• 제목/요약/키워드: Freezing weather season

검색결과 16건 처리시간 0.023초

결빙구간의 교통사고 심각도 영향 요인 연구 (A Study on Factors that Influence Traffic Accident Severity in Road Surface Freezing)

  • 이상준
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.150-156
    • /
    • 2017
  • A frozen road surface increases traffic accidents during the winter season. Hence, information on easily-frozen road sections and their specificities are required to prevent traffic accidents. Frozen road surfaces are determined by equipment measuring road surface temperatures. However, there are limitations in investigating the entire road network. Therefore, it is imperative to develop new methods that effectively determine road surface freezing risks. Meteorologically, road surfaces are frozen when the actual temperature cools down to the dew point temperature. Under this condition, there is likely to be frost if relative humidity reaches 100% and frozen road surfaces as the temperature gets lower. Meteorological characteristics give us an alternative to a direct measurement road surface temperature to estimate risks of road surface freezing. Based on the clues, the relationship between severity of traffic accidents and temperature changes is empirically investigated using Paju weather data. The results reveal that as the temperature gets lower and changes in current temperature are relatively small, the severity of traffic accidents become higher. In addition, the same is true when the difference between current temperature and the dew point temperature is relatively small, as it increases possibilities of road surface freezing. Future studies must investigate how current temperature and the dew point temperature affect road surface freezing and thereby establish a time-space scope to estimate possible road surface freezing sections using only weather and road material type data. This would provide invaluable information for predicting and preventing frozen road accidents based on weather patterns.

실내동결시스템을 이용한 노상토의 동상 특성 (The Frost Heaving Characteristics of Subgrade Soils Using Laboratory Freezing System)

  • 신은철;류병현;박정준
    • 한국도로학회논문집
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • 겨울에는 시베리아기단의 영향으로 한랭 건조한 대륙성 고기압의 영향을 받아 춥고 건조하여 1월 평균기온이 $-6{\sim}-7^{\circ}C$의 영하의 온도로 낮아져 지반동결시 수분이동으로 동상현상이 발생하여 도로의 불균형 동결팽창을 초래하며, 결국 포장체를 파손시킨다. 동상발생시 토립자는 모관력에 의해 지하수를 흡수하여 아이스렌즈를 형성하며, 이 모관 흡수력은 토립자의 크기에 영향을 받는다. 도로는 다양한 재료와 단면으로 구성된 구조물이기 때문에 환경성과 재료 물성뿐만 아니라 포장체 각 층의 구조적 적정성 또는 지지력을 파악하는 것이 무엇보다 중요하다. 현재 기존 동상방지층 설계법에 따르면, 동상방지층은 포장체의 구조적 적정성과는 무관하게 온도 조건에 따른 동결깊이에 따라 일률적으로 결정되고 있다. 이러한 동결깊이를 포장구조설계에 적용함으로써 포장의 과다설계 우려가 있다. 따라서 본 논문에서는 도로 동상방지층의 효용성 검증 및 설치기준 확립을 위해 실내동결시스템을 활용하여 도로 노상토의 동상 특성에 대한 민감성을 판별, 도로건설 현장 노상토에 대한 역학적 특성과 실내 동결 시험을 수행하였으며, 외부 동결온도의 지속 조건에 대한 시료의 온도변화, 동상팽창압, 동상팽창량, 부동수분 등의 결과값을 통하여 동결 과정에 따른 지반공학적 특성을 평가하였다.

CFD를 이용한 열회수형 환기장치 운전에 따른 혹한기 공동주택의 실내 열환경 검토 (A Study of the Indoor Thermal Environment in Apartment Buildings in Freezing Weather Operation of Heat Recovery Ventilator by CFD Simulation)

  • 김창연;박종일;김동규;신병환;금종수
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.293-299
    • /
    • 2015
  • In Korea, it is the law that an apartment building which consists of over 100 households must have a ventilation system installed, either natural or mechanical. The heat recovery ventilator (HRV) is great way to reduce energy consumption. In this research we confirmed that based on site's construction plan and existing diffuser form, performed purpose CFD which simulates operation in temperatures below $-5^{\circ}C$ to circumstances of installation of an HRV in an apartment. As a result of this research we found that when the diffuser's aperture area was adjusted, the distribution of air temperature and residence time of air was more equally distributed and air temperature was higher, compared to when the diffuser has an identical aperture area. We also found that we are able to increase even more air temperature and air distribution of air temperature and residence time of air was even more equally distributed when run in parallel with a splitter damper.

