• Title/Summary/Keyword: Free-drop Test

Search Result 86, Processing Time 0.028 seconds

Study on the Lapping Characteristics of Sapphire Wafer by using a Fixed Abrasive Plate (고정 입자 정반을 이용한 사파이어 기판의 연마 특성 연구)

  • Lee, Taekyung;Lee, Sangjik;Jo, Wonseok;Jeong, Haedo;Kim, Hyoungjae
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.44-49
    • /
    • 2016
  • Diamond mechanical polishing (DMP) is a crucial process in a sapphire wafering process to improve flatness and achieve the target thickness by using free abrasives. In a DMP process, material removal rate (MRR) is a key factor to reduce process time and cost. Controlling mechanical parameters, such as velocity and pressure, can increase the MRR in a DMP process. However, there are limitations of using high velocities and pressures for achieving a high MRR owing to their side effects. In this paper, we present the lapping characteristics and improvement of MRR by using a fixed abrasive plate through an experimental study. The change in MRR as a function of velocity and pressure follows Preston's equation. The surface roughness of a wafer decreases as the plate velocity and pressure increases. We observe a sharp decrease in MRR over the lapping time at a high velocity and pressure in the velocity and pressure test. An analysis of surface roughness (Rq and Rpk) indicates that wear of abrasives decreases the MRR sharply. In order to investigate the effect of abrasive wear on the MRR, we utilize a cutting fluid and a rough wafer. The cutting fluid delays the wear of abrasives resulting in improvement of MRR drop. The rough wafer maintains the MRR at a stable rate by self-dressing.

Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

  • De Oliveira, Greison Rabelo;Pozzer, Leandro;Cavalieri-Pereira, Lucas;De Moraes, Paulo Hemerson;Olate, Sergio;De Albergaria Barbosa, Jose Ricardo
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.217-223
    • /
    • 2012
  • Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.

SHOCK-ABSORBING BEHAVIOR OF TEMPORARY SOFT DENTURE LINERS (임시 연성 의치상 이장재의 충격 흡수에 관한 연구)

  • Chun, Yong-Suk;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.151-167
    • /
    • 1996
  • Temporary soft liners can be used to prevent chronic soreness from dentures or to aid in its treatment are as adjuncts in tissue conditioning, for temporary obturators, and to stabilize baseplate or surgical stent. The purpose of this study was to evaluate the shock absorption properties of several temporary soft denture liners using a free drop test with an accelerometer. The materials tested inclued Coe-comfort, Softone, Tissue conditioner and Viscogel. The specimens were fabricated with the thickness of 1, 2, 3mm and were stored in distilled water at $37^{\circ}C$ for a day, 1, 2, and 3 weeks. Six samples were made with each material for each test condition and the shock-absorbing behavior was evaluated according to material, thickness and duration. The results were as following : 1. Softone of 3mm thickness stored for a day showed the most excellent shock absorbability. 2. The shock absorbing behavior of duration according to materials and thickness showed a day to be the highest and decreased in 1 week, 2 weeks and 3 weeks in that order(p<0.05). And there was no significant difference between durations in Tissue conditioner. 3. The shock absorbability of thickness according to materials and duration showed 3mm to be highest and decreased in the order of 2mm, 1mm(p<0.05). 4. In comparison of the shock absorbability of temporary soft denture liners according to thickness, there was statistically significant difference between Softone and Visocgel, Tissue conditioner, Coe-comfort / Viscogel and Tissue conditioner, Coe-comfort in 1,2mm thickness, and between Softone, Viscogel and Tissue conditioner, Coe-comfort in 3mm thickness (p<0.05).

  • PDF

Study on the Shape of Appendage for the Reduction of Motion of Floating Wind Turbine Platforms (부유식 풍력 하부구조물의 운동 저감을 위한 부가물 형상 연구)

  • Dae-Won Seo;Jaehyeon Ahn;Jungkeun Oh
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1201-1208
    • /
    • 2022
  • In general, to maximize the supply and efficiency of floating offshore wind power generation energy, the motion caused by wave attenuation of the substructure must be reduced. According to previous studies, the motion response was reduced due to the vortex viscosity generated by the damping plate installed in the lower structure among the waves. In this study, a 5 MW semi-submersible OC5 platform and two platforms with attenuation plates were designed, and free decay experiments and numerical calculations were performed to confirm the effect of reducing motion due to vortex viscosity. As a result of the model test, when the heave free decay tests were conducted at drop heights of 30 mm, 40 mm, and 50 mm, compared with the OC5 platform, the platform with two types of damping plates attached had relatively improved motion damping performance. In the model test and numerical calculation results, the damping plate models, KSNU Plate 1 and KSNU Plate 2, were 1.1 times and 1.3 times lower than OC5, respectively, and the KSNU Plate 2 platform showed about two times better damping performance than OC5. This study shows that the area of the damping plate and the vortex viscosity are closely related to the damping rate of the heave motion.

