• Title/Summary/Keyword: Frequency Analyser

Search Result 38, Processing Time 0.027 seconds

Design of RF Digital Spectrum Analyser for Mobile Communication (이동 통신용 RF 디지털 스펙트럼 분석기 설계)

  • Woo, Kwang-Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.29-34
    • /
    • 2007
  • It is important to analyse the frequency spectrum for the measurement of modulated signal, distortion, and noise. The frequency spectrum analysis is performed by the execution of Radix-2 DIT DFT i.e. FFT algorithm. The discrete input signal converted by A/D converter from the input signal in time domain is mathematically transformed to the frequency spectrum by FFT algorithm. In this study, we design the digital spectrum analyser by the hardware based on the TMS320F2812 DSP and AD9244 converter, and by the software based on the C28x S/W modules. We can timely analyse the frequency spectrum in mobile communication system by the digital frequency analyser based on the high performance DSP and S/W modules. This real-time analysing capability is the important performance in the internet-based mobile communication server system.

Frequency modulation of a waveguide cavity cw IMPATT diode oscillator (도파관캐비티를 사용한 임팻다이오드 발진기의 주파수변조특성)

  • 윤현보
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.6
    • /
    • pp.1-4
    • /
    • 1975
  • This paper dells with the impedance variations of the IMPATT diode depending upon the small a.c. coomponent superimposed on the d.c. bias. The frequency deviation of the modulated wave is measured using a carrier null method on microwave spectrum analyser. Frequency modulation is achieved by the weack a.c. signal superimposed on the d.c. bias. The bandwidth rapidly increase with increasing modulation signal magnitude for constant modulation frquency and slightly decrease with decreasing modulation frequency for constant modulation signal magnitude.

  • PDF

Development of Sound Frequency Analyser using an Ultra-Low Power MCU (초저전력 Micro Controller Unit(MCU)를 활용한 소리 주파수 분석기 개발)

  • Choi, Jae-Hoon;Chung, Yong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.403-410
    • /
    • 2016
  • Materials made of metals have their own manifest resonant frequencies. Using this property, the quality test of products from the factory can be performed. An impact is applied to the product and the frequencies of the sound and/or vibration are measured using high-end equipments. They use a general purpose computer or a DSP(: Digital Signal Processor)-based stand-alone system which is usually too large in-size to carry and expensive to build. In this paper, we introduce a system that is developed based on a MSP430 MCU(:Micro-Controller Unit) from TI(: Texas Instruments). The ultra-low power MSP430 MCUs make it possible to make a frequency analyzer in a very small size without the need of using a large-size battery. The proposed system can be used in situations where the frequency analyzer should be carried easily with an investigator and should be built at low cost sacrificing some accuracy. We implemented the system using a launchpad supplied by TI and could confirm that the proposed system could identify with a high-accuracy the frequencies of various artificial and natural sounds.

Acoustic Analysis of Reinke Edema (라인케부종환자의 음성분석)

  • 김상균;최홍식;공석철;홍원표
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.7 no.1
    • /
    • pp.11-19
    • /
    • 1996
  • Reinke's edema is used for describing varying degrees of chronic swelling of the vocal folds. The acoustic analysis of Reinke's edema has not been reported so far in this country. The purpose of this study is to clarify acoustic and aerodynamic characteristics of the Reinke's edema. Several acoustic evaluations & aerodynamic studies were done in 20 Reinke's edema patients and the data was compared with those of 20 normal controls. Videolaryngoscopy also was done to classify the severity in grading. We used C-Speech, Doctor speech science, and Phonatory function analyser. In C-Speech, we compared jitter, shimmer, and SNR(signal to noise ratio) of normal and Rrinke's edema patient. In Doctor speech science, we compared NNE(Glottal noise energy), speech fundamental frequency, voice quality between two groups. And in phonatory function analyser for aerodynamic function test, we compared speech intensity, airflow rate, and expiratory pressure between two groups. In conclusion, Reinke's edema patients showed lower voice pitches than normal, additionally jitter, shimmer, SNR(signal to noise ratio), NNE(Glottal noise energy), airflow rate, and expiratory pressure may be meaningful parameters for diagnosis and prognosis for treatment.

