• Title/Summary/Keyword: Fracture defect

Search Result 273, Processing Time 0.018 seconds

Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture (안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구)

  • Jeong, Seong Ho;Shin, Seung Han;Park, Seung Ha;Koo, Sang Hwan
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.44-51
    • /
    • 2007
  • Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically. Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.

The Correlation between the Degree of Enophthalmos and the Extent of Fracture in Medial Orbital Wall Fracture Left Untreated for Over Six Months: A Retrospective Analysis of 81 Cases at a Single Institution

  • Sung, Yun Sik;Chung, Chan Min;Hong, In Pyo
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.335-340
    • /
    • 2013
  • Background In patients with medial orbital wall fracture, predicting the correlation between the degree of enophthalmos and the extent of fracture is essential for deciding on surgical treatment. We conducted this retrospective study to identify the correlation between the two parameters. Methods We quantitatively analyzed the correlation between the area of the bone defect and the degree of enophthalmos on computed tomography scans in 81 patients with medial orbital wall fracture who had been left untreated for more than six months. Results There was a significant linear positive correlation between the area of the medial orbital wall fracture and the degree of enophthalmos with a formula of E=0.705A+0.061 (E, the degree of enophthalmos; A, the area of bone defect) (Pearson's correlation coefficient, 0.812) (P<0.05). In addition, that there were no cases in which the degree of enophthalmos was greater than 2 mm when the area of the medial orbital wall fracture was smaller than $1.90cm^2$. Conclusions Our results indicate not only that 2 mm of enophthalmos corresponds to a bone defect area of approximately $2.75cm^2$ in patients with medial orbital wall fracture but also that the degree of enophthalmos could be quantitatively predicted based on the area of the bone defect even more than six months after trauma.

Treatment of Open Calcaneal Fracture with Massive Bone Loss using Femoral Head Allograft and Myocutaneous Free Flap (A Case Report) (종골 외측 1/2 이상의 결손을 동반한 개방성 골절의 동종 대퇴골두 이식과 유리 피판술을 이용한 치료 (1예 보고))

  • Sung, Ki-Sun;Eun, Sang-Soo;Mun, Goo-Hyoun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.111-114
    • /
    • 2007
  • Open calcaneal fracture with more than lateral half of bone loss and soft tissue defect occurred in 17 year-old male patient due to motor vehicle accident. Soft tissue defect included heel pad, peroneal tendon. Bone loss involved mainly most part of inferior tuberosity but not subtalar joint. Open dressing and debridement were done daily in operating room and antibiotics administration was started. After granulation tissue formed, femoral head allograft was performed and fixed with 6.0 mm screws to replace bone defect. Soft tissue defect was covered with latissimus dorsi musculocutaneous free flap. No sign of infection nor major osteolysis was observed in 15 months follow up period. Soft tissue defect was covered with latissimus dorsi musculocutaneous free flap.

  • PDF

Oroantral fistula after a zygomaticomaxillary complex fracture

  • Ahn, Seung Ki;Wee, Syeo Young
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.212-216
    • /
    • 2019
  • Zygomaticomaxillary complex (ZMC) fractures account for a substantial proportion of trauma cases. The most frequent complications of maxillofacial fracture treatment are infections and soft tissue flap dehiscence. Postoperative infections nearly always resolve in response to oral antibiotics and local wound care. However, a significant infection can cause a permanent fistula. A 52-year-old man visited our clinic to treat an oroantral fistula (OAF), which was a late complication of a ZMC fracture. Postoperatively, the oral suture site dehisced, exposing the absorbable plate. However, he did not seek treatment. After 5 years, an OAF formed with a $2.0{\times}2.0cm$ bony defect on the left maxilla. We completely excised the OAF, harvested a piece of corticocancellous bone from the iliac crest, inserted the harvested bone into the defect, and covered the soft tissue defect with a buccal mucosal transposition flap. Although it is necessary to excise OAFs, the failure rate is higher for large OAFs (> 5 mm in diameter) because of the extensive defect in the underlying bone that supports the overlying flap. Inappropriate management of postoperative wounds after a ZMC fracture can lead to disastrous outcomes, as in this case. Therefore, proper postoperative treatment and follow-up are essential.

A Case Study on Configuration Change for Preventing Propulsion Wire Fracture and Structural Deformation of Launch System of UAV (무인기용 발사장비의 추진와이어 파단 및 구조변형 방지를 위한 형상변경 사례)

  • Lim, Dahoon;Park, Gyeong Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.3
    • /
    • pp.533-543
    • /
    • 2022
  • Purpose: The purpose of this study is to identify and resolve the causes of defects in the unmanned aerial vehicle launch system(propulsion wire fracture, rear rail deformation) and to prevent recurrence. Methods: The causes of the two defects were derived through fault tree analysis for each of the two defects and fault reproduction tests. In the case of propulsion wire, the installation of a high speed camera to check the behavior of wire was the driving force behind the defect resolution. Results: The results of this study are as follows; It was determined that the thickness of the washer was less than the maximum tolerance of the pulley was the cause of the propulsion wire fracture defect. Failure to comply with the launch procedure and insufficient safety margin were judged as the cause of the rear rail deformation defect. Accordingly, the configuration was changed to remove each defect. Conclusion: The case of this study was conducted to eliminate defects in the launch system for UAV. The causes of defects were estimated through fault tree analysis. After the configuration change, Structural analysis and launch tests were performed to demonstrate the safety and effectiveness of the modified configuration. As a result, the effect of the modified configuration was verified.

