• 제목/요약/키워드: Fourier Transform Infrared

검색결과 1,272건 처리시간 0.028초

A Spatial-domain Fourier Transform Infrared Spectrometer: Application for Analyte Measurement in Cell Culture Media

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • 제9권4호
    • /
    • pp.151-156
    • /
    • 2005
  • A spatial-domain Fourier Transform (FT) infrared (IR) spectrometer coupled with a PtSi Schottky­barrier IR detector plane was developed in the spectral range of $2.0-2.5{\mu}m$ for noninvasive measurement of analyte concentrations in cell culture media during cell culture processing. A key optical component of the spectrometer is a Savart plate which is a birefringent polarizer generating coherent two rays for interfering. The spectral resolution of the spectrometer was determined as $71cm^{-1}$ (${\~}0.05{\mu}m$ at $2.5{\mu}m$). Clear IR fringe patterns were imaged on the IR detector plane. The feasibility of the spectrometer for our application was investigated by measuring absorbance spectra of glucose and fetal bovine serum (FBS) which are important compounds in cell culture media. Experiment results show that the spectral quality of glucose and FBS was comparable with the standard spectra acquired with a commercial FT-IR spectrometer, presenting the feasibility of the spectrometer to perform analyte measurement in cell culture media.

COMBUSTION TOXICITY ANALYSIS: ADVANCES USING A SPECIALIZED SAMPLING TECHNIQUE FOR FOURIER TRANSFORM INFRARED (FTIR) ANALYSIS

  • Talandis, Jonas;Innes, J.D.;Cox, A.W.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.178-184
    • /
    • 1997
  • The cone calorimeter as defined by ISO 5660, ASTM 1354, and NFPA 264A is used to assess the reaction to fire of almost any material that must be evaluated in the fire science field. Typical combustion gas analyses include oxygen, CO and CO2. Oxygen consumption is used to determine rate of heat release. Analysis of combustion gases other than oxygen, CO and CO2 has been attempted using filters to remove the solid smoke particles before analysis. This method has generated unreliable results due to the adsorption of many gas components on the active carbon . particles deposited on the filters. A technique using fourier Transform Infrared (FTIB) analysis without filtration will be disclosed and a discussion will be presented of the analytical results of toxic gases produced from various flame retarded polymeric materials. Use of such data in lethal toxic potency determinations is also reviewed.

  • PDF

합성과 고온고압처리 다이아몬드의 감별 연구 (Identification of Synthetic and HTHP treated Diamonds)

  • 송오성;김득중
    • 한국산학기술학회논문지
    • /
    • 제5권5호
    • /
    • pp.395-402
    • /
    • 2004
  • 보석용 다이아몬드의 기술발전에 따라 고온고압법으로 만들어진 합성다이아몬드 인지, 또는 고온고압법(high temperature high pressure:HTHP)으로 향상처리된 천연다이아몬드 인지의 여부를 처리하지 않은 천연다이아몬드와 비교하여 명확히 확인할 필요가 있다. 본 연구에서는 합성다이아몬드를 진동시편자력계를 이용하여 강자성 특성을 보이는 경우 합성다이아몬드로 감별하는데 성공하였다. 또한 HTHP 향상처리 된 TypeIa, TypeIIa 다이아몬드를 FTIR(Fourier Transform Infrared) 분광기를 이용하여 HTHP 처리 공정 전후의 스펙트럼 분석으로 감별할 수 있음을 확인하였다.

  • PDF

Hard Tissue Analysis of NMR after Fluoride Administration

  • Kim, Hye-Young;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.599-602
    • /
    • 2016
  • Fluoride (F) is an important element for the mineralization of body tissues. The purpose of this study was to administer fluoride prenatally to rats to evaluate its beneficial concentration for rat bone using microstructural analysis, to analyze its effect on the bone structure, and to evaluate the effect of its transfer through rat placenta. Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectrometry (NMR) were performed. The $^{19}F$ NMR and $^{31}P$ NMR signals suggested the existence of fluoride ions in the apatite lattice because the signals were caused by the fluoride ions that were coupled to the phosphate atoms and were affected in the phosphate phases other than the element phases in the apatite. Consequently, if it was not affected too much, the desirable concentration of prenatal fluoride treatment could have a helpful effect on the bone crystal structure through placental fluoride transfer.

