• 제목/요약/키워드: Free cooling

검색결과 265건 처리시간 0.027초

액체를 사용하지 않는 초전도시스템의 개발 동향 (Current Status of Liquid-Free Superconducting System Develo)

  • 장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.1-6
    • /
    • 1999
  • The recent progress in the new cooling technology for superconducting systems without liquid cryogens is briefly presented. In these conduction-cooled systems, the super-conducting magnets are cooled by a direct contact with closed-cycle cryocoolers and only electricity is supplied to maintain the cryogenic temperatures. It is reported that at least 20 conduction-cooled (low Tc or high Tc) super- conducting systems have been constructed, tested, or commercially used worldwide. Some of the significant design issues are discussed in comparison with the conventional liquid-helium cooled systems.

  • PDF

Linear compressor 스터링 냉동기 설계에 관한 연구 (Design of the Linear Compressor Stirling Cryocooler)

  • 박성제;고득용;홍용주;김효봉
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.81-84
    • /
    • 2000
  • This paper presents operating process and design method on the linear compressor Stirling cryocooler for cooling infrared detector. The free piston-type Stirling cryocooler, which applies 1) the Stirling cycle for refrigeration, 2) linear motors for driving, 3) flexure bearings for support systems, and 4) fine gap for clearance seals, is the most suitable design for a mechanical cryocooler utilized in a night vision environment.

  • PDF

온도변화로 인해 고분자 박막에 발생하는 열응력 해석 (Analysis of Thermal Stresses Induced in Polymeric Thin Layer Due to Temperature Change)

  • 이상순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.146-152
    • /
    • 2002
  • In this study, the singular thermal stresses induced during cooling down from high temperature to room temperature have been analyzed for the viscoelastic thin layer. The time domain boundary element method has been employed to investigate the behavor of stresses for the whole interface. Within the context of a linear viscoelastic theory, a stress singularity exists at the point where the interface between the elastic substrate and the viscoelastic thin layer intersects the free surface.

  • PDF

고분자 박막에서의 열응력 해석 (Analysis of Thermal Stresses in Polymeric Thin Film)

  • 이상순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.389-394
    • /
    • 2003
  • In this study, the stress singularity factors generated during cooling down from high curing temperature to room temperature have been analyzed for the viscoelastic thin film. The time domain boundary element method has been employed to investigate the behavior of stresses for the whole interface. Within the context of a linear viscoelastic theory, a stress singularity exists at the point where the interface between the elastic substrate and the viscoelastic thin film intersects the free surface.

  • PDF

초전도 필터 냉각용 선형압축기형 맥동관 냉동기의 실험적 연구 (An Experimental Study of the Pulse Tube Cryocooler with the Linear Compressor)

  • 박성제;홍용주;김효봉;고득용;염한길;김양훈;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.197-201
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stirling cryocooler and inertance pulse tube cryocooler for the cooling infrared detector and cryosensor are currently under development at Korea Institute of Machinery & Materials. The pulse tube cryocooler, which has no moving parts at its cold section, is attractive for obtaining higher reliability, simpler construction and lower vibration than in any other small cryocoolers. In recent years, pulse tube cryocoolers have experienced a rapid development with the aim to eventually replace Stirling and Gifford-McMahon cryocoolers in various applications. In this study, operating characteristics of the conventional linear Stirling cryocooler was investigated by experiment. And, inertance pulse tube cryocooler with the commercial linear compressor(Leybold Polar) was designed, manufactured, and tested by the variations of the operating frequency, charging pressure and input power.