Long-term follow-up of a severely traumatized leg treated with ipsilateral fracture-united fibular transfer in a patient with amputation of the contralateral leg: a case report

  • Kim, Eon Su;Yang, Chae Eun;Kim, Jiye;Kim, Sug Won
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.699-702
    • /
    • 2021
  • Extensive bone loss associated with severe vascular injury remains a challenge for lower extremity reconstruction. The fibular free flap has been utilized for many decades to reconstruct long-segment tibial defects. We present an unusual scenario of unilateral weight-bearing, wherein we salvaged the sole lower extremity by transfer of the fractured ipsilateral fibula and a bipedicled skin flap. A 38-year-old man sustained a severe crush injury in the right leg with loss of circulation. His left lower leg had a soft tissue defect measuring 20×15 cm with an exposed comminuted fracture and a 17-cm tibial defect, along with a segmental fracture of the fibula. Subsequently, we reconstructed the tibial defect by transferring a 17-cm-long section of the ipsilateral fibula. We covered the soft tissue defect with a bipedicled skin flap. The patient eventually began to ambulate independently after surgery.

Reversed Adipofascial Flap for Hindfoot Soft Tissue Defect combined with Open Calcaneal Fracture: A Case Report (개방성 종골 골절과 동반된 후족부 연부조직 결손에서의 역행성 지방근막 피판술: 1예 보고)

  • Ahn, Jae-Hoon;Kang, Jong-Won;Lee, Young-Geun;Choy, Won-Sik
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.105-108
    • /
    • 2006
  • Open calcaneal fractures are potentially devastating hindfoot injuries, in which the status of soft tissue envelope is very important. The reversed adipofascial flap has a merit of simplicity and minimal complication compared to free tissue transfer. We report of a case of open calcaneal fracture with soft tissue defect of hindfoot, which was successfully treated with reversed adipofascial flap.

  • PDF

Ulnar Radial Nonunion Fracture Treated with Recombinant Human Bone Morphogenetic Protein-2 in a Dog (개의 요.척골유합부전의 Recombinant Human Bone Morphogenetic Protein-2 적용 치료례)

  • 홍성혁
    • Journal of Veterinary Clinics
    • /
    • v.18 no.2
    • /
    • pp.156-159
    • /
    • 2001
  • A 6-year-old male mongrel dog with a 7-month history of ulnar-radial nonunion fracture was treated with implantation of recombinant human bone morphogenetic protein-2 (rhBMP-2). The dog had received surgical correction three times prior to the admission but radiography of the affected limb revealed a typical figure of nonunion fracture. Glossly, the fractured ends were sclerotic and the area between the ends was filled with fibrous tissue. After debridement the shaft was fixed by an 10-hole plate. rhBMP-2 at a total dose of 256 micrograms was implanted with a synthetic carrier into the 10-mm defect formed by the debridement. Callus formation responding to rhBMP-2 was radiographically observed at 4 weeks after implantation and the defect bridged both fracture ends by 8 weeks after implantation. The plate was removed at 12 months after implantation. Any complications were not observed for 5 months after removal of the plate.

  • PDF

Acute Shortening and Gradual Lengthening for a Comminuted Tibia Fracture with Massive Bone and Soft Tissue Defect - Case Report - (대량의 골 및 연부조직 결손을 동반한 분쇄 경골 골절에서의 급성 단축술과 점진적 연장술 - 증례 보고 -)

  • Han, Ho-Sung;Huh, Jung-Kyu;Song, Cheol-Ho;Baek, Goo-Hyun;Lee, Young-Ho;Gong, Hyun-Sik
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • Traditional management of comminuted tibia fractures with massive bone and soft tissue defect includes soft tissue coverage and bone grafting. However, this method requires a large flap and a substantial amount of bone graft. Acute shortening can reduce the amount of required soft tissue and bone graft. We report a case of open tibia and fibula fracture with severe bone and soft tissue defect that was successfully treated by acute shortening of the tibia with immediate fibular strut bone graft and then by gradual lengthening of the tibia at its proximal metaphysis.

  • PDF

Effect of Shrinkage Defect on Fracture Impact Energy of A356 Cast Aluminum Alloy (A356 알루미늄 합금의 파단 충격에너지에 대한 수축공결함의 영향)

  • Chul, Hwang-Seong;Kwak, Si-Young
    • Journal of Korea Foundry Society
    • /
    • v.34 no.1
    • /
    • pp.22-26
    • /
    • 2014
  • Internal defects, such as shrinkage during casting, cause stress concentrations and initiate cracking. Therefore, it is important to understand the effects of internal defects on the mechanical properties including the impact behavior. This study evaluates the effects of internal casting defects on the impact performance of A356 Al-alloy castings. The internal shrinkage defects in the casting impact specimen are scanned using an industrial Computed Tomography (CT) scanner, and drop impact tests are performed with varing impact velocities on the A356 casting aluminium specimen ($10mm{\times}10mm$ section area) in order to locate the fracture energy under an impact load. The specimens with defects with a diameter less than 0.35 mm exhibit equivalent fracture impact energies of approximately 32 J and those with a 1.7 mm diameter defect reduced the fracture impact energy by 35%.