• Title/Summary/Keyword: Fracture-separation

Search Result 114, Processing Time 0.03 seconds

Hemorrhagic Shock in a Patient with a Morel-Lavallée Lesion Combined with Active Arterial Bleeding without Fracture

  • Lim, Eic Ju;Oh, Jong-Keon;Cho, Jae-Woo;Sakong, Seungyeob;Cho, Jun-Min
    • Journal of Trauma and Injury
    • /
    • v.34 no.1
    • /
    • pp.61-65
    • /
    • 2021
  • A Morel-Lavallée lesion is a closed degloving injury caused by traumatic separation of the skin and subcutaneous tissue from the underlying fascia. However, since physicians tend to focus on treating the bone fracture, hemodynamic instability accompanying a Morel-Lavallée lesion can sometimes be overlooked. We report the case of a hemodynamically unstable 73-year-old man who had a Morel-Lavallée lesion of the thigh, but no femur fracture. Angiography showed active bleeding from the muscular branch of the right deep femoral artery, which was then successfully embolized.

FRACTURE STRENGTH OF COMPOSITE RESIN WITH VARIOUS FIBER REINFORCING MATERIALS (수종의 섬유보강재가 복합레진의 파절강도에 미치는 영향)

  • Park, Ji-Man;Cho, Yong-Bum;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.371-380
    • /
    • 2000
  • The effect of fiber reinforcing materials on the fracture strength of composite resin was evaluated. Each ten composite resin bars reinforced by glassfiber[Fiber-Splint ML$^{(R)}$(Polydentia SA, Switzerland)], polyethylene fiber [Ribbond$^{(R)}$(Ribbond Inc., U.S.A.)] and polyaramid fiber[Kevlar$^{(R)}$(DuPont, U.S.A.)] were loaded under the 3-point compression technique. Another ten pure composite resin bars without reinforcement were used as a control group. Then mean fracture strength and standard deviation were calculated and a ANOVA and Scheffe test were used in statistics. The results were as follows: 1. Kevlar group showed the highest fracture strength as 175.5MPa (p<0.05). Fiber-Splint ML group showed the lowest fracture strength as 112.7MPa. 2. The mean value of fracture strength in Ribbond group was 136.4MPa, and that of unterated control group was 143.6MPa. No difference was found between the two groups. 3. Ribbond and Kevlar reinforcement groups showed a catastrophic failure, where complete separation of pieces occurs to a unseparated fracture pattern. The use of Kevlar reinforcement fibers with composite resin showed significant increase in the average load failure and the presence of the fibers did prevent the catastrophic crack propagation present in the unreinforced samples. The use of Ribbond reinforcement fibers with composite resin showed no significant increase in the average load failure. However, the presence of the fibers did prevent the catastrophic crack propagation. Because high strength of glassfiber are rapidly degraded on exposure to moisture and humidity. The use of Fiber-Splint ML reinforcement fibers with composite resin showed significant decrease in the average load failure and displayed catastrophic fractures.

  • PDF

Complete Separation of the Vertebral Body Associated with a Schmorl's Node Accompanying Severe Osteoporosis

  • Park, Seon Joo;Kim, Hyeun Sung;Kim, Hyun Sook;Kim, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.147-149
    • /
    • 2015
  • A Schmorl's node is defined as a simple endplate intravertebral herniation resulting from trauma or idiopathic causes. Although Schmorl's nodes have been considered clinically insignificant, they might indicate an active symptomatic process or cause serious complications. In this study, we report an interesting case of complete separation of a vertebral body caused by an untreated Schmorl's node accompanying severe osteoporosis. To our knowledge, this is the first clinical report in the published literature to evaluate the complete separation of a vertebral body associated with a Schmorl's node.