Improvement of Pregnancy Rates by Coculture of Human Embryos with Cumulus Cells in Glucose and Phosphate Free M-TALP Media (Glucose와 Phosphate가 제거된 M-TALP 배지에서의 난구세포 공배양에 의한 임신율 향상에 관한 연구)

  • Chung, B.S.;Chang, W.H.;Lee, M.H.;Kim, J.Y.;Bang, J.H.;Kim, K.H.;Suh, T.K.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.1
    • /
    • pp.75-81
    • /
    • 1999
  • The beneficial effect of glucose and phosphate ions in culture medium on the development of human embryos in vitro has not been fully elucidated. The purpose of this study was to evaluate the influence of fertilization and culture of embryos in glucose/phosphate-free m-TALP medium on pregnancy rates in IVF-ET program. The patients in 244 IVF-ET cycles received GnRH agonist + HMG regimens. A does of 10,000 IU HCG was administered when two or more dominent follicles reached 18mm in diameter. Thirty-six hours after HCG, oocytes were recovered transvaginally using ultrasound guidance. Aspirated oocytes were matured for 4 to 6 h in TCM-199 supplemented with 10% follicular fluid (FF). Insemination was carried out with 50,000 motile spermatozoa in TCM-199 + 10% FF or m-TALP + 5% FF + 5% fetal cord serum (FCS) according to experimental design. After 6 h, oocytes were washed 3 to 4 times and cultured in each fresh medium. After 20 h, oocytes were freed from cumulus/corona cells and examined for the presence of pronuclei. Fertilized oocytes were transferred into each co-culture drops and cultured for further incubation. On day 3, embryo transfer was performed with grade 1 and 2 embryos. Monolayers for co-culture of embryos were prepared by plating $1{\times}10^5$ cumulus cells/ml in 10ul drop of TCM-199 + 10% FF or m-TALP + 5% FF + 5% FCS media 24 h prior to the onset of co-culture. Development to 4 to 16 cell stage was observed at 70x magnification following two days of incubation. Pregnancy was confirmed by detecting increasing serum ${\beta}$-hCG concentrations for 11 days following embryo transfer. Data were analyzed by ${\chi}^2$-test. Oocytes from 244 IVF-ET cycles were randomized. The number of cycles and mean age of patients were 97 and 147, 31.3 yrs and 31.2 yrs for TCM-199 (control) and m-TALP groups, respectively. The mean number of retrieved oocytes/cycle, fertilization rates, number of embryos transferred/ET and pregnancy rates were 11.1 and 10.3, 65.1% and 67.3%, 4.1 and 4.7, 28.9% and 43.8% for TCM-199 and m-TALP groups, respectively. Differences in the pregnancy rates were found between control and m-TALP groups (p<0.05). The pregnancy rate of patients divided according to maternal age groups of ${\leq}30$, 31-35, $36{\leq}$ were 44.4% and 49.0%, 26.1% and 41.3%, 29.2% and 41.2% for control and m-TALP groups, respectively. These data indicate that culture of human embryos in glucose/phosphate-free m-TALP medium improves pregnancy rates.

  • PDF

Electrochemical Ion Migration Sensitivity of Printed Circuit Board Plated with Sn-3.0Ag-0.5Cu and Sn-37Pb (Sn-3.0Ag-0.5Cu, Sn-37Pb 표면처리 기판의 전기화학적 이온 마이그레이션 민감도)

  • Hong, Won-Sik;Park, No-Chang;O, Cheol-Min;Kim, Gwang-Bae
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.136-138
    • /
    • 2006
  • Recently a lots of problems have observed in high densified and high integrated electronic components. One of them is ion migration phenomena, which induce the electrical short of electrical circuit. Ion migration phenomena has been observed in the field of exposing the specific environment and using for a long time. Also as the RoHS restriction was started in July 1st, 2006, Pb-free solder was utilized in electronics assemblies. In this case, it is very important to compatible between components and printed circuit board(PCB), thus surface treatment materials of PCB was changed to Sn, Sn-3.0Ag-0.5Cu, Cu. Therefore these new application become to need to reevaluate the sensitivity about electrochemical ion migration. This study was evaluated the occurrence time of electrochemical ion migration using by water drop test. We utilized PCB(printed circuit board) having a comb pattern as follows 0.1, 0.318, 0.5, 1.0 mm pattern distance. Sn-3.0Ag-0.5Cu and Sn-37Pb were electroplated on the comb pattern. 6.5V and 15.0V were applied in the comb pattern and then we measured the electrical short time causing by occurring the ion migration. In these results, we evaluate the sensitivity and derived the prediction models of ion migration occurrence time depending on the pattern materials, applied voltage and pattern spacing of PCB conductor.