  • PDF

The Surface Analysis of the Merocyanine Dye LB film using Optical system (광학시스템을 이용한 메로시아닌 색소 LB막의 표면 모폴로지 해석)

  • Kang, Ki-Ho;Shin, Hoon-Kyu;Chang, Jung-Soo;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1714-1716
    • /
    • 2000
  • We fabricated the optical system of merocyanine dye using Langmuir-Blodgett(LB) technique because quite uniform orientation could be obtained, which is one of the most important factors to affect to its optical characteristics. The resonance frequency and other electrical parameters at the parallel resonance state were measured using the impedance analyser(HP 4294 A). Also the morphological changes of dye molecules after UV irradiation were observed using AFM. The parallel resonance frequency and resistance by electrical equivalent circuit were decreased with the UV irradiation and these aspects are different from general mass adsorption process. Therefore the structural changes of dye molecules are being considered, that is, the aggregated molecules become dissociated. It indicates that the shifts of the resonance frequency and the others occurred without mass absorption.

  • PDF

Simplified method on measurement and evaluation of floor impact sound using impact ball (임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법)

  • Kim, Yong-Hee;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

A Study on TMJ Sound by Sonopak (SONOPAK를 이용한 약관절음에 관한 연구)

  • Sung-Chang Chung;Soo-Young Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 1992
  • The purpose of this study was to investigate the characteristics of TMJ sounds by computerized sound power-spectrum analyser(SONOPAK, Bioresearch Inc., U.S.A.). TMJ sounds were recorded and anaylsed in the 87 patients wit TMJ noises by SONOPAK. The followings are the criteria of TMJ sound analysis. 1. It is possible to record the location of the TMJ sound in relation to the opening/closing cycle of mouth. 2. It is possible to record amplitude of sound(loudness) and frequency of sound (Hz) 3. Clicks display a narrow band of sound within the 0-300 Hz range. The peak frequency generally occurs between 50-150 Hz. And crepitus appear as a wide band of sound, occuring from 0-1300Hz. The data obtained from quantitative TMJ sound analysis give lots of information, but further researches are needed.

  • PDF

Calibration of frequency propagation channel sounder based on five-port reflectometer

  • Yem Van;Braga Judson;Huyart B;Begaud X;de Sousa F.R;Huyen Nguyen Bich
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.23-26
    • /
    • 2004
  • Five-port reflectometer which consists of a ring with 5 arms (two inputs, three outputs) and three RF power detectors has been used as a vector network analyser, a demodulator in the homodyne receiver as well as in Phase Looked Loop (PLL) and so on. Calibration of five-port reflectometer is an important task. In this paper, we present a calibration method of five-port for a propagation channel sounder. The method is based on measurement of the phase differences between the three voltages at the five-port's outputs in order to determine the ratio of two input incident waves. The frequency channel sounder based on five-port is calibrated for each frequency from 2.2 GHz to 2.6 GHz with 1 MHz step. This method can also determine the absolute delays of each propagation path in the propagation channel. The calibration method is validated using measurement data.

  • PDF

Frequency response characteristics of PZT pressure sensor using three dimensional LTCC substrates (3차원 LTCC 기판을 이용한 PZT 압력센서의 주파수 응답 특성)

  • Hur, Won-Young;Lee, Kyung-Chun;Hwang, Hyun-Suk;Lee, Tae-Yong;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.204-204
    • /
    • 2010
  • A development of device with reduced size and improved sensitivity is highly impotant Pb(Zr,Ti)$O_3$ thin films are widely used both to make actuator and sensor due to their high sensitivity and low cost. In this study, the feasibility of a piezoelectric presssure sensors based on hybrid low-temperaute co-fired ceramic (LTCC) technology were presented. The LTCC diaphragms with thickness of $400\;{\mu}m$ were fabricated by laminating 4 green tapes which consist of alumina and glass particle in an organic binder. PZT thin films were successfully prepared on between top and bottom Au electrode with LTCC substrates using RF magnetron sputtering. In addition, The frequency response characteristics of the sensor under varing pressure has been analysed. by Network Analyser (HP-8722D). A frequency shift range has been obseved from 1.7GHz to 1.8GHz with a good linearity for applied pressure from 0 psi up to 25 psi.

  • PDF

Fault Monitoring System for Cables Using a Compact Impedance Analyzer (소형 임피던스 분석기를 이용한 케이블의 결함 감시 시스템)

  • Yoon, Chai-Won;Yong, Hwan-Gu;Kim, Kwangho;Nah, Wansoo;Chae, Jang-Bum;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.872-879
    • /
    • 2017
  • This work presents a cable fault monitoring system based on the differential frequency domain reflectometry using a compact impedance analyser which is composed of a direct digital synthesizer, an op amp and a gain/phase detector with a micro controller. The proposed system can replace expensive vector network analysers for frequency domain reflectometry and therefore be deployed in sensor networks for long term multi-point cable monitoring. Effectiveness of the system is experimentally confirmed by diagnosing the status of the power cable.