• Title/Summary/Keyword: Frequency of resistance

Search Result 1,503, Processing Time 0.04 seconds

Epidemiological characteristics of Salmonella spp. isolated from different stages of commercial swine farms

  • Suh, Dong Kyun;Jung, Suk Chan
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.2
    • /
    • pp.179-183
    • /
    • 2005
  • Epidemiological characteristics of a total of 48 swine herd with diarrhea or a history of diarrhea in Gyeongsang-do between 1999 and 2000 were performed to evaluate the prevalence of Salmonella spp., their serotypes and antibiotic resistance patterns with respect to the different stages of swine production system. A total of 139 Salmonella spp. (21%) were isolated from 662 fecal samples and the overall herd prevalence of Salmonella spp. ranged from 12.5% to 88%. The average prevalence of Salmonella spp. from swine stages of suckling/nursery, grow/finisher and sow stage were 25.7%, 19.2% and 18.4%, respectively. Ten serotypes of Salmonella spp. were identified with a predominance of S. Typhimurium, S. Derby and S. Agona. Twenty-five isolates (18%) were found to be untypable. One hundred and two Salmonella isolates (73.4%) resistant to more than 1 antibiotic were characterized by 24 diverse resistance patterns, and their frequency of antibiotic resistance was highest in grow/finisher stage (83.3%). Resistance to tetracycline (TE; 67.6%), sulfamethoxazole (SU; 46.8%) and streptomycin (ST; 28%) was most common and the most common resistance patterns were TE SU (31.4%), TE (21.6%) and TE SU ST (20.6%) in order.

Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL) (PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어)

  • Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

Analysis of behavioral characteristics of liquefaction of sand through repeated triaxial compression test and numerical analysis

  • Hyeok Seo;Daehyeon Kim
    • Geomechanics and Engineering
    • /
    • v.38 no.2
    • /
    • pp.165-177
    • /
    • 2024
  • Liquefaction phenomenon refers to a phenomenon in which excess pore water pressure occurs when a dynamic load such as an earthquake is rapidly applied to a loose sandy soil ground where the ground is saturated, and the ground loses effective stress and becomes liquid. The laboratory repetition test for liquefaction evaluation can be performed through a repeated triaxial compression test and a repeated shear test. In this regard, this study attempted to evaluate the effects of the relative density of sand on the liquefaction resistance strength according to particle size distribution using repeated triaxial compression tests, and additional experimental verification using numerical analysis was conducted to overcome the limitations of experimental equipment. As a result of the experiment, it was confirmed that the liquefaction resistance strength increased as the relative density increased regardless of the classification of soil, and the liquefaction resistance strength of the SP sample close to SW was quite high. As a result of numerical analysis, it was confirmed that the liquefaction resistance strength increased as the confining pressure increased under the same relative density, and the liquefaction resistance strength did not decrease below a certain limit even though the confining pressure was significantly reduced at a relatively low relative density. This is judged to be due to a change in confining pressure according to the depth of the ground. As a result of analyzing the liquefaction resistance strength according to the frequency range, it was confirmed that there was no significant difference from the laboratory experiment results in the basic range of 0.1 to 1.0 Hz.

Capacitance Properties of Degraded Thyristor with Temperature and Voltage (가속열화된 사이리스터의 커패시턴스 특성)

  • Seo, Kil-Soo;Lee, Yang-Jae;Kim, Hyeng-Woo;Kang, In-Ho;Kim, Nam-Kyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.131-132
    • /
    • 2005
  • In this paper, the capacitance properties of degraded thyristor with temperature and voltage were presented. As degraded thyristor, 8 thyristors with each other different reverse blocking voltage used. Its impedance and resistance properties were measured from frequency 100Hz to 10MHz applied with bias voltage from 0V to 40V. As a result, at low frequency region, that is, at the frequency 100 - 10kHz, the abrupt increasement of its capacitance was confirmed. And also, at high frequency region, the capacitance peak move toward low frequency in the region of frequency 4 - 6MHz as degradation of thyristor.

  • PDF

A Characteristics on Impedance of Degraded Thyristor with Heat and Voltage Stress (열화된 사이리스터 소자의 임피던스 특성)

  • Seo, Kil-Soo;Kim, Hyung-Woo;Kim, Ki-Hyun;Kim, Nam-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1351-1352
    • /
    • 2006
  • In this paper, the impedance properties of degraded thyristor with heat and voltage were presented. As degraded thyristor, 8 thyristors with each other different reverse blocking voltage used. Its impedance and resistance properties were measured from frequency 100Hz to 10MHz applied with bias voltage from 0V to 40V. As a result, at low frequency region, that is, at the frequency 100-10kHz, the abrupt increasement of its capacitance was confirmed. And also, at high frequency region, the capacitance peak move toward low frequency in the region of frequency 4 - 6MHz as degradation of thyristor.