  • PDF

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Manufacture of Black Color Zirconia Ceramics Used by Eco-Friendly Materials (친환경 재료를 사용한 흑색 지르코니아 세라믹스 제조)

  • Joo, In-Don;Lee, Byung-Ha
    • Korean Journal of Materials Research
    • /
    • v.21 no.12
    • /
    • pp.685-689
    • /
    • 2011
  • The goal of this investigation was to produce a zirconia-family black ceramics that has enhanced functionality and reliability. Color zirconia ceramics have been produced by adding pigments. Pigments cause structural defects within zirconia and result in a drop in physical properties. Using environmentally friendly rice husk, we produced a black zirconia that is free of structural defects. In optimal firing conditions for black zirconia the calcining temperatures of the molding product are changed from $400^{\circ}C$ to $1200^{\circ}C$, and the firing temperatures are changed from $1400^{\circ}C$ to $1600^{\circ}C$. Color of testing the specimens was analyzed using Ultraviolet (UV) spectroscopy. Scanning Electron Microscope (SEM), EDAX (EDX), and Fourier transform infrared spectroscopy (FT-IR) analyses were carried out in order to examine impregnation properties and crystal phases. Universial Test Machine (UTM) was used to measure the flexual strength as well as the compressive strength. From experimental results, it was found that in optimal firing conditions the sample was calcined from $1000^{\circ}C$ to $1500^{\circ}C$. Commission internationalde I'Edairage (CIE) values of manufactured black zirconia color were $L^*$ = 29.73, $a^*$ = 0.23, $b^*$ = -2.68. The bending strength was 918 MPa and the compressive strength was 2676 MPa. These strength values are similar to typical strength values of zirconia, which confirms that carbon impregnation did not influence physical properties.

A Study on Slamming Impact Pressure by a Numerical Method based on the Cartesian-grid System (직교격자계 기반의 수치계산법을 이용한 슬래밍 충격압력의 연구)

  • Kim, Ki-Yong;Lee, Young-Gill;Ha, Yoon-Jin;Kang, Ui-Ha;Park, Jeong-Ho;Lee, Sun-Kyu;Lee, Chang-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.308-315
    • /
    • 2019
  • In this study, numerical simulations of slamming impact pressure acting on the flat plate and wedge type models using the cartesian-grid system and Modified Marker-Density Method (MMD method) were performed and the results were examined. The flat plate and wedge type models were selected as target objects, the turbulence characteristics were considered by applying the Sub-Grid Scale (SGS) turbulence model. Through this study, how the pressure acting on the target objects according to the incident angle influences the slamming impact pressure was examined and the results were compared with the flow characteristics of other experimental results. Also, the degree of slamming impact pressure is evaluated with respect to the cartesian-grid system and MMD method, which is easy to use and has a high degree of calculation for free surface.

Intraoperative near-infrared spectroscopy for pedicled perforator flaps: a possible tool for the early detection of vascular issues

  • Marchesi, Andrea;Garieri, Pietro;Amendola, Francesco;Marcelli, Stefano;Vaienti, Luca
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.457-461
    • /
    • 2021
  • Background Pedicled perforator flaps can present postoperative complications similar to those encountered in free flap surgery. Beyond a clinical evaluation, there is still no reliable technical aid for the early prediction of vascular issues. The aim of this study was to assess the support of near-infrared spectroscopy technology as an intraoperative tool to anticipate postsurgical flap ischemia. Methods We prospectively enrolled 13 consecutive patients who were referred to our hospital from March 2017 to July 2018 and required a reconstructive procedure with a pedicled fasciocutaneous perforator flap. We measured flap peripheral capillary oxygen saturation (SpO2) in each patient with a Somanetics INVOS 5100C Cerebral/Somatic Oximeter (Medtronic), both before and after transposition. Patient demographics, operative data, and complications were then recorded during the following 6 months. We analyzed the data using the Wilcoxon signed-rank test and linear regression. Results The mean flap SpO2 before and after transposition was 92%±3% and 78%±19%, respectively. The mean change in SpO2 was 14%±17%, with a range of 0% to 55%. The change in saturation and mean saturation ratio were significantly different between patients with and without postoperative flap necrosis. Conclusions An immediate quantitative analysis of flap peripheral capillary SpO2 after transposition has never before been described. In our experience, an intraoperative drop in SpO2 equal to or greater than 15%-20% predicted vascular complications in pedicled perforator flaps. Conversely, flap size and rotation angle were not correlated with the risk of flap necrosis.