실내 동상시스템을 이용한 노상토의 동상민감성 평가 (The Frost Heaving Susceptibility Evaluation of Subgrade Soils Using Laboratory Freezing System)

  • 신은철;류병현;박정준
    • 한국지반신소재학회논문집
    • /
    • 제12권2호
    • /
    • pp.13-23
    • /
    • 2013
  • 겨울에는 시베리아기단에 의해 한랭 건조한 대륙성 고기압의 영향을 받는 계절동토지역인 우리나라는 춥고 건조하여 1월 평균기온이 $-6{\sim}-7^{\circ}C$의 영하의 온도로 낮아져 지반동결시 수분이동으로 동상현상이 발생하여 지반구조물의 불균형 동결팽창을 초래한다. 동상 발생시 토립자는 모관력에 의해 지하수를 흡수하여 아이스렌즈를 형성하며, 이 모관 흡수력은 토립자의 크기에 영향을 받는다. 본 연구에서는 흙의 종류에 따른 동상민감성의 차이를 알아보기 위하여 공학적 특성이 다른 10종류의 흙시료에 대하여 물리적 특성 파악과 통일분류법에 의한 흙 분류를 통해 실내동상실험을 실시하였다. 이에 각각 흙의 종류에 따른 동결깊이, 동상팽창량, 부동수분, 아이스렌즈와 같은 동상특성을 확인하여 시료의 동상민감성을 평가하였다.

화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션 (A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant)

  • 한규일
    • 수산해양기술연구
    • /
    • 제50권1호
    • /
    • pp.67-74
    • /
    • 2014
  • Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature around the power plant area below $5^{\circ}C$ to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplying system is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measure of temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy can be saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy saving rate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient air and three initial flowing water temperature inside the tube were used. The result shows that the temperature control system using sensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energy saving rate is almost 75% in two days basis and even 83% in one day basis.

D-PSA-K: A Model for Estimating the Accumulated Potential Damage on Kiwifruit Canes Caused by Bacterial Canker during the Growing and Overwintering Seasons

  • Do, Ki Seok;Chung, Bong Nam;Joa, Jae Ho
    • The Plant Pathology Journal
    • /
    • 제32권6호
    • /
    • pp.537-544
    • /
    • 2016
  • We developed a model, termed D-PSA-K, to estimate the accumulated potential damage on kiwifruit canes caused by bacterial canker during the growing and overwintering seasons. The model consisted of three parts including estimation of the amount of necrotic lesion in a non-frozen environment, the rate of necrosis increase in a freezing environment during the overwintering season, and the amount of necrotic lesion on kiwifruit canes caused by bacterial canker during the overwintering and growing seasons. We evaluated the model's accuracy by comparing the observed maximum disease incidence on kiwifruit canes against the damage estimated using weather and disease data collected at Wando during 1994-1997 and at Seogwipo during 2014-2015. For the Hayward cultivar, D-PSA-K estimated the accumulated damage as approximately nine times the observed maximum disease incidence. For the Hort16A cultivar, the accumulated damage estimated by D-PSA-K was high when the observed disease incidence was high. D-PSA-K could assist kiwifruit growers in selecting optimal sites for kiwifruit cultivation and establishing improved production plans by predicting the loss in kiwifruit production due to bacterial canker, using past weather or future climate change data.

전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구 (A study on the saving of energy consumption load using electrical heat control system)

  • 한규일
    • 수산해양기술연구
    • /
    • 제49권1호
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

침엽수 산림에서의 토양수분 감쇄특성 분석 (Analysis of Soil Moisture Recession Characteristics in Conifer Forest)