  • PDF

Resistance to Potato Virus Y Conferred by PVY Replicase Gene Sequence in Transgenic Burley Tobacco (감자바이러스 Y 복제 유전자로 형질전환된 버어리종 연초의 PVY에 대한 저항성 특성)

  • Young Ho Kim;Eun Kyung Park;Soon Yong Chae;Sang Seock Kim;Kyung-Hee Paek;Hye Sun Cho
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.50-56
    • /
    • 1998
  • The complementary DNA (cDNA) of potato virus Y- vein necrosis strain (PVY-VN) replicase gene (Nlb) was transformed into tobacco (Nicotiana tabacum cv. Burley 21) plants. Out of 25 putative transformants regenerated, 3 were resistant to PVY-VN, one highly resistant plant with no symptom until seed harvest time and the other two with mild chlorotic spot symptoms at late stages after infection. No symptom was observed in the highly resistant plant, while mild vein necrotic symptoms were developed on suckers of the moderately resistant plants after seed harvest time, In the first generation (T1) via self fertilization, resistance to susceptibility frequency in transgenic plants from the highly resistant transformant was about 3 : 1, while it was lowered much (about 1:2 and 1:19) in T1 of the moderately resistant transformants. In the second generation (T2) of the highly resistant plant, resistance frequencies were similar to T1, but resistance levels varied greatly and appeared to be decreased. Key words : potato virus Y, viral replicate gene, transgenic tobacco plants, resistance.

  • PDF

A Study on the Failure Analysis and Representation Test Method of High Frequency Transformer for SMPS (SMPS용 고주파 트랜스의 고장의 분석 및 재현시험법에 관한 연구)

  • Lim, Hong-Woo;Lee, Young-Joo;Han, Ji-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.766-770
    • /
    • 2011
  • In this paper, we describe the failure analysis and representation test method that applied high frequency transformer for SMPS through analysing insulation resistance, frequency characteristic, CT analysis, Q-factor atc. And we study the judgement method that a high frequency transformer affects to other beside parts in different condition or environment. According to this method, we devise a plan for the field failure prevent and propose the securing product reliability of high frequency transformer.

High Shock-Resistant Design of Piezoresistive High-g Accelerometer

  • Yongle Lu;Zhen Qu;Jie Yang;Wenxin Wang;Wenbo Wang;Yu Liu
    • Journal of Information Processing Systems
    • /
    • v.19 no.2
    • /
    • pp.173-188
    • /
    • 2023
  • To improve the shock-resistance of piezoresistive high-g accelerometer, we propose a design of piezoresistive high-g accelerometer. The accelerometer employs special-shaped proof masses system with a cross gap. Four tiny sensing beams are bonded above the cross gap. The expression of the deformation, natural frequency and damping is deduced, and the structural parameters are optimized. The accelerometer structure is simulated and verified by finite element method (FEM) simulation. The results show that the range of the accelerometer can reach 200,000 g, the natural frequency is 453.6 kHz, and the cross-axis sensitivity of X-axis and Y-axis is 0.25% and 0.11%, respectively, which can apply to the measurement of high shock. Contrastively, the cross-axis sensitivity of X-axis and Y-axis is respectively, reduced by 93.2% and 96.9%. The sensitivity of our accelerometer is 0.88 μV/g. It is of great value for the application of piezoresistive high-g accelerometer with high shock-resistance.

A Study on the Change of Physical Properties of Lining Fabric by Washing (세탁에 의한 안감의 물성변화에 관한 연구)

  • Song, Kyoung-Hun;Jung, Young-Hee;Kim, Hyun-Mi
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.175-182
    • /
    • 1998
  • This study was to investigated physical properties of lining fabric (Nylon, Acetate, Rayon and Polyester) such as shrinkage, tensile strength, moisture regain and crease resistance. The results were as follows. 1. The number of repeated washing times and the concentration of the detergent almost didn't affect on the change of tensile strength. 2. As washing increase more, the shrinkage of all sample was more increased. In the case of Rayon, it was showed that shrinkage was high by $1{\sim}3$ times washing. In the case of Nylon, it was showed minus shrinkage according to frequency of washing. 3. The moisture regain was very decreased by 1 times washing. But the moisture regain was increased with increase in frequency of washing and resulted in it was showed a similar value with controls. 4. As the frequency of washing and the concentration of detergent increase more, the crease resistance was decreased considerably because the elasticity of fiber decreased by mechanical force such as tension, bending and pressure and alkali.

  • PDF

Analysis and design of voltage doubling rectifier circuit for power supply of neutron source device towards BNCT

  • Rixin Wang;Lizhen Liang;Congguo Gong;Longyang Wang;Jun Tao
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2395-2403
    • /
    • 2024
  • With the rapid development of DC high voltage accelerator, higher requirements have been raised for the design of DC high voltage power supply, requiring more stable high voltage with lower output ripple. Therefore, it also puts forward higher requirements for the parameter design of the voltage doubling rectifier circuit, which is the core component of the DC high voltage power supply. In order to obtain output voltage with better performance, the effects of the working frequency, the stage capacitance and the load resistance on the output voltage of the voltage doubling rectifier circuit are studied in detail by simulation. It can be concluded that the higher the working frequency of the transformer, the larger the stage capacitance, the larger the load resistance and the better the output voltage performance in a certain range. Based on this, a 2.5 MV voltage doubling rectifier circuit driven by a 120 kHz frequency transformer is designed, developed and tested for the power supply of the neutron source device towards BNCT. Experimental results show that this voltage doubling rectifier circuit can satisfy the design requirements, laying a certain foundation for the engineering design of DC high voltage power supply of neutron source device.