• 제목/요약/키워드: Forward inverter

검색결과 56건 처리시간 0.022초

3상 UPS 인버터의 출력전압 왜형률 개선을 위한 고조파 보상기법의 DSP 제어 (DSP Control of Three-Phase UPS Inverter with Output Voltage Harmonic Compensator)

  • 변영복;조기연;박성준;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.269-275
    • /
    • 1997
  • This paper presents real time digital signal processor(DSP) control of UPS system feeding processor(DSP) control of UPS system feeding nonlinear loads to provide sinusoidal inverter output voltage. The control scheme is composed of an rms voltage compensator, the load current harmonics feed-forward loop for the cancellation of output voltage harmonics, and the output voltage harmonics feedback loop for system stability. The controller employs a Texas Instruments TMS320C40GFL50 DSP.

  • PDF

Improved Flux and Torque Estimators of a Direct Torque Controlled Interior PM Machine with Compensations for Dead-time Effects and Forward Voltage Drops

  • Sayeef, Saad;Rahman, M.F.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.438-446
    • /
    • 2009
  • The performance of direct torque controlled (DTC) interior permanent magnet (IPM) machines is poor at low speeds due to a few reasons, namely limited accuracy of stator voltage acquisition and the presence of offset and drift components in the acquired signals. Due to factors such as forward voltage drop across switching devices in the three phase inverter and dead-time of the devices, the voltage across the machine terminals differ from the reference voltage vector used to estimate stator flux and electromagnetic torque. This can lead to instability of the IPM drive during low speed operation. Compensation schemes for forward voltage drops and dead-time are proposed and implemented in real-time control, resulting in improved performance of the space vector modulated DTC IPM drive, especially at low speeds. No additional hardware is required for these compensators.

무수은 면광원 램프용 Scanning Backlight 구동회로 (Scanning Backlight Driver for Mercury Free Flat Fluorescent Lamp)

  • 오은태;정용민;이경인;유호원;이준영
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2009
  • 현재 사용하고 있는 LCD(Liquid Crystal Display) Backlight용 램프는 주로 CCFL(Cold Cathod Fluorescent Lamp)과 EEFL(External Electrode Fluorescent Lamp)이 사용되고 있다. 하지만 이 램프는 수은을 사용하여 RoHS(the Restriction of e use of certain Hazardous Substances in electrical and electronic equipment)규제가 점점 강화되면서 사용이 제한되고 있으며, 이에 따라 수은을 사용하지 않는 램프의 제작이 불가피해지고 있다. 또한 LCD TV는 CRT와 PDP와는 다른 LCD만의 Hold-type 특성과 LC(Liquid Crystal)의 응답속도로 인하여 Motion Blur현상이 나타나는 단점이 있다. 본 논문에서는 RoHS 규제를 만족시키는 무수은 면광원 램프를 구동하기 위한 인버터를 제안한다. 제안한 인버터는 포워드 방식을 사용하여 반도체 소자 및 자기 소자의 수를 줄여서 구동회로가 간단하다. 또한 면광원 램프를 세로방향으로 6블록으로 나누어 스캔구동을 하여 Motion Blur현상을 저감 시켰다. 끝으로 실험을 통하여 제안한 인버터의 유용성을 입증하였다.

도시철도 직류급전용 더블컨버터의 출력특성 향상을 위한 모드 변환 시 점호각 제어 연구 (A Study on the Firing Angle at the Mode Conversion to Improve the Output Characteristics of the Double Converter for Urban Railway DC Power Supply)

  • 서승삼;한성우;변기식
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.533-542
    • /
    • 2015
  • 본 논문은 도시철도 전동차 정차 시에 발생하는 회생전력으로 인해 전차선 가선전압 상승 시에 Converter(Forward)에서 Inverter(Reverse)로 mode 변환하여 상승된 가선전압을 AC 모선으로 환류하여 전차선 전압을 일정하게 유지하고 전동차 정차 시에 발생하는 회생전력을 재사용할 수 있는 부산도시철도의 더블 컨버터 직류 변전설비를 제안하며 전차선 직류전압 품질향상을 위해 부산도시철도 더블 컨버터 직류 변전설비에서 발생하는 Converter/Inverter mode 변환 시의 undershoot와 overshoot를 최소화할 수 있는 최적의 사이리스터 점호각을 시뮬레이션을 통하여 제시하였다.

