• Title/Summary/Keyword: Fraction images

Search Result 217, Processing Time 0.028 seconds

GENERATION OF FOREST FRACTION MAP WITH MODIS IMAGES USING ENDMEMBER EXTRACTED FROM HIGH RESOLUTION IMAGE

  • Kim, Tae-Geun;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.468-470
    • /
    • 2007
  • This paper is to present an approach for generating coarse resolution (MODIS data) fraction images of forested region in Korea peninsula using forest type area fraction derived from high resolution data (ASTER data) in regional forest area. A 15-m spatial resolution multi-spectral ASTER image was acquired under clear sky conditions on September 22, 2003 over the forested area near Seoul, Korea and was used to select each end-member that represent a pure reflectance of component of forest such as different forest, bare soil and water. The area fraction of selected each end-member and a 500-m spatial resolution MODIS reflectance product covering study area was applied to a linear mixture inversion model for calculating the fraction image of forest component across the South Korea. We found that the area fraction values of each end-member observed from high resolution image data could be used to separate forest cover in low resolution image data.

  • PDF

Analysis of Vegetation Cover Fraction on Landsat OLI using NDVI (Landsat 8 OLI영상의 NDVI를 이용한 식생피복지수 분석)

  • Choi, Seokkeun;Lee, Soungki;Wang, Baio
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • The Vegetation cover is a significant factor to comprehend characteristics of the ground surface for meterological and hydrological models, which measure energy in the atmosphere or predict the runoff of ground surface. Deardorff introduced vegetation cover fraction to quantitatively comprehend the vegetation cover in 1978. After Deardorff, most of previous researches were conducted on low-resolution or high-resolution images, but only few researches on Landsat that are in medium-resolution images. Therefore, this study aims to investigate a way of calculating the vegetation cover fraction by using NDVI of Landsat images, which were hardly handled previously. For accurate vegetation cover fraction, we compared the evaluated parameters from this study with past vegetation cover fraction parameters that have been calculated for using NDVI of Landsat OLI images. The result of research was shown that NDVI is quite correlated with the vegetation fraction cover in the previous researches. In fact, RMSE of vegetation cover fraction values that obtained through the suggested parameters on this study showed the highest accuracy of 7.3% among all the cases.

Comparison of functional Images obtained by radionuclide angiocardiography and gated blood pool scan (방사성핵종 심혈관조영술의 기능적영상화에 대한 고찰)

  • Bom, Hee-Seung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.186-191
    • /
    • 1991
  • Radionuclide cardiac studies lend themselves exceptionally well to functional imaging. This is especially true for gated blood pool scan (GBP). Making functional images is also possible in radionuclide angiocardiography (RNAC). In this study we tried to validate the functional images obtained from RNAC by comparing it with GBP. Twenty three patients (16 patients with coronary artery diseases, 5 with hypertensive heart diseases, and 2 with nonspecific chest pains) underwent simultaneous RNAC and GBP at the same position (LAO $45^{\circ}$). From both studies, global ejection fraction, regional ejection fraction, phase image, amplitude image, stroke image, paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox images of RNAC are very similar to those of GBP. However, amplitude and stroke images are different. Regional ejection fractions of the left ventricular base, maximum ejection and maximum filling rates obtained from RNAC are significantly different from those of GBP. In conclusion, albeit all of functional images of RNAC is not same as GBP, regional walt motions and global left ventricular function are expected to be successfully analyzed by phase and paradox image and ejection fraction.

  • PDF

Measurement and Evaluation of Scatter Fractions for Digital Radiography with a Beam-Stop Array (Beam-Stop Array를 이용한 DR에서의 Scatter Fraction 측정 및 효용성 평가)

  • Choi, Yu-Na;Cho, Hyo-Min;Kim, Yi-Seul;An, Su-Jung;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Scatter radiation considerably affects radiographic image quality by reducing image contrast and contributing to a non-uniform background. Images containing a large portion of scatter radiation may result in an incorrect diagnosis. In the past few years, many efforts have been made to reduce the effects of scatter radiation on radiographic images. The purpose of this study is to accurately measure scatter fractions and evaluate the effectiveness of beam-stop arrays. To measure scatter fraction accurately, a beam-stop array and the SFC (Scatter Fraction Calculator) program were developed. Images were obtained using the beam-stop array for both an anti-scatter technique with an anti-scatter grid and an air gap technique. The scatter fractions of the images were measured using the SFC program. Scatter fractions obtained with an anti-scatter grid were evaluated and compared to scatter fractions obtained without an anti-scatter grid. Scatter fractions were also quantitatively measured and evaluated with an air gap technique. The effectiveness of the beam-stop array was demonstrated by quantifying scatter fractions under various conditions. The results showed that a beam-stop array and the SFC program can be used to accurately measure scatter fractions in radiographic images and can be applied for both developing scatter correction methods as well as systems.

