• Title/Summary/Keyword: Freezing temperature

Search Result 909, Processing Time 0.031 seconds

The Effects of Injection Molding Conditions of Polypropylene on the Linear Shrinkage and Weight of Molded Parts (폴리프로필렌의 사출성형조건이 성형품의 선형수축률과 중량에 미치는 영향)

  • 유중학;김희송
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.322-329
    • /
    • 1995
  • Series of experimental work was performed to mold tensile specimens by using the injection molding machine Mold temperature, melt temperature and packing time were chosen as processing parameters for studying the effects of those conditions on the linear shrinkage of final product. Here, each processing variable was decided from the numerical simulation and resin manufacturer's suggested value. The effects of molding conditions on the linear shrinkage in flow direction of the resin were analyzed by measuring the parts 2, 10, 30 and 60 days after molding. As a result, the linear shrinkage increased with the higher mold and melt temperature, and the change of mold temperature has shown more influence. The linear shrinkage of polypropylene has been found to progress up to 30 day with the lapse of the time, and the amount of the linear shrinkage has shown to be between 2.14% and 2.75%. In addition, the effects of packing pressure on the weight has shown to be extremely significant up to freezing time, and proper packing time of the tensile specimen has been found to be 2.0 seconds.

Various Turf Covers for Kentucky bluegrass Growth and Spring Green-up

  • Lee, Sang-Kook
    • Weed & Turfgrass Science
    • /
    • v.2 no.3
    • /
    • pp.292-297
    • /
    • 2013
  • Winter turfgrass injury is one of the critical problems of many golf courses in Korea. Turfgrass loss from freezing injury due to low temperature leads to many types of damages including weed invasion, increased herbicide cost, increased soil erosion, and expensive re-establishment. Although Kentucky bluegrass (Poa pratensis L.) which is the most widely used among cool-season grasses in Korea is well known as cold tolerance species, freezing injuries to Kentucky bluegrass during winter are often found. Protecting the turfgrass crown is necessary to recover from low temperature stress in winter because shoots and roots can be recovered from the crown. Turf covers may protect the crowns from direct low temperatures and desiccation. Six different turf covers were installed to cover Kentucky bluegrass during a period of low temperatures. Turf covers had positive effects for spring green-up of Kentucky bluegrass based on the study. Applying any type of turf covers on Kentucky bluegrass resulted in an increase average and minimum temperature compared to the uncovered plot. Among turf covers, clear PVC film without holes produced the longest root length and the highest turfgrass quality.

An Experimental Study on Heat Transfer Characteristics in the LHSS for Cool Thermal Air Conditioning (저온공조용 잠열 축열조의 열전달 특성에 관한 실험적 연구)

  • Seo, I.H.;Koh, J.Y.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.11-19
    • /
    • 2000
  • In this study, the basic data which were required for development of LHSS(latent heat storage system) were experimentally obtained. Experiments were carried out under the following conditions. The initial temperatures of P.C.M. which were used by parameter is $5^{\circ}C,\;9^{\circ}C$ and $14^{\circ}C$. The conditions of working fluid are $-6^{\circ}C,\;-4^{\circ}C$, and $65{\ell}$/min.. The pure water of which the freezing point is $0^{\circ}C$ was filled in the system, and the Ethylene glycol(brine) was circulated through the 10 vertical tubes as a secondary fluid in order to cool the P.C.M. down. The inlet temperature of the secondary fluid and the initial temperature of the water were varied to investigate the effects of the important design parameters. The phenomenons of temperature conversion of P.C.M. were appeared for the conductive heat transfer and free convective heat transfer by buoyancy force in this storage unit system. In order to find the effective water circulation path, we obtained P.CM. temperature distributions of 5 parts in the storage tank during freezing process.

  • PDF

Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Lee, Il-Sun;Baek, Dae-Hyun;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring (수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착)

  • Kang, Chae-Dong;Son, Kwon;Baek, Jong-Hyun;Hong, Hee-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

Adhesion of Ice Slurry in a Multi-component Aqueous Solution with Stirring and Cooling (다성분계 수용액의 교반/냉각에 의한 빙부착)

  • 강채동;강용태;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1063-1070
    • /
    • 2002
  • To resist ice adhesion on cooling wall is concerned to continuous ice formation in thermal storage system. In this study, ice slurries were formed with two ecological aqueous solution, one is ethanol+silanol and the other is propylene glycol+silanol. By freezing under stirring the solution of $300m\ell$ in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, the shape of ice slurry and the strength of ice adhesion on wall was observed with measuring the temperature and stirring load variation. As the concentration is smaller and the supercooling degree is larger, the ice adhesion is easy to occur. When the stirring load is larger than$ 2.1\times10^{-5}W$, the ice adhesion occurred.

An Fundamental Study of on Freezing Characteristics of Antarctic Soil (남극 대륙기지 건설지에서 채취한 흙시료의 동결특성에 관한 기초연구)

  • Hong, Seung-Seo;Kim, Young-Seok;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1030-1038
    • /
    • 2010
  • In order to design and construction of the Antarctic Continental Station at the Terra Nova Bay in the East Antarctic, ground characteristics for soil samples taken from the Antarctic. A series of laboratory tests were performed to investigate the variations of the thermal conductivity, the unfrozen water content according to the temperature change of the soil taken from the Antarctic. The temperature were low down below zero.

  • PDF

A Study on the Effect of Surfactant on the Freezing of Aqueous Solution (수용액의 동결에 영향을 미치는 계면활성제의 효과에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.694-698
    • /
    • 2007
  • This present study has dealt with the effect of surfactant on the freezing of aqueous solution Sodium chloride aqueous solution was used to measure the effect of surfactant and the main parameters of this experiment were temperature of bath, revolution of stirrer. and the radial velocity of NaCl solution. The acquired main conclusions are as follows; 1) the lower super-cooling temperature make hardly to attach the ice on beaker, 2) the size of ice become smaller to add the surfactant, 3) the ice packing factor increase with increasing of stirrer revolution.

Formation and Dissociation Processes of Gas Hydrate Composed of Methane and Carbon Dioxide below Freezing

  • Hachikubo, Akihiro;Yamada, Koutarou;Miura, Taku;Hyakutake, Kinji;Abe, Kiyoshi;Shoji, Hitoshi
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.515-521
    • /
    • 2004
  • The processes of formation and dissociation of gas hydrates were investigated by monitoring pressure and temperature variations in a pressure cell in order to understand the kinetic behavior of gas hydrate and the controlling factors fur the phase transition of gas hydrate below freezing. Gas hydrates were made kom guest gases ($CH_4,\;CO_2$, and their mixed-gas) and fine ice powder. We found that formation and dissociation speeds of gas hydrates were not controlled by temperature and pressure conditions alone. The results of this study suggested that pressure levels at the formation of mixed-gas hydrate determine the transient equilibrium pressure itself.

The Construction and Investigation of The 1/4 Wavelength Thermoacoustic Refrigerator (1/4파장 열음향 냉동기의 제작 및 성능시험)

  • Song, Kyu-Joe;Park, Jong-Ho;Lee, Sung-Ro;Lee, Jae-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.223-228
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, The thermoacoustic refrigerator were constructed. The apparatus is capable of driving closed systems containing He or air at mean pressures ranging from 1-9.3 bar, at frequencies ranging from 100-1000Hz. The resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, The resonance tube is 340.5mm in length. In case of using air as a coolant. Freezing frequency is 174Hz, In case of using He as a coolant Freezing frequency is 625Hz. Using He, The cold-part temperature of the heat exchanger fell to $-23.7^{\circ}C$ after 120 minutes in 70W.

  • PDF