  • PDF

맞대기 용접시의 각변형 거동에 관한 연구 (Behavior of angular distortion in butt joint welding of thin plate structure)

  • 배강열;김희진
    • Journal of Welding and Joining
    • /
    • 제6권3호
    • /
    • pp.21-26
    • /
    • 1988
  • The behavior of angular distortion in butt joint wleding of thin plate structure is investigated with an experimental model and partially with a computational model. The experimental model studying the effects of specimene size and degree of restraint on the angular distorion offers a good method for analyzing the behavior of the distrotion. In addition, the distrotion during welding was demonstrated by both experimental measurement and numericla prediciton. The facts evealed in this study are as follows : 1) distrotion angles were changed with variations of specimene wldth. 2) With the restraint, angular distrotion was reduced to 20% to that of free joint. 3) After the restraint being removed, the effect of restraint was also remained. 4) Same heat input per unit thickness caused same amount of distortion. 5) The mode of angular distortion was expected to be changed with expected to be changed with time, i.e. convex movement during heating and concave one during cooling.

  • PDF

작동주파수와 연결관 길이 변화가 스터링 냉동기의 성능에 미치는 영향 (The effect of the operating frequency and the length of the split tube on the performance for the Stirling cryocooler)

  • 김효봉;박성제;홍용주;고득용;김종학;유병건;박종호
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.55-61
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at korea Institute of Machinery & Materials. The FPFD Stirling cryocooler consists of two compressor pistons driven by linear motors which make pressure waves and a pneumatically driven displacer piston with regenerator. It is the most suitable design for a mechanical cryocooler utilized in night vision environment In this study, performance test of the Stirling cryocooler with different length of the split tube and operating frequency were performed to get characteristics of the cryocooler.

  • PDF

제강 슬래그를 이용한 콘크리트의 동결융해에 대한 실험적 연구 (An Experimental Study on the Freezing and Thawing of Concrete Mixed with Steel Slag)

  • 정원섭;조성현;권기주;박성우;김진만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.48-53
    • /
    • 2003
  • The steel slag, a by-product which is produced on the process of manufacturing steel by refining pig iron is mainly used as road materials after aging it. It is necessary to age steel slag for long time in air because the reaction with water and free-CaO in steel slag could make the volume expanded. Due to this reason it prevents steel slag from being used as aggregate of concrete. But steel slag used in this study is controled by a air-jet method which rapidly cools substance melted at a high temperature. Rapid cooling prevents from generating of free-CaO in steel slag. In this study, it was investigated that steel slag manufactured by air-jet method affects on concrete in the freezing and thawing. As results of this study, concrete mixed with steel slag was worse in the freezing and thawing than concrete mixed with sand in spite of using air entraining agent. To obtain durability of concrete in the freezing and thawing, it is desirable to mix 50% of steel slag in concrete per unit weight of volume.

  • PDF

초기응력을 갖는 차세대 광디스크의 진동 특성 (Vibration Characteristics of a New Optical Disk with Initial Stress)

  • 김재관;이승엽
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2513-2519
    • /
    • 2000
  • Free vibration characteristics of an initially stressed CD/DVD disk, which is designed for increasing critical speeds of current optical disks, are analyzed using the Rayleigh-Ritz technique based on variational formulations. Natural frequencies of the new disk depend on membrane stresses caused by disk rotation as well as residual stresses imposed during the cooling process of the injection molding. Critical speeds are calculated for the various initial patterns of radial and circumferential stresses. Initially imposed tensile stresses increase the natural frequencies of all the vibration modes except zero nodal diameter mode, whose natural frequency is independent of circumferential stress. A new disk with initial tensile stress of 0.5MPa is shown to have its critical speed about 30 % higher than the current optical disk.

단일 원형관-원형휜 열교환기의 자연대류 열전달 실험관계식 (Free Convection Correlation for the Single Circular Finned Tube Heat Exchanger)

  • 강희찬;장현순
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.596-600
    • /
    • 2008
  • An experimental study has been conducted on the free convection heat transfer for the 7 kinds of circular finned tube heat exchangers. Empirical correlation was suggested at the range of 3,500$D_o$/$D_i$<3.0, 0.19<$P_f$/$D_i$<0.34. The 92% of experimental data agreed with the correlation within 10%.

  • PDF