• Title/Summary/Keyword: Foreign patient

Search Result 358, Processing Time 0.024 seconds

Readability of Printed Educational Materials Used to Inform Computer Tomography (환자/보호자 교육 및 건강정보제공용 인쇄매체의 읽기쉬움 평가 연구)

  • Yoo, Hye-Ra
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.3
    • /
    • pp.670-679
    • /
    • 2001
  • This study examined the readability of 4 different kinds of patient education handouts about computer tomography tests from 5 different university-affiliated hospitals in Korea. Readability was evaluated in terms of syntax. length of sentence, usage of unfamiliar words. foreign words. Chinese words, abbreviation, and technical jargon. This study found that all of the handouts were very difficult to read. An excessive use of complex and long sentences was found. Unfamiliar words, rarely used in everyday life, were recklessly used. Most of the unfamiliar words were Chinese words and can be exchanged with Korean language. Excessive medical terminologies were used without any explanations. Based on the study results, guidelines to make the handouts easier and more accessible to patients and their family were recommended.

  • PDF

Leaflet Fracture and Embolization of a CarboMedics Prosthetic Mitral Valve: Case Report

  • Kim, Tae Yeon;Kim, Myoung Young
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.419-421
    • /
    • 2021
  • Fracture of prosthetic valve leaflets in the absence of traumatic injury is very rare. Leaflet fracture can cause acute pulmonary edema and cardiogenic shock and is potentially life-threatening, requiring emergency surgery. Thus, a leaflet fracture must be diagnosed quickly and accurately. We present the case of a 46-year-old man with CarboMedics prosthetic aortic and mitral valve replacements implanted 24 years previously. The patient presented at our emergency department with abrupt dyspnea and fever. We diagnosed severe mitral valve regurgitation with anterior leaflet fracture. The patient underwent venoarterial extracorporeal membrane oxygenation and delayed mitral valve replacement. The foreign body was removed step by step because the diagnosis was missed. Two pieces of broken leaflets were found in the left common iliac artery and left external iliac artery. The patient was treated successfully and remains asymptomatic 1 year following surgery.

Fractured needle as an unusual complication of the lingual nerve block: a case report

  • Erdil, Aras;Demirsoy, Mustafa Sami;Colak, Sefa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.4
    • /
    • pp.315-321
    • /
    • 2022
  • Although rare, hypodermic needle fractures can occur in the maxillofacial region. In cases of fracture, urgent intervention is required to prevent further complications. We present the case of a 37-year-old female patient with a fractured needle in the left sublingual fossa during a lingual nerve block 6 months before referral. The fragment of a 30-gauge needle was located using cone-beam computed tomography and retrieved under local anesthesia with blunt dissection. The patient recovered uneventfully, except for predictable postoperative inflammatory complications, which resolved within 2 weeks. Precautions should be implemented to prevent needle fractures, which are usually preventable. However, if the retrieval is unsuccessful, the patient should be referred to a well-equipped surgical unit without delay.

A Foreign Body Found in the Pulmonary Artery of a Traffic Accident Victim with a Chest Injury and Near-amputation of the Upper Extremity - A case report - (흉부 손상과 함께 우상지에 절단에 가까운 열창을 입은 교통 사고 환자에서 발견된 폐동맥 내 이물질 - 1예 보고 -)

  • Choi, Goang-Min;Kim, Heung-Cheol;Cho, Kwang-Yun;Kim, Hyung-Soo
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.536-539
    • /
    • 2008
  • We present a case with a foreign body in the left pulmonary artery, found in a traffic accident victim. A 52-year-old woman sitting in the passenger side of a car had massive bleeding and near complete amputation of her right forearm in addition to multiple rib fractures and a hemopneumothorax. At arrival to the emergency room, the patient had signs of shock; she was anemic, drowsy and hypotensive. A large volume of blood and crystalloid fluids were administered via the left subclavian vein with a rapid infusion device (Level $1^{(R)}$). As the lung contusion improved, a foreign body was noticed in the left lung field on plain x-rays. Pulmonary angiography was performed and revealed a 15 cm foreign body in the left basal segment of the common pulmonary artery. The foreign body was successfully retrieved using vascular forceps via the percutaneous femoral vein approach.