Electrical pulse separation of construction materials (전기적 펄스를 이용한 폐콘크리트로부터의 재생골재 분리 연구)

  • You, Kwang-Suk;Ahn, Ji-Whan;Fujita, Toyohisa;Han, Gi-Chon
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.05a
    • /
    • pp.109-112
    • /
    • 2005
  • The electrical pulse separation of concrete samples for the recycling purpose has been investigated by the electrical disintegration method using the discharged high voltageimpulse. First, when the consumed energy increased in electrical crushing, fracture section area increased clearly. This result suggests that crushing energy was consumed efficiently. Secondly, when conventional crushing after electrical disintegration is compared with only conventional crushing, gravels are more stable after electrical crushing. Thus, electrical crushing makes it easy to recover gravels from wasted concrete. In the next year, more efficient recovery of gravel for wasted concrete by electrical disintegration will be investigated. Thus, actual wasted concrete crushing by electrical separation and combination of conventional crushing will be carried out.

  • PDF

Dynamic Fracture Analysis at Strip with Composite Materials (복합재로 된 판재에서의 동적 파괴 해석)

  • Cho Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.265-270
    • /
    • 2006
  • When the dynamic crack propagates along the boundary at the strip with composite materials and tears apart it, the equivalent stress and strain, and the traction stress are investigated near its boundary. There are the maximum equivalent stress and plastic strain at the very seperated part and the maximum displacement at the bent part of the end of strip. The traction stress becomes higher as the separation distance becomes more. Its maximum value becomes 75 MPa as this distance becomes 0.015 mm. As this distance becomes more than 0.015 mm, this stress becomes lower. As this distance becomes more than 0.13 mm, the value of this stress becomes 0 constantly. This study aims at doing the basic study to provide the data necessary for the precise analysis of fracture intensity, the safety design and the development of advanced materials.

  • PDF

A new geomechanical approach to investigate the role of in-situ stresses and pore pressure on hydraulic fracture pressure profile in vertical and horizontal oil wells

  • Saberhosseini, Seyed Erfan;Keshavarzi, Reza;Ahangari, Kaveh
    • Geomechanics and Engineering
    • /
    • v.7 no.3
    • /
    • pp.233-246
    • /
    • 2014
  • Estimation of fracture initiation pressure is one of the most difficult technical challenges in hydraulic fracturing treatment of vertical or horizontal oil wells. In this study, the influence of in-situ stresses and pore pressure values on fracture initiation pressure and its profile in vertical and horizontal oil wells in a normal stress regime have been investigated. Cohesive elements with traction-separation law (XFEM-based cohesive law) are used for simulating the fracturing process in a fluid-solid coupling finite element model. The maximum nominal stress criterion is selected for initiation of damage in the cohesive elements. The stress intensity factors are verified for both XFEM-based cohesive law and analytical solution to show the validation of the cohesive law in fracture modeling where the compared results are in a very good agreement with less than 1% error. The results showed that, generally by increasing the difference between the maximum and minimum horizontal stress, the fracture pressure and its profile has been strongly changed in the vertical wells. Also, it's been clearly observed that in a horizontal well drilled in the direction of minimum horizontal stress, the values of fracture pressure have been significantly affected by the difference between overburden pressure and maximum horizontal stress. Additionally, increasing pore pressure from under-pressure regime to over-pressure state has made a considerable fall on fracture pressure in both vertical and horizontal oil wells.

Broden photographing method for Calcaneus Subtentaculum tali observation of Ankle plaster patient (발목부상을 당한 석고환자의 발꿈치뼈·목말받침돌기 관찰을 위한 Broden 촬영법 연구)

