• Title/Summary/Keyword: Frequency of resistance

Search Result 1,503, Processing Time 0.037 seconds

Sensorless Control of Induction Motors with Simultaneous Estimation of Speed and Rotor Resistance in the Very Low Speed Region (속도와 2차 저항의 동시 추정이 가능한 유도전동기의 극 저속 영역 센서리스 속도제어)

  • 정석권;이진국;유삼상
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.552-561
    • /
    • 2004
  • This paper is concerned with a new speed sensorless induction motor scheme which can be successfully applied to at any speed including even zero speed. The proposed method is robust against rotor resistance variations. In addition, simultaneous on-line estimations of speed and rotor resistance are realized based on a feedforward type torque control approach. The rotor flux with a low frequency sinusoidal waveform has been utilized to help the simultaneous estimation for both speed and rotor resistance. The control scheme has no current minor loop to determine voltage references. Since the proposed estimation does not depend on any derivative terms of currents and stator voltages, it offers a good performance at extremely low speed region for sensorless induction motor. Furthermore, the proposed control is simply using motor parameters and stator currents without determining any PI gains for current feedback and any signal injection for the rotor resistance estimation. Finally, both simulation and experimental results are given to show the effectiveness of this method.

A Study on the Determination of Backwash Condition and Fouling in Coagulation/Ultrafiltration Membrane System (응집·한외여과 공정에서 역세척 조건 결정 및 막오염 특성에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Lee, Byoung-Cheun;Yun, Jong-Sub;Kim, Seung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.17-22
    • /
    • 2006
  • This study is about backwash condition and membrane fouling at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was $0.06m^3/d$. The result of the test, Backwash cycle time and duration time had a significant effect on the efficiency of system and backwash. Backwash duration time was determined to be fixed in 30 seconds for the system with more than 95% recovery rate, It needed 30 minute backwash frequency. During the continuous operation, membrane fouling was analyzed by determining the filtration resistance ($R_i$) and cake layer resistance ($R_c$). At the initial stage, filtration resistance highly influenced the fouling behavior. But after 1.5 hours, cake layer resistance became more important than filtration resistant.

Ship Collision Risk Analysis of Bridge Piers (선박충돌로 인한 교각의 위험도 분석)

  • Lee, Seong-Lo;Bae, Yong-Gwi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.169-176
    • /
    • 2005
  • An analysis of the annual frequency of collapse(AF) is performed for each bridge pier exposed to ship collision. From this analysis, the impact lateral resistance can be determined for each pier. The bridge pier impact resistance is selected using a probability-based analysis procedure in which the predicted annual frequency of bridge collapse, AF, from the ship collision risk assessment is compared to an acceptance criterion. The analysis procedure is an iterative process in which a trial impact resistance is selected for a bridge component and a computed AF is compared to the acceptance criterion, and revisions to the analysis variables are made as necessary to achieve compliance. The distribution of the AF acceptance criterion among the exposed piers is generally based on the designer's judgment. In this study, the acceptance criterion is allocated to each pier using allocation weights based on the previous predictions.

Measurement of Impedance of the Grounding Grid using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스 측정)

  • 이복희;엄주홍;김교운
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.303-306
    • /
    • 2002
  • This paper presents a novel method for measuring the ground impedance in grounding systems. A square wave current was injected to the main grounding grid through auxiliary electrode, and the test current and ground potential rise(GPR) were measured using the band-pass filter. Ground impedance was calculated from the sinusoidal waveforms of the test current and GPR in frequency range of 20~2100Hz. Also the resistance and reactance component of ground impedance were analyzed.

  • PDF

Power Loss Characteristics according to Winding Method of High Frequency Transformer (고주파 트랜스포머의 권선기법 따른 손실특성)

  • Kim, Il-Nam;Yoon, Shin-Yong;Lee, Gong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.49-51
    • /
    • 2004
  • This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

  • PDF

A STUDY ON THE RESONANCE TYPE HIGH-FREQUENCY INVERTER USING MOSFET (MOSFET를 사용한 공진형 고주파 인버터에 관한 연구)

  • Lee, Dal-Hae;Oh, Seung-Hoon;Kim, Dong-Hee;Yoo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.405-408
    • /
    • 1990
  • This paper is study on resonance type high-frequency inverter using self turn-off devices. The power conversion circuits adopt full-bridge of voltage-fed type. IN the circuit analysis, resistance load was used to estimate of characteristic.