Removal of Uranium from Aqueous Solution by Alginate Beads

  • Yu, Jing;Wang, Jianlong;Jiang, Yizhou
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.534-540
    • /
    • 2017
  • The adsorption of uranium (VI) by calcium alginate beads was examined by batch experiments. The effects of environmental conditions on U (VI) adsorption were studied, including contact time, pH, initial concentration of U (VI), and temperature. The alginate beads were characterized by using scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Fourier transform infrared spectra indicated that hydroxyl and alkoxy groups are present at the surface of the beads. The experimental results showed that the adsorption of U (VI) by alginate beads was strongly dependent on pH, the adsorption increased at pH 3~7, then decreased at pH 7~9. The adsorption reached equilibrium within 2 minutes. The adsorption kinetics of U (VI) onto alginate beads can be described by a pseudo first-order kinetic model. The adsorption isotherm can be described by the Redlich-Peterson model, and the maximum adsorption capacity was 237.15 mg/g. The sorption process is spontaneous and has an exothermic reaction.

Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques

  • Jabbari, Hamideh Najjarpour;Shabani, Mohammad;Monajjemzadeh, Farnaz
    • 분석과학
    • /
    • 제34권2호
    • /
    • pp.46-55
    • /
    • 2021
  • Evaluation of drug-excipient compatibility is one of the basic steps in the preformulation of pharmaceutical dosage forms. Some reactive excipients have been known so far which may cause stability problems for drug molecules in pharmaceutical dosage forms. The aim of this study was to evaluate drugexcipient compatibility of gliclazide with some common pharmaceutical excipients, known for their ability to incorporate in drug-excipient interactions. Binary mixtures were prepared using lactose, magnesium stearate, polyvinylpyrrolidone, sodium starch glycolate, polyethylene glycol 2000 and dicalcium phosphate. Based on the results; gliclazide was incompatible with all tested excipients; but not with dicalcium phosphate. DSC (Differential Scanning Calorimetry) results were in accordance with HPLC (High Pressure liquid chromatography) data and were more predictive than FTIR (Fourier Transform Infrared Spectroscopy). Drug and reactive excipients incompatibility was fully discussed and documented. It is advisable to avoid incompatible excipients or carefully monitor the drug stability when incorporating such excipients in final formulation designs.

Chemical Reactions in Solid State Complexes of 1,2-Polybutadiene and Palladium Chloride : High Temperature Infrared Study

  • Lee, Joon Y.;Laurence A. Belfiore
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권9호
    • /
    • pp.826-830
    • /
    • 1996
  • Fourier transform infrared (FTIR) temperature studies were performed to examine the microstructural changes that occur in annealing process of the thin films of 1,2-polybutadiene (1,2-PBu)/palladium chloride (PdCl2) complex. The disappearance of the infrared absorption intensities at 1640, 1418, 994 and 910 cm-1 signifies the consumption of 1,2-vinyl groups of 1,2-PBu. The progressive loss of unsaturation and production of methyl groups as a function of temperature were identified by the enhanced infrared absorption intensities at 1447 and 1375 cm-1. The loss of pendent carbon-carbon double bond is considered to involve both palladium-catalyzed addition reaction and thermally induced cyclization.

Thermal denaturation analysis of protein

  • Miyazawa, Mitsuhiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1628-1628
    • /
    • 2001
  • Near infrared (NIR) spectroscopy is a powerful technique for non-destructive analysis that can be obtained in a wide range of environments. Recently, NIR measurements have been utilized as probe for quantitative analysis in agricultural, industrial, and medical sciences. In addition, it is also possible to make practical application on NIR for molecular structural analysis. In this work, Fourier transform near infrared (FT-NIR) measurements were carried out to utilize extensively in the relative amounts of different secondary structures were employed, such as Iysozyme, concanavalin A, silk fibroin and so on. Several broad NIR bands due to the protein absorption were observed between 4000 and $5000\;^{-1}$. In order to obtain more structural information from these featureless bands, second derivative and Fourier-self-deconvolution procedures were performed. Significant band separation was observed near the feature at $4610\;^{-1}$ ,. Particularly the peak intensity at $4525\;^{-1}$ shows a characteristic change with thermal denaturation of fibroin. The structural information can be also obtained by mid-IR and CD spectral. Correlation of NIR spectra with protein structure is discussed.

  • PDF