• Title/Summary/Keyword: Freezing weather season

Search Result 16, Processing Time 0.029 seconds

A Study on Factors that Influence Traffic Accident Severity in Road Surface Freezing (결빙구간의 교통사고 심각도 영향 요인 연구)

  • Lee, Sang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.150-156
    • /
    • 2017
  • A frozen road surface increases traffic accidents during the winter season. Hence, information on easily-frozen road sections and their specificities are required to prevent traffic accidents. Frozen road surfaces are determined by equipment measuring road surface temperatures. However, there are limitations in investigating the entire road network. Therefore, it is imperative to develop new methods that effectively determine road surface freezing risks. Meteorologically, road surfaces are frozen when the actual temperature cools down to the dew point temperature. Under this condition, there is likely to be frost if relative humidity reaches 100% and frozen road surfaces as the temperature gets lower. Meteorological characteristics give us an alternative to a direct measurement road surface temperature to estimate risks of road surface freezing. Based on the clues, the relationship between severity of traffic accidents and temperature changes is empirically investigated using Paju weather data. The results reveal that as the temperature gets lower and changes in current temperature are relatively small, the severity of traffic accidents become higher. In addition, the same is true when the difference between current temperature and the dew point temperature is relatively small, as it increases possibilities of road surface freezing. Future studies must investigate how current temperature and the dew point temperature affect road surface freezing and thereby establish a time-space scope to estimate possible road surface freezing sections using only weather and road material type data. This would provide invaluable information for predicting and preventing frozen road accidents based on weather patterns.

The Frost Heaving Characteristics of Subgrade Soils Using Laboratory Freezing System (실내동결시스템을 이용한 노상토의 동상 특성)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Park, Jeong-Jun
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.71-79
    • /
    • 2010
  • The influence of fines of the frost susceptibility of subgrade soils were established by laboratory freezing system test simulating closely the thermal conditions in the field. During the winter season, the climate is heavily influenced by the cold and dry continental high pressure. Because of siberian air mass, the temperature of January is $-6{\sim}-7^{\circ}C$ on average. This chilly weather generate the frost heaving by freezing the moisture of soil and damage potential of the road structure. In the freezing soil, the ice lenses increase the freeze portion of soil by absorbing the ground water with capillary action. However, the capillary characteristics differ from the sort of soil on the state of freezing condition. In the current design codes for anti-freezing layer, the thickness of anti freezing layer is calculated by freezing depth against the temperature condition. Therefore, they have a tendency of over-design and uniform thickness without the considerations of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential for studying the appropriateness and bearing capacity besides the seasonal and mechanical properties of pavement materials to take a appropriate and reasonable design of the road structure. In this Paper, the evaluation of frost susceptibility was conducted by means of the mechanical property test and laboratory freezing system apparatus. The temperature, heaving amount, heaving pressure and unfrozen water contents of soil samples, the subgrade soils of highway construction site, were measured to determine the frost susceptibility.

A Study of the Indoor Thermal Environment in Apartment Buildings in Freezing Weather Operation of Heat Recovery Ventilator by CFD Simulation (CFD를 이용한 열회수형 환기장치 운전에 따른 혹한기 공동주택의 실내 열환경 검토)

  • Kim, Chang-Yeon;Park, Jong-Il;Kim, Dong-Gyu;Shin, Byong-Hwan;Kum, Jong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.293-299
    • /
    • 2015
  • In Korea, it is the law that an apartment building which consists of over 100 households must have a ventilation system installed, either natural or mechanical. The heat recovery ventilator (HRV) is great way to reduce energy consumption. In this research we confirmed that based on site's construction plan and existing diffuser form, performed purpose CFD which simulates operation in temperatures below $-5^{\circ}C$ to circumstances of installation of an HRV in an apartment. As a result of this research we found that when the diffuser's aperture area was adjusted, the distribution of air temperature and residence time of air was more equally distributed and air temperature was higher, compared to when the diffuser has an identical aperture area. We also found that we are able to increase even more air temperature and air distribution of air temperature and residence time of air was even more equally distributed when run in parallel with a splitter damper.

The Frost Heaving Susceptibility Evaluation of Subgrade Soils Using Laboratory Freezing System (실내 동상시스템을 이용한 노상토의 동상민감성 평가)

  • Shin, Eun Chul;Ryu, Byung Hyun;Park, Jeong Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.2
    • /
    • pp.13-23
    • /
    • 2013
  • The Korean Peninsula is considered as a seasonal frozen area that is thawed in the spring and frozen in the winter. The influence of fines of the frost susceptibility of subgrade soils were established by laboratory freezing tests simulating closely the thermal conditions in the field. During the winter season, the climate is heavily influenced by the cold and dry continental high pressure. Because of siberian air mass, the temperature of January is $-6{\sim}-7^{\circ}C$ on average. This chilly weather generate the frost heaving by freezing the moisture of soil and damage potential of the geotechnical structure. In the freezing soil, the ice lenses increase the freeze portion of soil by absorbing the ground water with capillary action. However, the capillary characteristics differ from the sort of soil on the state of freezing condition. In this study, ten soil samples are prepared. The basic physical property tests were performed by following the Korean Industrial Standard and the soil specimens were classified by the Unified Soil Classification System (USCS). These classified soils are used to perform the laboratory opened systems freezing test in order to determine the frost heaving characteristics of soils such as unfrozen water content, heaving amount, and freezing depth.

A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant (화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature around the power plant area below $5^{\circ}C$ to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplying system is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measure of temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy can be saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy saving rate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient air and three initial flowing water temperature inside the tube were used. The result shows that the temperature control system using sensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energy saving rate is almost 75% in two days basis and even 83% in one day basis.

