• Title/Summary/Keyword: Fourier's law

검색결과 33건 처리시간 0.358초

매우 빠르게 움직이는 열원 주위의 온도분포에 관한 연구 (A Study on the temperature Distributions at the Vicinity of a Very Fast Moving Heat Source)

  • 조창주;정우남;이용호
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.162-169
    • /
    • 1999
  • Fourier heat conduction law becomes invalid for the situations involving extremely short time heating, very low temperatures and fast moving heat source(or crack), since the wave nature of heat propagation becomes dominant. For these conditions, the modified heat conduction equation with the finite propagation speed of heat in the medium could be applied to predict heat flux and temperature distributions. In this study, temperature distributions at the vicinity of a very fast moving heat source are investigated numerically. Thermal fields are characterized by thermal Mach numbers(M) defined as the ratio of moving heat source speed to heat propagation speed in the solid. In the transonic and supersonic ranges($M{\ge}1$), thermal shocks are shown, which separate the heat affected zone from the thermally undisturbed zone.

  • PDF

비축대칭 열하중을 받는 원통튜브의 점탄성 응력해석 (Viscoelastic stress analysis of nonaxisymmetrically heated cylindrical tubes)

  • 박진석;서금석;김종인
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.396-403
    • /
    • 1991
  • A solution is presented for the computation of the elastic-creep stresses in a hollow cylinder subjected to nonaxisymmetric temperature distribution. The creep problem is treated by the Maxwell creep model. Laplace transformation is used for reformation of the governing equation of elastic problem and Hooke's law in a function of .gamma. , .theta. , and creep constant. The governing equation is set up using the Airy stress function which leads to the biharmonic equation. The solution is obtained by using Fourer series method and Laplace inverse method used to obtain the stress components which include the variation of time. This solution shows excellent agreement with Lamkin's and Boley & Weiner's solution. The viscoelastic stresses are also obtained for the fuel rob tube subjecting nonaxisymmetric thermal load.

박막에서 쌍곡선형 열전도 방정식에 의한 열전도 해석 (Analysis of Hyperbolic Heat Conduction in a Thin Film)

  • 정우남;이용호;조창주
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.540-545
    • /
    • 1999
  • 고전적인 Fourier 열전도 방정식은 극저온하에서 또는 아주 짧은 시간동안의 가열시 타당성이 없는 것으로 고려되었다. 이러한 조건하에서는 열전도파의 성질이 지배적이기 때문에 , 수정된 Fourier 법칙에 근거한 쌍곡선형 열전도 방정식이 도입되었다. 열전도에 대한 Fourier 모델과 쌍곡선형 열전도모델이 적분변환법과 함께 Green 함수방법을 이용하여 분되었다. 한쪽 표면에서 주기적인 표면가열을 하는 유한한 평판의 열유속 분포 및 온도분포의 해를 제시하였고 각가의 모델로부터 얻어진 결과를 서로 비교검토하였다. 쌍곡선형 열전도 방정식에서 유도된 열전도파는 매개물을 통해 전파되어 맞은편쪽의 단열표면에서 가열 표면쪽으로 반사하였으나 , 고전적인 Fourier 모델에 의한 열은 열적교란이 매개물의 전체에 걸쳐서 전달된 후 즉각적으로 무한한 속도로 열전파가 발생함을 보여주었다.

  • PDF

지하수 model에 관한 모형시험방법 (An Introduction to the Ground Water Model Test)

  • 김주욱
    • 한국농공학회지
    • /
    • 제9권2호
    • /
    • pp.1301-1305
    • /
    • 1967
  • Ground water flow can be studied with model test. Model test of ground water works are necessary for economic and safe design of the works. Also influence of the ground water flow to the durability and safety of hydraulic structures can be studied with this model. a. Sand model ; Water flow through porous media is the principle of sand model. Darcy's formula is the basic equation, $q=k{\frac{dh}{ds}}^{\circ}. The effect of the ground water flow on the grain system itself is represented with this model only. b. Hele-Shaw model ; In this model use is made of the viscous flow analogy. Viscous fluid such as glycerine flowing through two parallel plates depends on Poiseuille law, $q=-c{\frac{dh}{ds}}$. The analogue can be used vertically and horizontally. c. Heat model ; This is based on the analogy of the Fourier's law for heat conduction and Darcy's law for ground water flow. Especially unsteady problem can be studied with this model. A difficulty of the construction of this model is the isolation, which has to prevent losses of the heat. d. Electirc model ; Ohm's law for electric current is analogous to Darcy's law. Resistance material such as metal foil, graphite block, water with salt added, gelatine with salt added, ete. is connected to electric sources and resistor, and equi-voltage line is detected with galvanometer, $N_aCl$, $CuSo_4$, etc. are used as salt in the model. e. Membrane model ; This model is based on the facts that the deflection of a thin membrane obeys Laplace's equation if there is no load in the direction perpendicular to the membrane, and if the dellection is small.

