• Title/Summary/Keyword: Fracture Resistance

검색결과 935건 처리시간 0.024초

CT시험편의 크기 변화에 따른 파괴저항곡선의 변화 (Variation of the Fracture Resistance Curve with the Change of a Size in the CT Specimen)

  • 석창성;김수용
    • 대한기계학회논문집A
    • /
    • 제24권12호
    • /
    • pp.2963-2971
    • /
    • 2000
  • In order to obtain more realistic fracture resistance curve, research is currently underway to introduce new parameter and to quantify the constraint effect. The objective of this study is to investigate the relationship between the constraint effect of a size(plane size and thickness) and the fracture resistance curve. In this paper fracture toughness tests were performed with various plane size and various thickness of specimens in two materials. The test results showed that the effects of plane size in th4 J-R curve were significant and the curve was risen with an increase in plane size. However, relatively weak influence was observed form the change of the specimen thickness and size. The stress fields near the crack tip of th specimen is close to the HRR field according to increasing the plane size and Q stress appears different value according to material properties and the plane size.

유구치 와동형성이 아말감 파절에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECTS OF CAVITY FORMS ON FRACTURE OF AMALGAM RESTORATION IN DECIDUOUS MOALRS)

  • 하대송;김종관;이종갑
    • 대한소아치과학회지
    • /
    • 제11권1호
    • /
    • pp.159-167
    • /
    • 1984
  • In this experiments, the fracture loads were measured and analysed by using of Instron universal testing machine (Model 1132). With 80 upper and lower deciduous molars that were free of dental caries. Isthmus of teeth were prepared to 1/3 and 1/4 of intercuspal width, and internal line angles with round and sharp shape, and then amalgam restoration were performed. The results of this study were as follows; 1. Resistance to fracture loads were greater with isthmus of 1/3 intercuspal width than of 1/4 intercuspal width, especially, statistically significant difference on upper and lower second deciduous molars. 2. Resistance to fracture loads were greater with rounded internal line angle than sharp internal line angle. The above results were as follows, the fracture loads had greater resistance on isthmus of 1/3 intercuspal width, and rounded internal line angle, but normal physiological occlusal forces could permit isthmus of 1/4 intercuspal width and rounded internal line angle.

  • PDF

Fracture Toughness and Crack Growth Resistance of the Fine Grain Isotropic Graphite

  • Kim, Dae-Jong;Oh, Seung-Jin;Jang, Chang-Heui;Kim, In-Sup;Chi, Se-Hwan
    • Carbon letters
    • /
    • 제7권1호
    • /
    • pp.19-26
    • /
    • 2006
  • Three point bending tests of single edge notched beam (SENB) specimens were carried out to evaluate the fracture behavior of the fine-grain isotropic nuclear grade graphite, IG-11. To measure the crack initiation point and the subsequent crack growth, the direct current potential drop (DCPD) method and a traveling microscope were used. The effects of test variables like initial crack length, specimen thickness, notch type and loading rate on the measured fracture toughness, $K_Q$, were investigated. Based on the test results, the ranges of the test variables to measure the reliable fracture toughness value were proposed. During the crack growth, the rising R-curve behavior was observed in IG-11 graphite when the superficial crack length measured on the specimen surface was used. The increase of crack growth resistance was discussed in terms of crack bridging, crack meandering, crack branching, microcracking and crack deflection, which increase the surface energy and friction force.

  • PDF

Methodology for numerical evaluation of fracture resistance under pinch loading of spent nuclear fuel cladding containing reoriented hydrides

  • Seyeon Kim;Sanghoon Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.1975-1988
    • /
    • 2024
  • It is important to maintain cladding integrity in spent nuclear fuel management. This study proposes a numerical analysis method to evaluate the fracture resistance of irradiated zirconium alloy cladding under pinch load known to cause Mode-III failure. The mechanical behavior and fracture of the cladding under pinch loading can be evaluated by a Ring Compression Test (RCT). To simulate the fracture of hydride precipitates, zirconium matrix, and Zr/hydride interfaces under the stress field generated by RCT, a micro-structure crack propagation simulation method based on Continuum Damage Mechanics (CDM) has been proposed. Our RCT simulation model was constructed from microscopic images of irradiated cladding. In this study, we developed an automated process to generate a pixel-based finite element model by separating the hydride precipitates, zirconium matrix, and interfaces using an image segmentation method. The appropriate element size was selected to ensure the efficiency and accuracy of a crack propagation simulation. The load-displacement curves and strain energies from RCT were compared and analyzed with the simulation results of different element sizes. The finalized RCT simulation model can be used to establish the failure criterion of fuel rods under pinch loading. The advantages and limitations of the proposed method are fully discussed here.