  • PDF

Transfer properties of nif-plasmid pEA 9 by pEA 9::Tn5-Mob (pEA 9::Tn5-Mob에 의한 nif-plasmid pEA 9의 transfer 성질)

  • 민병환;이호자
    • Korean Journal of Microbiology
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 1988
  • Using a Tn5-Mob system, pEA9 was characterized as a self-transmissible plasmid carrying a kanamycin resistance marker. The self-transfer frequencies of pEA9 varied greatly depending on pH values. The transfer frequency was about $4\times 10^{-5}$ at pH 5, that was 10 times higher than one at pH 6.5. With a helper plasmid, transfer frequencies were increased about $10^{4}$ times than the frequencies obtained without it.

  • PDF

An Analysis of the Ground Potential Rises and Dangerous Voltages Associated with the Frequency of Ground Currents (접지전류의 주파수에 따른 대지표면전위 상승 및 위험전압의 분석)

  • Choi, Jong-Hyuk;Cho, Yong-Sung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.97-103
    • /
    • 2011
  • The most important object of grounding systems is to protect human being from electric shock. Touch and step voltages are measured to evaluate the performances of grounding systems. Dangerous voltages have been largely studied by the power frequency fault currents, on the other hand, the ground current containing the high frequency components and surge currents haven't been considered. Many attempts about the grounding impedances reported in these days show that the performance of the grounding systems in high frequency range is very different with the ground resistance. It is necessary to analyze the dangerous voltages formed by the ground currents containing high frequency components. In this paper, the ground surface potential rises near the vertical and horizontal grounding electrodes are measured at the frequency of 100[Hz], 30[kHz], and 100[kHz]. Dangerous voltages are investigated with the frequency-dependent grounding impedance. As a result, the ground surface potential rise is increased as the grounding impedance increases. Touch and step voltages near the grounding electrode whose impedance increases with the frequency are sharply raised.

Candida non albicans with a High Amphotericin B Resistance Pattern Causing Candidemia among Cancer Patients

  • Kalantar, Enayatollah;Assadi, Mojan;Pormazaheri, Helen;Hatami, Shiva;Barari, Maryam Agha;Asgari, Esfandiar;Mahmoudi, Elaheh;Kabir, Kourosh;Marashi, Seyed Mahmoud Amin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10933-10935
    • /
    • 2015
  • Background: Many scientists have reported Candida species to be of great concern because of the high frequency that they colonize and infect human hosts, particularly cancer patients. Moreover, in the last decades Candida species have developed resistance to many antifungal agents. Based on this, we aimed to identify and determine the prevalence of Candida spp from blood culture bottles among cancer patients and their antifungal resistance pattern. Materials and Methods: From the blood culture bottles isolation and identification of the Candida spp were performed by conventional microbiological techniques. The in vitro antibiotic resistance pattern of the isolates was determined by CLSI guidelines. Genomic DNA was isolated and amplified. Each gene was separated by agar gel electrophoresis. Results: Identification of Candida spp was based on the presence of yeast cells in direct examination, culture and DNA extraction. Of the 68 blood samples collected during the study period (April 2013 to October 2013), five (7.35%) were positive for the presence of Candida spp, 2 (40%) of which were identified as Candida albicans and 3 (60%) were Candida non-albicans. Conclusions: High resistance to amphotricin B was observed among all the Candida non-albicans isolates. Regular investigations into antifungal resistance will help us to get an updated knowledge about their antibiotic resistance pattern which may help the physician in selecting the antibiotics for empirical therapy.

Bandwidth-Related Optimization in High-Speed Frequency Dividers using SiGe Technology

  • Nan, Chao-Zhou;Yu, Xiao-Peng;Lim, Wei-Meng;Hu, Bo-Yu;Lu, Zheng-Hao;Liu, Yang;Yeo, Kiat-Seng
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.107-116
    • /
    • 2012
  • In this paper, the trade-off related to bandwidth of high-speed common-mode logic frequency divider is analyzed in detail. A method to optimize the operating frequency, band-width as well as power consumption is proposed. This method is based on bipolar device characteristics, whereby a negative resistance model can be used to estimate the optimal normalized upper frequency and lower frequency of frequency dividers under different conditions, which is conventionally ignored in literatures. This method provides a simple but efficient procedure in designing high performance frequency dividers for different applications. To verify the proposed method, a static divide-by-2 at millimeter wave ranges is implemented in 180 nm SiGe technology. Measurement results of the divider demonstrate significant improvement in the figure of merit as compared with literatures.