듀얼 센서를 이용한 무변압기형 태양광 인버터 전류 센서의 오프셋 보정 방법 (Current Sensor Offset Calibration Method using Dual Sensor for trans-less PV Inverter)

  • 홍기남;최익;최주엽;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.182-187
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. Therefore, output current sensor measures sensing value that includes offset again. In this paper we propose new algorithm where two identical forward and reverse sensors are used to calculate the offset in real time. As a result the offset is not correlated with temperature change. The proposed algorithm is verified through PSIM simulation for validity.

  • PDF

차량용 VVVF 인버터 제어시스템 개발 (Development of VVVF Inverter Control System for Propulsion System)

  • 김병섭;이규찬;이학성;김송웅;박영춘;김중한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.249-251
    • /
    • 1994
  • This paper introduces an implementation of high performance voltage source inverter system based on 16bit micro-processor and DSP for the application to modem rolling stock traction system. In contrast with other industry oriented inverter system, this system requires precise control action complying with various load condition and high overload capability. An asynchronous PWM generation and 3' pulse mode technology are adopted in order to improve compliant starting torque characteristics at starting phase and soft backward-forward starting motion.

  • PDF

BLT를 구동하기 위한 초음파 제어기에 관한 연구 (The Research of Ultra Sonic Controller for Operating BLT)

  • 이종규;유태제
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.361-363
    • /
    • 2003
  • The purpose of this research was to discuss the system that operated Ultra sonic transducer of Pelzo electric ceramics type. The structure of controller was made up of digital signal part drive and feedback circuit, and half bridge inverter. Digital signal part was designed to gain the stable oscillation frequency by making consideration of pointed resonance bandwidth. We tried to control inverter by forward feedback condition because BLT based on the flexibility of elements such as temperature and load condition. In addition, transducer was operated as inverter in order to enhance its power efficiency. In this experiment, output voltage waveform and current waveform have been observed by using BLT.

  • PDF

Boost 컨버터와 Forward 컨버터의 조합을 이용한 Cascaded H-bridge 멀티레벨인버터 입력전원의 단일화 (Unification of Input Sources by combination of Boost and Forward converter in Cascaded H-bridge Multilevel Inverter)

  • 권철순;강필순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.455-456
    • /
    • 2011
  • 본 논문에서는 Boost 컨버터와 Forward 컨버터를 조합한 컨버터를 제안한다. 제안하는 컨버터는 시스템 구성상 다수의 독립된 전원을 요구하는 Cascaded H-bridge 멀티레벨인버터와 같은 회로구조에 있어 다수의 독립전원의 확보가 곤란한 경우 단일 입력 전원단으로 시스템을 구성할 수 있는 특징을 가진다. Boost 컨버터의 입력 인덕터는 변압기로 대체되며 컨버터 스위치의 ON 동작시 변압기 일차측 자화인덕턴스에 저장된 에너지가 변압기 이차측과 비절연된 Boost 컨버터의 출력 커패시터로 전달된다. 제안된 컨버터의 동작 모드에 따른 이론적 분석을 시행하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가 (Performance Evaluation of Islanding Detection Method by Phase Shifted Feed-Forward Voltage in Steady-State Grid Condition)

  • 김동욱;김성민
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.373-380
    • /
    • 2018
  • This study proposes a new islanding detection method that uses the phase shift of feed-forward voltage and evaluates the performance of an existing method and the proposed method when the grid frequency changes within the allowable range under steady-state conditions. The investigated existing method, which is slip mode frequency shift (SMS), uses current phase shift to detect islanding. The SMS method supplies reactive current to the grid under this condition, but the proposed method does not generate additional reactive power because it does not depend on the current control loop. The performance in steady-state grid condition is evaluated through simulations and experiments.

Research on the Mechanism of Neutral-point Voltage Fluctuation and Capacitor Voltage Balancing Control Strategy of Three-phase Three-level T-type Inverter

  • Yan, Gangui;Duan, Shuangming;Zhao, Shujian;Li, Gen;Wu, Wei;Li, Hongbo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2227-2236
    • /
    • 2017
  • In order to solve the neutral-point voltage fluctuation problem of three-phase three-level T-type inverters (TPTLTIs), the unbalance characteristics of capacitor voltages under different switching states and the mechanism of neutral-point voltage fluctuation are revealed. Based on the mathematical model of a TPTLTI, a feed-forward voltage balancing control strategy of DC-link capacitor voltages error is proposed. The strategy generates a DC bias voltage using a capacitor voltage loop with a proportional integral (PI) controller. The proposed strategy can suppress the neutral-point voltage fluctuation effectively and improve the quality of output currents. The correctness of the theoretical analysis is verified through simulations. An experimental prototype of a TPTLTI based on Digital Signal Processor (DSP) is built. The feasibility and effectiveness of the proposed strategy is verified through experiment. The results from simulations and experiment match very well.