Spectral Mixture Analysis for Desertification Detection in North-Eastern China

  • Yoon Bo-Yeol;Jung Tae-Woong;Yoo Jae-Wook;Kim Choen
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.419-422
    • /
    • 2004
  • This paper was carried out desertification area change detection from 1980s to 2000s per unit decade using by multitemporal satellite images (Landsat MSS, TM, ETM+). This study aims to use Spectral Mixture Analysis (SMA) to identify and classify study area. Endmembers is selected bare soil, green vegetation (GV), water body using by Minimum Noise Fraction (MNF). Endmembers used to generate increase and decrease images respective from 1980s to 1990s and from 1990s to 2000s. From the analysis of multitemporal change detection for three periods, it was apparent that the area of bare soil increased significantly, with simultaneous decrease of GV and water body. The multitemporal fraction images can be effectively used for change detection. Though there is no field survey dataset, SMA is reliable result of change detection in desertification in China.

  • PDF

Choice of Thresholding Technique in Micro-CT Images of Trabecular Bone Does Not Influence the Prediction of Bone Volume Fraction and Apparent Modulus

  • Kim, Chi-Hyun;Kim, Byung-Gwan;Guo, X. Edward
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.174-177
    • /
    • 2007
  • Trabecular bone can be accurately represented using image-based finite element modeling and analysis of these bone models is widely used to predict their mechanical properties. However, the choice of thresholding technique, a necessary step in converting grayscale images to finite element models which can thus significantly influence the structure of the resulting finite element model, is often overlooked. Therefore, we investigated the effects of thresholding techniques on micro-computed tomography (micro-CT) based finite element models of trabecular bone. Three types of thresholding techniques were applied to micro-CT images of trabecular bone which resulted in three unique finite element models for each specimen. Bone volume fractions and apparent moduli were predicted for each model and compared to experimental results. Our findings suggest that predictions of apparent properties agree well with experimental measurements regardless of the choice of thresholding technique in micro CT images of trabecular bone.

On the origin of post-merger features in galaxy clusters

  • Choi, Hoseung;Yi, Sukyoung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.72.1-72.1
    • /
    • 2012
  • Sheen et al. 2012 reported a high fraction of galaxies with post-merger features in clusters. The fraction is much higher than what analytic calculation predicts based on the fact that subhalos inside galaxy clusters have high relative velocities. In this study, we aim to address the origin of the post-merger features and to draw an implication for the assembly history of the cluster galaxies. We have performed high-resolution hydrodynamic zoom-in simulations on a cluster of ~1015M using the publicly available Adaptive Mesh Refinements (AMR) code, RAMSES. From the simulations, we have constructed mock images of cluster galaxies taking into account age, metallicity, mass of stellar populations and extinction. The mock images enable us to directly compare the simulation result with deep observation data of cluster galaxies. We discuss possible scenarios for the origin of the post-merger features. We also discuss caveats and future perspectives from the study.

  • PDF

Effect of Mixed Jet with Primary Nozzle Area Ratio of Ejector on Oxygen Transfer Characteristics (산소 전달 특성에 미치는 이젝터 구동 노즐 면적비에 따른 혼합 분류의 영향)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.126-133
    • /
    • 2022
  • The objective of this is to experimentally investigate the effect of mixed jet on the oxygen transfer characteristics with the primary nozzle area ratio of an annular nozzle ejector for the application of a microbial fuel cell. A direct visualization method with a high speed camera system was used to capture the horizontal mixed jet images, and a binarization technique was used to analyze the images. The clean water unsteady state technique was used for the oxygen transfer measurement. The air-water mixed jet discharging into a water tank behaved similar to a buoyancy or horizontal jet with the primary nozzle area ratio. It was found that an optimum primary nozzle area ratio was observed where the oxygen transfer performance reached its maximum value due to the decrease of air volume fraction and the increase of jet length and air bubble dispersion.

On the Measurement Technique of Void Fraction by Single Camera Two Phase PIV (단일 카메라 입자영상유속계를 이용한 이상유동 기포율 측정방법)

  • Choi, Dong-Whan;Sung, Jae-Yong;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1558-1563
    • /
    • 2004
  • A measurement technique for the void fraction and the bubble dynamics in gas-liquid two-phase flows has been proposed using a time-resolved two-phase PIV system. For the three-dimensional evaluation of the bubble information, both the images from the front and side views are simultaneously recorded into a high speed CCD camera by reflecting the side image into the front view with the help of a $45^{\circ}$ oriented mirror. Then, a stereo-matching technique is applied to calculate the void fraction, bubble size and shape. To obtain the rising bubble velocities, the 2-frame PTV method was applied. Consequently, the present technique shows good feasibility for the measurements of the volume fractions, mean diameters, aspect ratios and velocities of the bubbles at the three-dimensional point of view.

  • PDF

Differential Molecular Diffusion Effects in $H_{2}-SF_{6}$ Mixture ($H_{2}-SF_{6}$ 혼합 기체 연료에서 분자 차등 확산 효과)

  • Oh, Kwang-Cheul;Choi, Jae-Joon;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.16-25
    • /
    • 2000
  • The differential diffusion of two species in jet is considered. The direct photo images of $H_{2}/SF_{6}$ flame are taken and the non-react jets of $H_{2}/SF_{6}$ mixture are visualized with Rayleigh scattering method. The structures of Dual flame are found in the photography. As the volume fraction of $H_2$ in mixture is increased, the flame at side is long and as the volume fraction of $SF_{6}$ in mixture is increased, the flame at center is long. This phenomena are deduced from the non-react mixture using Rayleigh scattering method. Result show that the volume fraction in the mixture is important in differential diffusion.

  • PDF