• Title/Summary/Keyword: Freezing-lipid filtration

Search Result 2, Processing Time 0.018 seconds

Rapid Determination of Chlorostyrenes in Fish by Freezing-Lipid Filtration, Solid-Phase Extraction and Gas Chromatography-Mass Spectrometry

  • Kim, Min-Sun;Park, Kwang-Sik;Pyo, Hee-Soo;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.352-356
    • /
    • 2008
  • An analytical method has been developed for measuring chlorostyrenes in fish tissue sample. Extraction of chlorostyrenes from fish tissue was carried out by ultrasonication using acetone/n-hexane (5:2, v/v) mixture. Most of the lipids in the extract were eliminated by freezing-lipid filtration, prior to solid-phase extraction (SPE) cleanup. During freezing-lipid filtration, about 90% of the lipids extracted from the fish samples were easily removed without any significant losses of chlorostyrenes. For purification, SPE using Florisil was used for the rapid and effective cleanup. Quantification was performed using gas chromatography-mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery was above 80% in the spiked fish tissue sample at 10 and 100 ng/g levels, respectively. The detection limits for chlorostyrenes were ranged from 0.05 to 0.1 ng/g. This developed method is demonstrated to give efficient recoveries and LODs for detecting chlorostyrenes spiked into fish tissue with high lipid content.

Determination of Trichlorfon Pesticide Residues in Milk via Gas Chromatography with μ-Electron Capture Detection and GC-MS

  • Hem, Lina;Khay, Sathya;Choi, Jeong-Heui;Morgan, E.D.;El-Aty, A.M. Abd;Shim, Jae-Han
    • Toxicological Research
    • /
    • v.26 no.2
    • /
    • pp.149-155
    • /
    • 2010
  • The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with ${\mu}$-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dichloromethane was dissolved in ethyl acetate for gas chromatography. Recovery concentration was determined at 0.5, 1.0, and 2.0 of times the maximum permitted residue limits (MRLs) for trichlorfon in milk. The average recoveries (n = 6) ranged from 92.4 to 103.6%. The repeatability of the measurements was expressed as relative standard deviations (RSDs) ranging from 3.6%, to 6.7%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.7 and $11.1{\mu}g/l$, respectively. The accuracy and precision (expressed as RSD) were estimated at concentrations from 25 to $250{\mu}g/l$. The intra- and inter-day accuracy (n = 6) ranged from 89.2% to 91% and 91.3% to 96.3%, respectively. The intra- and inter-day precisions were lower than 8%. The developed method was applied to determine trichlorfon in real samples collected from the seven major cities in the Republic of Korea. No residual trichlorfon was detected in any samples.