• Title/Summary/Keyword: Fracture Fixation

Search Result 805, Processing Time 0.023 seconds

Dual Plate Fixation for Displaced Transverse Fracture of the Lower Sacrum (전위된 하부 천골 횡골절에 대한 이중 금속판을 이용한 내고정술)

  • Choi, Dong-Hyuk;Park, Ji-Hun;Shim, Seong-Woo;Choi, Yong-Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.178-182
    • /
    • 2020
  • Isolated fractures of lower sacrum are commonly treated conservatively in most cases because of low energy damage and stable fracture. However, surgical treatment is required in displaced unstable fracture. But the surgical technique is not established and even case reports are not common. We reported a case of displaced transverse fracture of the lower sacrum that was treated with an open reduction and dual plate fixation.

Practicability Strength Assessment of a Bone Metallic Plate at the Femur Fixation (대퇴골(Femur)고정용 골 금속판 제작 및 강도 평가)

  • Kim, Jeong-Lae;Ahn, Chang-Sik;Seo, Byoung-Do
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.

Arthroscope-guided Closed Reduction and Internal Fixation of the Lateral Malleolar Fracture (관절경을 이용한 족관절 외과 골절의 비관혈적 정복술 및 내고정술)

  • Shin, Sung-Il;Kim, Gab-Lae;Hyun, Yoon-Suk;Ban, Tae-Seo;Kim, Tae-Hwa
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.74-79
    • /
    • 2008
  • Purpose: In this study, we introduced an newly developed technique of operation for fracture of lateral malleolus of the ankle. We treated the fracture by close reduction and internal fixation using arthroscopy. Materials and Methods: From July 2006 to June 2007, we had treated 23 cases of lateral malleolar fracture (SER type) by closed reduction and internal fixation with arthroscopy and followed them up more six month. Operation time, union time, clinical and functional result were evaluated. Results: After the final follow-up, all the fractures were healed with satisfactory bony union. The subjective result was excellent in 15 cases (65%), good in 8 cases (35%), the objective result was excellent in 13 cases (57%), good in 10 cases (43%), and the roentgenographic result was excellent in 17 cases (74%), good in 6 cases (26%). Conclusion: Closed reduction and internal fixation with arthroscopy technique is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including corrective anatomical reduction and minimizing complication associated with injury of soft tissue.

  • PDF

Isolated Fracture Dislocation of the Tarsal Navicular -A case report- (족부 주상골의 단독 골절 탈구 -증례 보고-)

  • Lee, Young-Kuk;Ahn, Won-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.3 no.1
    • /
    • pp.58-61
    • /
    • 1999
  • Isolated fracture dislocation of the tarsal navicular bone is extremely rare. The mechanism of injury of this fracture dislocation is known as a horizontal or axial load on plantar flexed foot. Closed or open reduction is recommended for displaced navicular fracture. We report one case of isolated fracture dislocation of the tarsal navicular which was treated with closed reduction and percutaneous K-wire fixation.

  • PDF

Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report - (관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 -)

  • Kim, Hyung-Sik;Koh, Il-Hyun;Kim, Sung-Guk;Chun, Yong-Min;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.94-98
    • /
    • 2011
  • Purpose: We present a case of anterior glenoid rim comminuted fracture that was treated with arthroscopic reduction and an AO headless compression screw (HCS) fixation. Materials and Methods: A 31-year old man complained of left shoulder pain after falling down on stairs. The anterior glenoid comminuted fragments were arthroscopically reduced. Fixation with an AO HCS was done after placement of 1.1 mm Kirschner wire as a guide pin through a standard cannulated anterosuperior portal. Results: Twelve months after the operation, union of the fracture was achieved and the range of motion was fully recovered. He did not complain of any discomfort during his activities of daily living. Conclusion: An AO HCS had various screw sizes and this was good for fixation of a small glenoid fracture and a long drill bit and screw driver were useful for fixation of deep seated glenoid fracture. A short guide wire could be replaced by a 1.1 mm K-wire. An AO HCS was useful for fixation of an anterior glenoid rim comminuted fracture.