  • An, Byeongju
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • There is an Ankle Oblique(Broden' low) as an examination for the patient whose ankle was encased in orthopedic plaster. Some types of Ankle Joint coalition - Calcaneonavicular coalition, Talocalcaneal coalition and Naviculocuneiform coalition. This study is focused on the relation between Ankle Joints and the structural change of soft tissues, also finding the most proper angle to obtain good images of Ankle Joint from the patient who wore a plaster on his ankle, when we x-ray with Harris-Beath View($30^{\circ}{\sim}55^{\circ}$) - for observing Subtalar joint, Calcaneus Fracture, Subtentaculum, Tali Fracture and Talocalcaneal coalition. We intend to get the angle which makes us achieve the good image that shows Calcaneus Fracture, Subtentaculum, and Tali Fracture by changing internal angles of the patient's ankle. We evaluated the images obtained from 51 patients with PACS monitor. The result of the evaluation, subtalar joint was not seperated but opened, and Subtentaculum Tali Fracture was seen overlaid. at the angle 30, we could observe Calcaneus Fracture, Subtentaculum Tali Frature and the front part of behind side of subtalar joint well. And Calcaneo Navicularcoalition, Talocal Canealcoalition, Naviculo Cuneiform coalition condition were clearly seen at that angle. At the angle 35, we could achieve the clear images of subtalar comminuted fracture, talus, the behind joint of heel bone and get the high definition image on the degree of talocalcaneal joint separation. In addition to, We could obtain the good wide image of Sinus Tarsi. At the area of 45, We can distinguish the soft tissues from gyps separation. The outer-talus and density of the bone were definitely seen and Calcaneus is more separated than that of at the angle of 35, but this image is distorted. Calcaneus, Subtentaculum Tali show $1.20{\pm}0.414$ at the angle 25, $2.47{\pm}0.516$ at the angle 30, $2.27{\pm}0.458$ at the angle 45. This difference is statistically meaningful. (p<0.05). Including the degree of distortion, The distortion appears less at the area of $30^{\circ}$ but at the area of 40, there is heavy distortion. So, We could get the best image for making a diagnosis. At the $30{\sim}35^{\circ}$ degree for X-raying ankle. and at the $30{\sim}40^{\circ}$ for Calcaneus Fracture, Subtentaculum Tali Fracture.

Fe-based Amorphous Alloy with High Strength and Toughness Synthesized based on nm-scale Phase Separation (nm-수준의 상분리를 이용하여 제조한 고강도 고인성 철계 비정질 합금)

  • Lee, Kwang-Bok;Park, Kyoung-Won;Yi, Sang-Ho;Lee, Jae-Chul
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Experiments have demonstrated that the addition of a moderate amount of V to $Fe_{52}Co_{(20-x)}B_{20}Si_4Nb_4V_x$ amorphous alloy enhances the plasticity of the alloy. In particular, $Fe_{52}Co_{17.5}B_{20}Si_4Nb_4V_{2.5}$ alloy withstood a maximum of 8.3% strain prior to fracture along with a strength exceeding 4.7 GPa. Energy dispersive x-ray spectroscopy conducted on the $Fe_{52}Co_{17.5}B_{20}Si_4Nb_4V_{2.5}$ alloy exhibited evidence of compositional modulation, indicating that nm-scale phase separation had occurred at local regions. In this study, the role played by nm-scale phase separation on the plasticity was investigated in terms of structural disordering and shear localization in order to better understand the structural origin of the enhanced plasticity shown by the developed alloy.

Triple Disruption of the Superior Shoulder Suspensory Complex - Case Report at 5-year-follow up - (상부 견갑 현수 복합체의 3중 붕괴 - 5년 추시 증례 보고 -)

  • Sung, Chang-Meen;Park, Hyung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.143-147
    • /
    • 2012
  • A triple disruption of the SSSC, an extremely rare injury, has been reported by only a few authors. We present a patient who had sustained a triple disruption of the SSSC: coracoid and scapular spine fractures, and an acromioclavicular joint separation. Treatment consisted of an anatomical restoration of the SSSC, with maintenance of the acromiohumeral and coracohumeral distances; this was achieved by open reduction and internal fixation of the fractures and of the separation. Six months after surgery, the injured shoulder was asymptomatic, with full range of motion. Five years after surgery, at the final follow-up, the function of the SSSC had been restored to the patient's complete satisfaction.