  • 홍은미;최진용;남원호;유승환
    • 한국농공학회논문집
    • /
    • 제53권4호
    • /
    • pp.1-9
    • /
    • 2011
  • Forest area covers 64 % of the national land of Korea and the forest plays a pivotal role in the hydrological process such as flood, drought, runoff, infiltration, evapotranspiration, etc. In this study, soil moisture monitoring for conifer forest in experimental forest of Seoul National University has been conducted using FDR (Frequency Domain Reflection) for 6 different soil layers, 10, 20, 30, 60, 90 and 120 cm during 2009~2010, and precipitation data was collected from nearby AWS (Automatic Weather Station). Soil moisture monitoring data were used to estimate soil moisture recession constant (SMRC) for analyzing soil moisture recession characteristics. From the results, empirical soil moisture recession equations were estimated and validated to determine the feasibility of the result, and soil moisture contents of measured and calculated showed a similar tendency from April to November. Thus, the results can be applied for soil moisture estimation and provided the basic knowledge in forest soil moisture consumption. Nevertheless, this approach demonstrated applicability limitations during winter and early spring season due to freezing and melting of snow and ice causing peculiar change of soil moisture contents.

지난 반세기 동안 남한에서 관측된 1월 최저기온의 연차변이 (The Observed Change in Interannual Variations of January Minimum Temperature between 1951-1980 and 1971-2000 in South Korea)

  • 정재은;정유란;윤진일;최동근
    • 한국농림기상학회지
    • /
    • 제6권4호
    • /
    • pp.235-241
    • /
    • 2004
  • 1월의 최저기온을 대상으로 1951년부터 2000년까지 14개 지점의 관측자료를 분석한 결과 11개 지점에서 전반기(1951-1980)에 비해 후반기(1971-2000)의 연차 변이가 오히려 감소한 것으로 나타났다 표준편차로 표현할 경우 제주, 전주, 울릉도를 제외한 나머지 11개 지점에서 많게는 0.35(서울)에서 적게는 0.03(강릉)까지 고르게 연차변이가 감소하였다. 이는 최근의 난동화 경향과 함께 겨울철 최저기온의 연차변이가 더 심해지고 있다는 당초의 예상과 다른 결과이다 연차변이의 공간분포양상은 최저기온의 절대값과 정의 상관을, 관측점의 해발고도와는 부의 상관을 보였다. 이 관계를 이용하여 남한전역의 1월 최저기온 30년 표준 편차 분포도를 작성하였으며, 이를 토대로 재현기간별로 기대되는 전국의 극최저기온 분포도를 제작하여 지역별 동해위험 평가에 이용토록 하였다.

수확기 동상해 피해가 '부유' 단감의 저장 품질에 미치는 영향 (Effect of Freeze Injury by Weather on Quality of 'Fuyu' Sweet Persimmon at Harvest and Subsequent Storage)

  • 조윤희;최성태;김성철;김은경;황연현;김은석;안광환
    • 한국포장학회지
    • /
    • 제21권2호
    • /
    • pp.73-78
    • /
    • 2015
  • 단감은 수확 전 저온에 노출되는 경우가 종종 발생하며, 저온에 노출된 단감은 수확 후 저장 품질이 저하될 우려가 있다. 본 연구는 수확시기별 단감 과원의 기온이 '부유' 단감의 저장 품질에 미치는 영향을 조사하였다. 10월 중순에서 11월 중순 사이에 단감 과원의 기온변화를 관찰한 결과, 단감의 동상해를 유발하는 온도의 $-2.1^{\circ}C$ 이하의 저온이 과수원에 5회 내습하였으며, 그 중 11월 19일 $-5.4^{\circ}C$로써 수확기 중 가장 낮은 기온을 기록하였다. $0^{\circ}C$의 저장고에서 150일 저장하는 동안, 세 처리구 중 3차 수확단감은 1, 2차와 비교하여 지속적으로 높은 a값을 유지하였지만 L값과 경도는 감소함에 따라서 이는 동상해 피해 증상으로 인한 품질저하로 판단된다. 반면에, 1차 수확단감은 저장기간 중 a값의 증가와 높은 경도를 일정하게 유지하여 수확 후 저장 중 후숙에 의한 변화로 보였다. 또한, 유리당 함량 변화에서 1, 2차 수확단감은 fructose, glucose 및 sucrose 모두 비슷한 수준을 유지하는 반면에 3차 수확단감은 fructose와 glucose 증가 및 sucrose 감소하는 경향을 보여주었다. 결론적으로, 기온저하가 급작스럽게 발생할 수 있는 11월 중순은 수확 및 저장 과실 품질 저하를 유도할 수 있어 적합하지 않는 시기이므로, 이 시기 전에 수확을 완료할 수 있도록 수확시기를 결정하는 것이 적합한 것으로 사료된다.

  • PDF