• Title/Summary/Keyword: Freezing Filtration

Search Result 9, Processing Time 0.023 seconds

Rapid Determination of Chlorostyrenes in Fish by Freezing-Lipid Filtration, Solid-Phase Extraction and Gas Chromatography-Mass Spectrometry

  • Kim, Min-Sun;Park, Kwang-Sik;Pyo, Hee-Soo;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.352-356
    • /
    • 2008
  • An analytical method has been developed for measuring chlorostyrenes in fish tissue sample. Extraction of chlorostyrenes from fish tissue was carried out by ultrasonication using acetone/n-hexane (5:2, v/v) mixture. Most of the lipids in the extract were eliminated by freezing-lipid filtration, prior to solid-phase extraction (SPE) cleanup. During freezing-lipid filtration, about 90% of the lipids extracted from the fish samples were easily removed without any significant losses of chlorostyrenes. For purification, SPE using Florisil was used for the rapid and effective cleanup. Quantification was performed using gas chromatography-mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery was above 80% in the spiked fish tissue sample at 10 and 100 ng/g levels, respectively. The detection limits for chlorostyrenes were ranged from 0.05 to 0.1 ng/g. This developed method is demonstrated to give efficient recoveries and LODs for detecting chlorostyrenes spiked into fish tissue with high lipid content.

Dertermination of Alkylphenols, Chlorophenols and Bisphenol A in Various Samples by Freezing Filtration and GC/MS-SIM

  • Kim, Hyub
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.68.1-68.1
    • /
    • 2003
  • A method for determination 11 endocrine disrupting chemicals of phenols in various samples was deloped. The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization method and tert-butyldimethylsilyl (TBDMS) derivatization method. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at -60$^{\circ}C$ for 2 hours (freezing filtration). (omitted)

  • PDF

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.26 no.9
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.

Application of Freezing Filtration Method to the Analysis of Alkylphenols, Chlorophenols and Bisphenol a in Korean Aquatic Biological Samples Using GC/MS-SIM (GC/MS-SIM을 이용한 우리나라 수중 생물시료 중 알킬페놀, 클로로페놀과 비스페놀 A의 분석을 위한 냉동필터법의 응용)

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples. The alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at $-60^{\circ}C$ for 2 hours(freezing filtration method). Also, solid-phase extraction(SPE) was used to XAD-4 and subsequent conversion to isobutoxycarbonyl(isoBOC) or tert-butyldimethylsilyl(TBDMS) derivatives for sensitive analysis with gas chromatography/mass spectrometry-selected ion monitoring(GC/MS-SIM) mode. For isoBOC derivatization and TBDMS derivatization the recoveries were $70.1\sim150.6%$ and $93.8\sim108.3%$, the method detection limit(MDLs) of bisphenol A for SIM were $0.062{\mu}g/kg$ and $0.010{\mu}g/kg$, and the SIM respectively. When these methods were applied to korean aquatic biological samples, the concentrations of the 11 phenolic EDCs were $0.675\sim1.970{\mu}g/kg$.

An analytical method of heterocyclic amines by LC/MS (LC/MS를 이용한 heterocyclic amines의 분석법)

  • Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.115-123
    • /
    • 2007
  • The heterocyclic amines (HAs) are a family of mutagenic/carcinogenic chemicals formed from the cooking of muscle meats such as beef, meat, fowl, and fish. A major draw back in the analysis of HAs from foods is their very low level of concentration (ng/g) and a number of matrix interferences in samples. Solid-phase extraction (SPE) is one of the procedures widely used for the extraction and purification of HAs in food samples. In this study, several SPE procedures of HAs determination were performed. Recoveries of the HAs were obtained from comparing a matrix such as a standard methanolic solution and pre-cooked meat extracts. Recovery values were ranging between 25.3 and 93.0 % at a concentration of 25.0 ng/g. HAs were determined with high sensitivity by micro-HPLC (${\mu}$-HPLC) analysis with electrospray ionization mass spectrometry (ESI-MS). Another developed method, which is freezing filtration method, shows better extraction recoveries and good precisions. The established method will be applicable to monitoring of heterocyclic amines from the cooked meat.

The Effect of Freezing and Filter Cake Drying Process on the Preparation of Ba-Ferrite by Coprecipitation (동결 및 Filter Cake 건조과정이 공침법에 의한 Ba-ferrite제조에 미치는 영향)

  • 이병우;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.1 no.1
    • /
    • pp.100-106
    • /
    • 1991
  • Ba.Fe - hydroxide precipitates were obtained by the variation of pH levelsm, which process was based on the calculated solubility from the solubility product(Ksp). Single phase $BaFe_12O_19$ was synthesized above $790^{\circ}C$. The 98% of theoretical density was obtained in the specimens formed from the filter cake drying and the hand pressing at temperatures $95^{\circ}C$ and $1,100^{\circ}C$ for 2hrs, respectively. The feezing of colloidal coprecipitate suspension formed powders up to several tens of micron size, which led to reduce the filtration time and the consumption of distilled water.

  • PDF

Post-thaw Thermal Resistance Test on Motility and Acrosomal Integrity of Filtered and Non-filtered Frozen Semen of Murrah Buffalo Bulls

  • Maurya, V.P.;Tuli, R.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.10
    • /
    • pp.1424-1428
    • /
    • 2003
  • Present investigation was conducted to determine the post-thaw sperm motility and acrosomal damage of filtered and non-filtered frozen semen of Murrah buffalo bulls. Twenty semen ejaculates (from four Murrah buffalo bulls collected at weekly interval) were diluted in Tris egg yolk glycerol extender and divided into two parts. One was filtered through sephadex G-100 column and the other portion was kept as such (non-filtered). Both fractions were frozen in liquid nitrogen ($-196^{\circ}C$) by the standard method developed in the laboratory. After 24 h of freezing, non-filtered and filtered semen samples were thawed at $37^{\circ}C$ for 1 min. These samples were incubated at $37^{\circ}C$ in a water both. The different seminal characteristics i.e. percent progressive sperm motility, live and abnormal spermatozoa and spermatozoa with damaged acrosome were assessed at hourly interval till they remained motile. The filtered frozen and thawed semen showed significantly (p<0.05) high sperm viability and acrosomal integrity as compared to non-filtered semen.

Determination of Trichlorfon Pesticide Residues in Milk via Gas Chromatography with μ-Electron Capture Detection and GC-MS

  • Hem, Lina;Khay, Sathya;Choi, Jeong-Heui;Morgan, E.D.;El-Aty, A.M. Abd;Shim, Jae-Han
    • Toxicological Research
    • /
    • v.26 no.2
    • /
    • pp.149-155
    • /
    • 2010
  • The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with ${\mu}$-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dichloromethane was dissolved in ethyl acetate for gas chromatography. Recovery concentration was determined at 0.5, 1.0, and 2.0 of times the maximum permitted residue limits (MRLs) for trichlorfon in milk. The average recoveries (n = 6) ranged from 92.4 to 103.6%. The repeatability of the measurements was expressed as relative standard deviations (RSDs) ranging from 3.6%, to 6.7%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.7 and $11.1{\mu}g/l$, respectively. The accuracy and precision (expressed as RSD) were estimated at concentrations from 25 to $250{\mu}g/l$. The intra- and inter-day accuracy (n = 6) ranged from 89.2% to 91% and 91.3% to 96.3%, respectively. The intra- and inter-day precisions were lower than 8%. The developed method was applied to determine trichlorfon in real samples collected from the seven major cities in the Republic of Korea. No residual trichlorfon was detected in any samples.