D-PSA-K: A Model for Estimating the Accumulated Potential Damage on Kiwifruit Canes Caused by Bacterial Canker during the Growing and Overwintering Seasons

  • Do, Ki Seok;Chung, Bong Nam;Joa, Jae Ho
    • The Plant Pathology Journal
    • /
    • v.32 no.6
    • /
    • pp.537-544
    • /
    • 2016
  • We developed a model, termed D-PSA-K, to estimate the accumulated potential damage on kiwifruit canes caused by bacterial canker during the growing and overwintering seasons. The model consisted of three parts including estimation of the amount of necrotic lesion in a non-frozen environment, the rate of necrosis increase in a freezing environment during the overwintering season, and the amount of necrotic lesion on kiwifruit canes caused by bacterial canker during the overwintering and growing seasons. We evaluated the model's accuracy by comparing the observed maximum disease incidence on kiwifruit canes against the damage estimated using weather and disease data collected at Wando during 1994-1997 and at Seogwipo during 2014-2015. For the Hayward cultivar, D-PSA-K estimated the accumulated damage as approximately nine times the observed maximum disease incidence. For the Hort16A cultivar, the accumulated damage estimated by D-PSA-K was high when the observed disease incidence was high. D-PSA-K could assist kiwifruit growers in selecting optimal sites for kiwifruit cultivation and establishing improved production plans by predicting the loss in kiwifruit production due to bacterial canker, using past weather or future climate change data.

A study on the saving of energy consumption load using electrical heat control system (전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구)

  • Han, Kyu Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.1
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

Analysis of Soil Moisture Recession Characteristics in Conifer Forest (침엽수 산림에서의 토양수분 감쇄특성 분석)

  • Hong, Eun-Mi;Choi, Jin-Yong;Nam, Won-Ho;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.4
    • /
    • pp.1-9
    • /
    • 2011
  • Forest area covers 64 % of the national land of Korea and the forest plays a pivotal role in the hydrological process such as flood, drought, runoff, infiltration, evapotranspiration, etc. In this study, soil moisture monitoring for conifer forest in experimental forest of Seoul National University has been conducted using FDR (Frequency Domain Reflection) for 6 different soil layers, 10, 20, 30, 60, 90 and 120 cm during 2009~2010, and precipitation data was collected from nearby AWS (Automatic Weather Station). Soil moisture monitoring data were used to estimate soil moisture recession constant (SMRC) for analyzing soil moisture recession characteristics. From the results, empirical soil moisture recession equations were estimated and validated to determine the feasibility of the result, and soil moisture contents of measured and calculated showed a similar tendency from April to November. Thus, the results can be applied for soil moisture estimation and provided the basic knowledge in forest soil moisture consumption. Nevertheless, this approach demonstrated applicability limitations during winter and early spring season due to freezing and melting of snow and ice causing peculiar change of soil moisture contents.

The Observed Change in Interannual Variations of January Minimum Temperature between 1951-1980 and 1971-2000 in South Korea (지난 반세기 동안 남한에서 관측된 1월 최저기온의 연차변이)

  • Jung J. E.;Chung U.;Yun J. I.;Choi D. K.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.4
    • /
    • pp.235-241
    • /
    • 2004
  • There is a growing concern about the possible increase in inter-annual variation of minimum temperature during the winter season in Korea. This view is strengthened by frequently reported freezing injury to dormant fruit trees, while warmer winters have prevailed recently. The January minimum temperature record at fourteen weather stations was analyzed for 1951-2000. The results showed no evidence of increasing standard deviation at 3 locations between 1951-1980 and 1971-2000, while the remaining 11 stations showed a trend of decreasing standard deviation for the two periods. An empirical model explaining the spatial variation of the standard deviation was derived by regression analysis of 56 stations' data for 1971-2000. Daily minimum temperature and the site elevation may account for 68% of the observed variations. We applied this model to restore the average standard deviation of the January minimum temperature for 1971-2000, and the result was used to produce gridded minimum temperature data for the recurrence interval of 10 and 30 years at 250m resolution. A digital form of the plant hardiness zone map may be developed from this product for site-specific selection of adapted plant species.

Effect of Freeze Injury by Weather on Quality of 'Fuyu' Sweet Persimmon at Harvest and Subsequent Storage (수확기 동상해 피해가 '부유' 단감의 저장 품질에 미치는 영향)

  • Jo, Yun Hee;Choi, Seong-Tae;Kim, Seong-Cheol;Kim, Eun-Gyeong;Hwang, Yeon-Hyeon;Kim, Eun-Seok;Ahn, Gwang-Hwan
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • Persimmons on the trees are often exposed to weather condition of cold temperature before harvest, which affects the fruit quality at harvest time and later storage. This study investigated the effect of the harvest season temperature on the storage quality of 'Fuyu' sweet persimmons. Monitoring the temperature changes in the orchard showed five times of cold temperature below the freezing temperature of persimmon, $-2.1^{\circ}C$, in the harvesting period between mid October and mid November with the lowest being as low as $-5.4^{\circ}C$. Among three different harvestings, the tertiary one at mid November showed decreased 'L' value and consistently high 'a' value of color index and high reduction in hardness during 150 days storage of fruits at $0^{\circ}C$ showing freeze-injured symptoms, compared to the first one at mid October and the second one at early November. The fruits of first harvest maintained consistently hard texture with increased 'a' color value probably due to postharvest ripening. The tertiary harvest exhibited increase in fructose and glucose contents and decrease in sucrose of the fruits, being very different from the first and secondary harvests which maintained constant level of all three free sugars. Mid November with possible sudden temperature drop is unsuitable period for harvesting sweet persimmons in the quality at harvest and later storage, and thus the harvest should be designed to be done before that time.

  • PDF