• Title/Summary/Keyword: Frequency component

Search Result 1,824, Processing Time 0.028 seconds

Phasor Estimation Algorithm Based on the Least Square Technique during CT Saturation

  • Lee, Dong-Gyu;Kang, Sang-Hee;Nam, Soon-Ryul
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.459-465
    • /
    • 2011
  • A phasor estimation algorithm based on the least square curve fitting technique for the distorted secondary current due to current transformer (CT) saturation is proposed. The mathematical form of the secondary current during CT saturation is represented as the scaled primary current with magnetizing current. The information on the scaled primary current is estimated using the least square technique, with the measured secondary current in the saturated section. The proposed method can estimate the phasor of a fundamental frequency component during the saturated period. The performance of the algorithm is validated under various fault and CT conditions using a C400 CT model. A series of performance evaluations shows that the proposed phasor estimation algorithm can estimate the phasor of the fundamental frequency component with high accuracy, regardless of fault conditions and CT characteristics.

Two Scale Fusion Method of Infrared and Visible Images Using Saliency and Variance (현저성과 분산을 이용한 적외선과 가시영상의 2단계 스케일 융합방법)

  • Kim, Young Choon;Ahn, Sang Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.12
    • /
    • pp.1951-1959
    • /
    • 2016
  • In this paper, we propose a two-scale fusion method for infrared and visible images using saliency and variance. The images are separated into two scales respectively: a base layer of low frequency component and a detailed layer of high frequency component. Then, these are synthesized using weight. The saliencies and the variances of the images are used as the fusion weights for the two-scale images. The proposed method is tested on several image pairs, and its performance is evaluated quantitatively by using objective fusion metrics.

The Crystallization Kinetics of CaO-MgO-Al2O3-SiO2 Glass System Using Thermal Analysis (열분석을 이용한 CaO-MgO-Al$_2$O$_3$-SiO$_2$의 결정화 기구의 연구)

  • 김형순
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.1
    • /
    • pp.9-14
    • /
    • 1992
  • Some of non-isothermal analysis methods are applied to CaO-MgO-Al2O3-SiO2 glass system to find the kinetics parameters of crystallisation, activation energy, Avrami component and frequency factor. The results using the non-isothermal analysis were compared to that of microstructure experiment. Analysis of the result has enabled to some methods to be to recommend as being the most appropriate equation to use in a glass system. It was shown that in the thermal analysis using the non-isothermal method of Kissinger, Augis-Bennett, Bansal, and Marotta, the calculation of activation energy is not much different, while Avrami component and frequency factor are different from applied each methods.

  • PDF

Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators (열화된 고분자애자의 카올린 오손에따른 표면방전특성)

  • Park, Jae-Jun;Ga, Pyung-Hyun;Seo, Ui-Won;Jung, Myeong-Yeon;Song, Il-Kwen;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

Identification of Fish Species using Affine Transformation and Principal Component Analysis of Time-Frequency Images of Broadband Acoustic Echoes from Individual Live Fish (활어 개체어의 광대역 음향산란신호에 대한 시간-주파수 이미지의 어파인 변환과 주성분 분석을 이용한 어종식별)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.2
    • /
    • pp.195-206
    • /
    • 2017
  • Joint time-frequency images of the broadband echo signals of six fish species were obtained using the smoothed pseudo-Wigner-Ville distribution in controlled environments. Affine transformation and principal component analysis were used to obtain eigenimages that provided species-specific acoustic features for each of the six fish species. The echo images of an unknown fish species, acquired in real time and in a fully automated fashion, were identified by finding the smallest Euclidean or Mahalanobis distance between each combination of weight matrices of the test image of the fish species to be identified and of the eigenimage classes of each of six fish species in the training set. The experimental results showed that the Mahalanobis classifier performed better than the Euclidean classifier in identifying both single- and mixed-species groups of all species assessed.

A Case Study of the Higher Vibration on the Driving Motors of Port Crane (항만용 크레인 구동 모터 고진동 사례 연구)

  • Kim, Yeong-Chun;Park, Heui-Joo
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.416-421
    • /
    • 2001
  • It was firstly issued that frequently broken of Encoder installed at travelling motor during RTGC operation. Estimated as broken due to excessive vibration of traveling and motor manufacturer claimed it as resonance of motor base. The principal vibration of Encoder was caused by the rotating vibration component of motor and by traveling wheel. The component transmitted from the wheel didn't have great vibration by the resonance with motor and other parts. Therefore, the plans was tried to add the support point to prevent the Encoder shaft vibrated greatly and inhibit the vibration. These showed good results.

  • PDF

A study on the 5-Tone Analysis and Classification (5음의 분석과 분류)

  • Cho, B.S.;Lee, Y.D.;Kim, J.K.;Hur, W.;Pak, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.219-222
    • /
    • 2001
  • The human speech sounds are use to diagnosis in oriental medicine with ‘0-sung’theory. In general, human voice are sound waves which generated by phonation. Two major parts of phonation are vocal cords and vocal tract. The uniqueness of individual vocal sound depend on structure and usage of their vocal cords and tract. In the oriental medicine, “0-sung (5-tones)” has been used to classify constitution of human body In order to characterize the “0-sung”, their frequency characteristics are investigated, and a principal frequency component is extracted. Then, the principal component is applied to classify sounds into “0-sung.”

  • PDF

A Study on the Design of Integrated Speech Enhancement System for Hands-Free Mobile Radiotelephony in a Car

  • Park, Kyu-Sik;Oh, Sang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2E
    • /
    • pp.45-52
    • /
    • 1999
  • This paper presents the integrated speech enhancement system for hands-free mobile communication. The proposed integrated system incorporates both acoustic echo cancellation and engine noise reduction device to provide signal enhancement of desired speech signal from the echoed plus noisy environments. To implement the system, a delayless subband adaptive structure is used for acoustic echo cancellation operation. The NLMS based adaptive noise canceller then applied to the residual echo removed noisy signal to achieve the selective engine noise attenuation in dominant frequency component. Two sets of computer simulations are conducted to demonstrate the effectiveness of the system; one for the fixed acoustical environment condition, the other for the robustness of the system in which, more realistic situation, the acoustic transmission environment change. Simulation results confirm the system performance of 20-25dB ERLE in acoustic echo cancellation and 9-19 dB engine noise attenuation in dominant frequency component for both cases.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

The Behaviors of Earthquake Monitoring System for Gyungbu High Speed Railroad on the Odaesan Earthquake (오대산지진 시 경부고속철도 지진감시시스템 거동)

  • Kim, Dae-Sang;Kim, Sung-Il;Choi, Su-Hyun;You, Won-Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.537-540
    • /
    • 2008
  • This paper reviews the operation standards and manuals of earthquake monitoring system for Gyungbu high speed railroad. The domestic earthquake monitoring system detects the acceleration data at the locations of lower part of pier and deck of viaducts and bridges, not like foreign system to do the surface ground accelerations. For the purpose of evaluating the behaviors of the domestic earthquake monitoring system, measured acceleration data on the Odaesan earthquake at Iwon viaduct were analysed. The values of maximum acceleration level of the viaduct were increased from 0.0089g(EW component) of the lower part of pier to 0.014g(EW component) on the deck of the viaduct. And also the predominant periods and frequencies were analysed by the frequency domain analysis.

  • PDF