The effect of the operating frequency and the length of the split tube on the performance for the Stirling cryocooler

작동주파수와 연결관 길이 변화가 스터링 냉동기의 성능에 미치는 영향

  • Published : 2001.11.01

Abstract

A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at korea Institute of Machinery & Materials. The FPFD Stirling cryocooler consists of two compressor pistons driven by linear motors which make pressure waves and a pneumatically driven displacer piston with regenerator. It is the most suitable design for a mechanical cryocooler utilized in night vision environment In this study, performance test of the Stirling cryocooler with different length of the split tube and operating frequency were performed to get characteristics of the cryocooler.

Keywords

References

  1. Cryocoolers 8 Space Qualification Program of a Signal USFA Tactical Cooler for the Mars 1996 Apace Mission A. Cardin;D. Feger;D. Verbeek
  2. Cryocoolers 8 Linear Drive Stirling Cryocoolers:Qualification and Life Testing Results R. M. Rawlings;C. E. Granger Ⅲ;G. W. Hinrichs
  3. Cryocoolers 8 Dual Opposed Piston Stirling Cryocoolers for IR Systems R. Narayan
  4. Proceedings, KIASC Conference 2001, Mooju Study of Stirling Cryocooler Performance with different length of split tube Y. J. Hong;S. J. Park;D. Y. Koh;H. B. Kim;K. S. Oh;J. H. Kim
  5. Proceedings, KIASC Conference 2001, Mooju Study of KIMM-E1 Stirling Cryocooler Performance with different Charging Pressure S. J. Park;Y. J. Hong;D. Y. Koh;K. S. Oh;H. K. Yeom;J. H. Kim