  • PDF

엄밀한 광선추적법에 의한 푸리에변환 holographic kinoform의 분석 (Analysis of Fourier-transform Holographic Kinoforms Using Exact Ray Tracing)

  • 조두진
    • 한국광학회지
    • /
    • 제4권4호
    • /
    • pp.390-396
    • /
    • 1993
  • 1차원 telecentric paraxial holographic kinoform을 푸리에변환 렌즈로 사용하는 경우에 있어서, 3가지 표면양각형태, 즉 평면-볼록면, 블록면-평면, 좌우대칭 불록면에 대하여 스넬의 법칙을 기반으로 하는 엄밀한 광성추적법을 적용하여 분석하였다. kinoform은 F/8, 초점거리 15mm이며 kinoform과 그 주변 매질의 굴절율을 변화시키므로써 zone수와 두께 그리고 포물면의 경사도를 변화시켰다. 일반적으로 좌우대칭 볼록면 형태가 가장 좋은 성능을 갖는 것으로 나타났고, 모든 경우에 있어서 포물면의 경사도가 증가함에 따라 입사각의 증가에 따른 성능이 저하되었다.

  • PDF

저진공 내 시료가열판과 시료의 열전달 (Heat Transfer between Substrate and Substrate-heater in Low Vacuum)

  • 박현재;오수기;신용현;정광화
    • 한국진공학회지
    • /
    • 제17권4호
    • /
    • pp.302-310
    • /
    • 2008
  • 진공 챔버 내부에서 열접촉된 시료가열장치와 시료 사이의 열전달 현상을 고찰하였다. 열전달은 가스 유량과 기체 압력에 따른 대류현상, 시료와 접촉하는 기판가열장치의 표면 거칠기 및 접촉압력에 따른 전도현상, 기판가열장치의 표면 방사율에 따른 복사현상으로 나누어 푸리에 식과 슈테판-볼츠만 식을 이용하여 열흐름 값을 분석하였다. 실험은 시료가열장치의 온도를 $100\;-\;500^{\circ}C$ 사이에서 일정하게 유지하면서 300 mTorr - 1 Torr 사이의 압력에 따른 시료의 온도를 측정하고, 푸리에 식과 슈테판-볼츠만 식을 이용하여 열흐름 값을 계산하였다. 열흐름 값의 산출에 사용된 푸리에 계수의 정확성을 확인하기 위해, 역으로 열흐름 값으로부터 온도차를 구하는 방법을 사용하였으며 0.33 % 오차 내에서 재현됨을 확인하였다.

Fuzzy control for geometrically nonlinear vibration of piezoelectric flexible plates

  • Xu, Yalan;Chen, Jianjun
    • Structural Engineering and Mechanics
    • /
    • 제43권2호
    • /
    • pp.163-177
    • /
    • 2012
  • This paper presents a LMI(linear matrix inequality)-based fuzzy approach of modeling and active vibration control of geometrically nonlinear flexible plates with piezoelectric materials as actuators and sensors. The large-amplitude vibration characteristics and dynamic partial differential equation of a piezoelectric flexible rectangular thin plate structure are obtained by using generalized Fourier series and numerical integral. Takagi-Sugeno (T-S) fuzzy model is employed to approximate the nonlinear structural system, which combines the fuzzy inference rule with the local linear state space model. A robust fuzzy dynamic output feedback control law based on the T-S fuzzy model is designed by the parallel distributed compensation (PDC) technique, and stability analysis and disturbance rejection problems are guaranteed by LMI method. The simulation result shows that the fuzzy dynamic output feedback controller based on a two-rule T-S fuzzy model performs well, and the vibration of plate structure with geometrical nonlinearity is suppressed, which is less complex in computation and can be practically implemented.