Microdroplet 시험법과 전기저항 측정을 이용한 탄소섬유 강화 Epoxy-AT PEI 복합재료의 수지파괴인성에 따른 잔류응력 및 계면물성 (Interfacial Properties and Residual Stress of Carbon Fiber/Epoxy-AT PEI Composite with Matrix Fracture Toughness using Microdroplet Test and Electrical Resistance Measurements)

  • Kim, Dae-Sik;Kong, Jin-Woo;Park, Joung-Man;Kim, Minyoung;Kim, Wonho;Ahn, Byung-Hyun;Park, In-Seo
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.109-113
    • /
    • 2002
  • Interfacial and electrical properties for the carbon fiber reinforced epoxy-amine terminated (AT) PEI composites were performed using microdroplet test and electrical resistance measurements. As AT PEI content increased, the fracture toughness of epoxy-AT PEI matrix increased, and IFSS was improved due to the improved toughness and energy absorption mechanisms of AT PEI. The microdroplet in the carbon fiber/neat epoxy composite showed brittle microfailure mode. At 15 wt% AT PEI content, ductile microfailure mode appeared because of improved fracture toughness. After curing, the changes of electrical resistance (ΔR) with increasing AT PEI content increased gradually because of thermal shrinkage. The matrix fracture toughness was correlated to IFSS, TEC and electrical resistance. In cyclic strain test, the maximum stress and their slope of the neat epoxy case were higher than those of 15 wt% AT PEI. The results obtained from electrical resistance measurements under curing process and reversible stress and strain were consistent well with matrix toughness properties.

  • PDF

대형배관의 Curved CT 시편을 이용한 파괴저항특성평가에 관한 연구 (A Study on the Evaluation of Fracture Resistance Characteristics of Large Pipe by using the Curved CT Specimen)

  • 김익현;신인환;박건태;홍석우;박승순;윤승현;구재민;석창성
    • 한국정밀공학회지
    • /
    • 제31권7호
    • /
    • pp.623-626
    • /
    • 2014
  • The LBB (Leak Before Break) concept is based on evaluating the fracture toughness. NUREG 1061, Vol.3 announced that the specimen for evaluating fracture resistance needs to have same thickness or thicker than pipe. Therefore, it is difficult to collect specimen from pipe which has same thickness as a pipe. So, ASTM standard suggested the use of standard specimen with 1 inch thickness. However, it has been known that an application of LBB by test results of standard specimen is conservative compare with that by real pipe. In this study, to supplement such conservatism, the evaluation of fracture resistance characteristics was performed with curved CT specimen, which has same thickness and curvature as a pipe. In addition, fracture resistance characteristics of curved CT specimen were compared with those of CT specimen. For this, shape factor F, hpl and g were obtained from FEM analysis using the limit load method.

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

  • Habibzadeh, Sareh;Rajati, Hamid Reza;Hajmiragha, Habib;Esmailzadeh, Shima;Kharazifard, Mohamadjavad
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.170-175
    • /
    • 2017
  • PURPOSE. The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars. MATERIALS AND METHODS. A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (${\alpha}=.05$). RESULTS. Fiber-glass posts with composite cores showed the highest fracture resistance values ($915.70{\pm}323N$), and the zirconia post system showed the lowest resistance ($435.34{\pm}220N$). The corresponding mean value for the Ni-Cr casting post and cores was reported as $780.59{\pm}270N$. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests. CONCLUSION. The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiber-glass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

비원형 단-탄소섬유 보강 시멘트 복합재의 내구성 및 파괴인성 (Durability and Fracture Toughness of Noncircular Type-Carbon Fiber Reinforced Cement Composites)

  • 이영석;김태진
    • 공업화학
    • /
    • 제10권5호
    • /
    • pp.789-795
    • /
    • 1999
  • 본 연구에서는 비원형의 단-탄소섬유를 이용하여 시멘트 복합재를 제조하고 이 복합재의 특성(건조 수축, 동결 융해저항성, 파괴 인성)을 원형 탄소섬유보강 복합재와 비교하여 연구하였다. 그 결과 섬유의 형상과 길이에 크게 의존하였다. C형 탄소섬유보강 시멘트 복합재의 건조수축저감 효과가 다른 형상의 섬유보강 복합재에 비해 우수하였다. 이 효과는 섬유의 종횡비가 클수록 증가하였다. 또한, 동결융해 저항성은 섬유형상의 영향은 두드러지지 않았으나 섬유길이와 섬유함유율에 따라 증가하였다. 특히, C형 보강 시멘트 복합재의 파괴 인성 및 균열 저항성은 다른 것에 비해 크게 개선되었다. 이는 더 큰 계면으로 파괴에너지를 더 많이 흡수하였기 때문으로 생각된다.

  • PDF

콘크리트 파괴특성의 수치해석 (Numerical Analysis of Concrete Fracture Properties)

  • 연정흠
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.237-244
    • /
    • 1995
  • Fracture properties for LEFM, S-FPZ and NS-FPZ models were determined using by finite element method and energy balance from the experimental results of three-point bend tests. For the LEFM model the stress intensity factor needed to increase continuously with crack extension, and for the S-FPZ model the fracture process zone characteristics need to change continuously if the critical stress intensity factor was to remain constant. The LEFM model showed the largest resistance and the slowest crack extension, while the NS-FPZ model showed the smallest resistance and the fastest crack extension. The responses for the S-FPZ model were intermediate between those for the LEFM and NS-FPZ models and the total fracture energy densities for the S-FPZ and NS-FPZ models and the total fracture energy densities for the S-FPZ and NS-FPZ models were equal.

  • PDF

원자로 냉각재배관 엘보우 및 서포트 스컷트용 (Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt)

  • 손종동;임만배
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.