaxation and loss of dielectric is obtained about 15 [kcal/mole].

  • PDF

Effects of loading frequency and specimen size on the liquefaction resistance of clean sand

  • Sung-Sik Park;Dong-Eun Lee;Dong-Kiem-Lam Tran
    • Geomechanics and Engineering
    • /
    • 제37권2호
    • /
    • pp.123-133
    • /
    • 2024
  • This study investigates the effects of loading frequency (f) and specimen size on the liquefaction resistance of clean sand. A series of cyclic direct simple shear tests were conducted on Jumunjin sand with varying consolidated relative densities (40% and 80%), f values (0.05, 0.10, and 0.20 Hz), and diameter to height (D/H) ratios (3.63, 3.18, 2.82, and 2.54). The results demonstrated the significant influence of f and D/H ratio on the number of cycles to liquefaction (Ncyc-liq) and the cyclic resistance ratio (CRR15). It was observed that increasing f linearly increased Ncyc-liq. Increasing the specimen height also led to higher Ncyc-liq values irrespective of the f or relative density. Moreover, a positive correlation between CRR15 and f indicated that higher f yielded higher CRR15. This relationship was more pronounced in dense sand than in loose sand. Specimen height also significantly affected CRR15, with increasing the specimen height resulting in higher CRR15 values. Furthermore, the effect of f on CRR15 was less significant compared to the influence of specimen height. The effect of f on the normalized cyclic resistance ratio (NCRR) was relatively negligible for loose sand but more substantial for dense sand depending on the D/H ratio. Data analysis revealed that the NCRR generally decreases as the D/H ratio increases. An interpolation formula was provided to calculate the NCRR based on the D/H ratio regardless of the f and relative density.

대구지방에서의 장열성 Salmonella의 분포와 항균제내성 (Distribution and Drug Resistance of Salmonella Causing Enteric Fever in Taegu Area of Korea)

  • 박종욱;서성일;전도기
    • 대한미생물학회지
    • /
    • 제22권3호
    • /
    • pp.295-300
    • /
    • 1987
  • Salmonella strains isolated from blood in the Dong-san hospital, Taegu during the period from 1971 to 1986 were studied for species distribution, drug resistance, and R plasmids. The number of strains was 2,527 and all of them were classified into S. typhi and S. paratyphi A. Approximately 300 strains were isolated in the period from 1974 to 1976 and 1978, 268 in 1982, and 204 in 1983, but the numbers isolated in the 1980's have a tendency to decrease as compared with those of the 1970's. S. typhi occupied 85% or more of strains isolated until 1976, but the isolation frequency decreased yearly with some variation, and S. paratyphi A increased gradually from 1974. Only 4 strains of S. paratyphi A were resistant to some drugs, and the resistance was not transferred to E. coli by conjugation. S. typhi resistant to drugs were 15 in 1971 through 1973, 24 in 1974, and 13 in 1975, but afterwards only few resistant strains were isolated. These strains were resistant to two or more drugs; chloramphenicol(Cm), tetracycline(Tc), streptomycin(Sm), sulfisomidine(Su), ampicillin(Ap), and kanamycin(Km) and no strain resistant to other drugs tested was found. Strains resistant to 3 or less drugs didn't transfer the resistance to E. coli by conjugation. There were 15 strains resistant to four or more drugs, and were isolated in years from 1972 to 1976. These strains transferred the resistance to E. coli, and the resistance was considered to be mediated by R plasmids. Transfer frequency was higher at $25^{\circ}C$ than at $37^{\circ}C$ and patterns of transferred resistance were Cm, Tc, Sm, Su; Ap, Km; Cm. R plasmids having markers of Cm, Tc, Sm and Su were classified into Inc H1.

  • PDF

원자간격 현미경의 캔틸레버의 정량적 특성평가를 위한 계측 시스템 개발 (Development of Measurement System for Quantitative Measurement of Cantilever in Atomic Force Microscopy)

  • 권현규;남기호
    • 한국기계가공학회지
    • /
    • 제6권2호
    • /
    • pp.22-27
    • /
    • 2007
  • In this study, the two methods of stiffness measurement(Spring constant) of cantilever were proposed for quantitative measurement in Atomic Force Microscopy(AFM). As the 1st method for the measurement of stiffness, the probe method, which is used in the measurement of the semiconductor mechanical and electrical properties, was applied to the measurement of the cantilever. Experiments by the probe method were performed finding the resistance value of cantilever. As the results, the resistance was measured differently along with the dimension and the thickness of cantilever that determined the stiffness(spring constant) of the lever. As the 2nd method, the vibration characteristics(Dunkerley expression) is used to obtain the stiffness of the complex structure which is combined by AFM cantilever and the standard cantilever. We measured the resonant frequency from the complex structure using the micro stages and stereo microscope. As the results, we confirmed that the vibration characteristics(Dunkerley expression) is effected the micro complex structure of AFM cantilever.

  • PDF

PZT계 압전 세라믹 변압기의 감압특성 (Characteristics of Step-Down Transformer in PZT Piezoelectric Ceramics)

  • 김오수;이준형;손정호;남효덕;조상희
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.885-891
    • /
    • 2001
  • Ring/dot-type step-down piezoelectric transformer was manufactured by using Pb[(Mn$\sub$1/3/Sb$\sub$2/3)$\sub$0.05/Zr$\sub$0.475/Ti$\sub$0.475/]O$_3$ ceramics, which have excellent high-power piezoelectric properties. The characteristics of step-down piezoelectric transformer as a function of load resistance at output terminal was examined. Voltage gain was greatly dependent on drive frequency and load resistance, and showed maximum voltage gain at the resonance frequency. The output voltage was linearly increased as the input voltage increased. Voltage gain of the step-down piezoelectric transformer with respect to input voltage was very stable when the load resistance was in the range of 50-500 $\Omega$ .

  • PDF