Treatment of Clavicle Medial End Fracture Using Double-plate Fixation

  • Jang, Seang;Byun, Youngsoo;Yoo, Hyun Seung;Jung, Chul;Shin, Dongju
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.162-166
    • /
    • 2015
  • Clavicle medial end fracture is rare, and it has not been studied extensively. Although there is debate regarding its treatment methods, because of the complications of conservative treatment, surgical treatment has been considered more than conservative treatment. This study describes a surgical method using double-plate fixation for treatment of clavicle medial end fractures in which plates were used on each anterior and superior border according to the anatomical structure of the clavicle. In addition, we report operative results of three patients treated by double-plate fixation.

Acromion Fracture after Hook Plate Fixation for Distal Clavicle Injury: A Report of 2 Cases

  • Kang, Suk;Lee, Ho Min;Back, In Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.168-171
    • /
    • 2016
  • Fractures at the lateral end of the clavicle inevitably require surgical treatment as there is high potential for delayed union or nonunion. Acromioclavicular dislocation also requires stable and solid fixation for healing, and surgical treatment is recommended for the maintenance of joint function. The hook plate maintains the biomechanics of the acromioclavicular joint, enabling early range of motion. Therefore, for the past 10 years, the hook plate has been widely used in distal clavicle fractures and acromioclavicular joint injuries. However, the hook plate is associated with several complications, such as proximal clavicle fractures, widening of the hook hole, rotator cuff tear, subacromial impingement, and often acromial fractures. We report on two unusual cases of acromion fracture after hook plate fixation in patients with distal clavicle fracture and acromioclavicular dislocation alongside a literature review.

PHILOS plate fixation with polymethyl methacrylate cement augmentation of an osteoporotic proximal humerus fracture

  • Kim, Do-Young;Kim, Tae-Yeong;Hwang, Jung-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.156-158
    • /
    • 2020
  • PHILOS plate fixation in osteoporotic proximal humerus fracture of old age is well-known for high complication rate, especially metal failure, providing various augmentation techniques, such as calcium phosphate cement, allogenous or autologous bone graft. We report a case of polymethyl methacrylate augmentation to provide appropriate reduction with a significant mechanical support. This can be a treatment option for displaced unstable osteoporotic proximal humerus fracture with marked bony defect.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

Bone Cement-Augmented Short Segment Fixation with Percutaneous Screws for Thoracolumbar Burst Fractures Accompanied by Severe Osteoporosis

  • Jung, Hyun Jin;Kim, Seok Won;Ju, Chang Il;Kim, Sung Hoon;Kim, Hyen Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.353-358
    • /
    • 2012
  • Objective : The purpose of this study was to determine the efficacy of bone cement-augmented short segment fixation using percutaneous screws for thoracolumbar burst fractures in a background of severe osteoporosis. Methods : Sixteen patients with a single-level thoracolumbar burst fracture (T11-L2) accompanying severe osteoporosis treated from January 2008 to November 2009 were prospectively analyzed. Surgical procedures included postural reduction for 3 days and bone cement augmented percutaneous screw fixation at the fracture level and at adjacent levels without bone fusion. Due to the possibility of implant failure, patients underwent implant removal 12 months after screw fixation. Imaging and clinical findings, including involved vertebral levels, local kyphosis, canal encroachment, and complications were analyzed. Results : Prior to surgery, mean pain score (visual analogue scale) was 8.2 and this decreased to a mean of 2.2 at 12 months after screw fixation. None of the patients complained of pain worsening during the 6 months following implant removal. The percentage of canal compromise at the fractured level improved from a mean of 41.0% to 18.4% at 12 months after surgery. Mean kyphotic angle was improved significantly from $19.8^{\circ}$ before surgery to 7.8 at 12 months after screw fixation. Canal compromise and kyphotic angle improvements were maintained at 6 months after implant removal. No significant neurological deterioration or complications occurred after screw removal in any patient. Conclusion : Bone cement augmented short segment fixation using a percutaneous system can be an alternative to the traditional open technique for the management of selected thoracolumbar burst fractures accompanied by severe osteoporosis.