1D finite element artificial boundary method for layered half space site response from obliquely incident earthquake

  • Zhao, Mi;Yin, Houquan;Du, Xiuli;Liu, Jingbo;Liang, Lingyu
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.173-194
    • /
    • 2015
  • Site response analysis is an important topic in earthquake engineering. A time-domain numerical method called as one-dimensional (1D) finite element artificial boundary method is proposed to simulate the homogeneous plane elastic wave propagation in a layered half space subjected to the obliquely incident plane body wave. In this method, an exact artificial boundary condition combining the absorbing boundary condition with the inputting boundary condition is developed to model the wave absorption and input effects of the truncated half space under layer system. The spatially two-dimensional (2D) problem consisting of the layer system with the artificial boundary condition is transformed equivalently into a 1D one along the vertical direction according to Snell's law. The resulting 1D problem is solved by the finite element method with a new explicit time integration algorithm. The 1D finite element artificial boundary method is verified by analyzing two engineering sites in time domain and by comparing with the frequency-domain transfer matrix method with fast Fourier transform.

3D thermo-hydro-mechanical coupled discrete beam lattice model of saturated poro-plastic medium

  • Hadzalic, Emina;Ibrahimbegovic, Adnan;Dolarevic, Samir
    • Coupled systems mechanics
    • /
    • 제9권2호
    • /
    • pp.125-145
    • /
    • 2020
  • In this paper, we present a 3D thermo-hydro-mechanical coupled discrete beam lattice model of structure built of the nonisothermal saturated poro-plastic medium subjected to mechanical loads and nonstationary heat transfer conditions. The proposed model is based on Voronoi cell representation of the domain with cohesive links represented as inelastic Timoshenko beam finite elements enhanced with additional kinematics in terms of embedded strong discontinuities in axial and both transverse directions. The enhanced Timoshenko beam finite element is capable of modeling crack formation in mode I, mode II and mode III. Mode I relates to crack opening, mode II relates to in-plane crack sliding, and mode III relates to the out-of-plane shear sliding. The pore fluid flow and heat flow in the proposed model are governed by Darcy's law and Fourier's law for heat conduction, respectively. The pore pressure field and temperature field are approximated with linear tetrahedral finite elements. By exploiting nodal point quadrature rule for numerical integration on tetrahedral finite elements and duality property between Voronoi diagram and Delaunay tetrahedralization, the numerical implementation of the coupling results with additional pore pressure and temperature degrees of freedom placed at each node of a Timoshenko beam finite element. The results of several numerical simulations are presented and discussed.

원판(圓板)의 열판건조(熱板乾燥)에서 컴퓨터 시뮬레이션에 의한 내부온도(內部溫度)와 함수율(含水率) 분포모형(分布模型) (Distribution Model Based on Computer Simulation for Internal Temperature and Moisture Content in Press Drying of Tree Disks)

  • 여환명;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제22권2호
    • /
    • pp.61-70
    • /
    • 1994
  • This study was executed to find the applicability of press drying of tree disk by investigating the shrinkage and drying defect and to form appropriate model by comparing the actual moisture content(MC) and internal temperature in respect of drying time with calculated values based computer simulation to which was applied finite difference method. In press drying disk, heating period, constant drying rate period maintained plateau temperature at 100$^{\circ}C$ and falling drying rate period were significantly distinguished. Actual MC and internal temperature were analogous to those calculated at comparing points. Heat transfer model formed by Fourier's law using specific heat of moist wood and conduction coefficient considering fractional volume of each element of wood cell wall, bound water, free water and air showed applicability as basic data to developing heat expansion, shrinkage and drying stress during press drying. Also mass transfer model formed by Fick's diffusion law using water vapor diffusion coefficient showed applicability. Longitudinal shrinkage was developed by pressure of hot press and tangential shrinkage was restrained by hygrothermal recovery. The heart check, surface check and ring failure were occurred differently in species, but V-shaped crack didn't develop.

  • PDF