The effect of the charging pressure and operating frequency in the Stirling Cryocooler

충전압력 및 작동주파수 특성 연구에 의한 스터링 냉동기 개발

  • 박성제 (한국기계연구원 열유체환경연구부) ;
  • 홍용주 (한국기계연구원 열유체환경연구부) ;
  • 김효봉 (한국기계연구원 열유체환경연구부) ;
  • 고득용 (한국기계연구원 열유체환경연구부) ;
  • 김양훈 (한국기계연구원 열유체환경연구부) ;
  • 유병건 (우영기술원) ;
  • 이기백 (부산대학교)
  • Published : 2001.11.01

Abstract

This paper presents manufacturing process and test results in the optimum pressure and operating frequency for the free piston free displacer(FPFD) Stirling cryocooler designed and manufactured by Korea Institute of Machinery &Materials (KIMM). FPFD Stirling cryocooler is currently under development uses opposed linear motors to drive opposed pistons . The performance of FPFD Stirling cryocooler is evaluated as a function fo charging pressure and operating frequency. In general as the operating frequency of the compressor is increaed but natural frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49K and cooling capacity of 0.5W at 7.2K.

Keywords

References

  1. Cryogenics 1994 v.34 no.5 Infrared Detector Requirements which drive Cryogenic Development R. E. McMurray
  2. Cryocoolers 8 Linear Drive Stirling Cryocoolers:Qualification and Life Testing Results R. M. Rawlings(etc.)
  3. Amnerican Chemical Society A Small Free-Piston Stirling Refrigerator A. K. De Jonge
  4. Korea-Japan Joint Workshop on Applied Superconductivity & Cryogenics An Experimental Study of Split-type Free Piston and Free Displacer Stirling Cryocooler S. J. Park(etc.)
  5. Korea-Japan Joint Workshop on Applied Superconductivity & Cryogenics A Simple Analysis of Split-type Free Piston and Free Displacer Stirling Cryocooler Y. J. Hong(etc.)