Surgical Removal of the Lung Lobe Metal Foreign Body in a Dog

  • Hwang, Yawon;Kang, Jihoun;Chang, Dongwoo;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.108-111
    • /
    • 2017
  • A 4-year-old, weighing 7.6 kg, castrated male, Pug presented with ingestion of gastric cavity foreign body. Physical examination revealed panting, retching and hyper-salivation. Blood chemistry and complete blood cell count were normal, but hypophosphatemia was observed. An abdominal radiograph revealed the foreign body (FB), round shape and 2 cm length, at the pyloric region of stomach. A thoracic radiograph revealed an incidental metal FB, 3.5 cm length, at the cranial portion of the diaphragm. An upper gastrointestinal endoscopy was performed to remove the FB in the stomach and then a peach-pit was removed. However the metal FB was not found in the esophagus therefore a lateral thoracotomy was performed. A right lateral thoracotomy through the $7^{th}$ intercostal space was accomplished to expose the right caudal lung lobe. After open the thoracic cavity, foreign body was not observed by gross evaluation and caudal lung lobe was attached to the diaphragm. The FB was identified inside the lung lobe and surrounded by granulation tissue. The metal FB (sewing needle) was removed with blunt dissection and incised lung lobe was sutured using absorbable suture material PDS 4-0 with interrupted suture. A thoracotomy tube was inserted into the thoracic cavity during surgery. Patient's respiration became stable after surgery. A chest tube was removed 3 days after surgery. No complications were noted and the dog was discharged 4 days after surgery. In small animal, foreign body ingestion is a common reason for emergency. After ingestion of the FB, perforation through the esophagus and migration to inside the lung lobe is not common in small animals. In this case, thoracic metal FB was identified incidentally and removal of a thoracic FB with thoracotomy was performed successfully.

Percutaneous Transhepatic Removal of Migrated Biliary Stent from a Chronic Biloma Cavity (만성 담즙종 공동 내로 이동한 담도 스텐트의 경피경간적 제거)

  • Hyoung Nam Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.442-447
    • /
    • 2020
  • Iatrogenic foreign bodies are a challenging complication to both the interventional radiologist and patient, resulting in impaired quality of life and substantial financial cost. The case report describes a successful percutaneous transhepatic removal of an intra-abdominal foreign body. A 72-year-old man underwent surgery for placement of a retrievable covered stent for refractory bile leakage after left hemihepatectomy. Three days after placement, stent folding and migration into a chronic biloma cavity occurred via the bile leakage site. By using a balloon catheter technique, the folded stent could be straightened and repositioned into the bile duct to minimize stent-strut injury during retrieval. The interventional approach could be a valid treatment option for intra-abdominal foreign bodies, as well as intravascular foreign bodies. A thorough understanding of devices and techniques can provide the interventional radiologist with valuable information regarding procedural planning and the management of iatrogenic foreign bodies.

Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Life-threatening nasotracheal tube obstruction by a blood clot: a case report

  • Dajeong Lee;Chan Yong Park;Sang Wha Kim
    • Journal of Trauma and Injury
    • /
    • v.37 no.3
    • /
    • pp.220-223
    • /
    • 2024
  • The nasotracheal tube (NTT) is frequently used in oral and maxillofacial surgery and is generally considered a safe means of protecting the airway while ensuring an adequate surgical field. The most common complication associated with NTT is epistaxis, and only a few cases of foreign body obstruction have been reported. In this case report, the authors aimed to highlight the potential for NTT obstruction following surgery. A 24-year-old female patient, who underwent mandibuloplasty and rhinoplasty at a local clinic, was referred to our hospital patient due to dyspnea and edema on her right mandibular angle. Even with NTT, patient continued to experience mild dyspnea and tachypnea, so a T-piece was applied. However, tachycardia accompanied by a sudden worsening of dyspnea was observed, and bag-valve-mask ventilation was initiated promptly. But oxygen saturation remained unimproved, so an emergency cricothyroidotomy was performed. After 4 hours, the patient's condition stabilized. Upon examination, the previously inserted NTT was identified, and a blood clot approximately 10 cm long at the NTT tip was discovered, causing lumen obstruction. The obstructions of NTT can lead to serious or life-threatening consequences if left unobserved or ignored. Therefore, when a patient with an NTT complains of dyspnea, clinicians should promptly investigate the possibility of partial NTT obstruction to ensure the airway's security.

Penetrating chest trauma from a "less lethal" bean bag in the United States: a case report

  • Gloria Sanin;Gabriel Cambronero;Megan E. Lundy;William T. Terzian;Martin D. Avery;Samuel P. Carmichael II;Maggie Bosley
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.421-424
    • /
    • 2023
  • This case report presents the case of a 49-year-old man who presented to our level I trauma center after sustaining injuries in an altercation with local law enforcement in which he was shot with a less lethal bean bag and tased. In a primary survey, a penetrating left supraclavicular wound was noted in addition to a taser dart lodged in his flank. No other traumatic findings were noted in a secondary survey. Given hemodynamic stability, completion imaging was obtained, revealing a foreign body in the left lung, a left open clavicle fracture, a C5 tubercle fracture, a possible grade I left vertebral injury, and a left first rib fracture. Soft tissue gas was seen around the left subclavian and axillary arteries, although no definitive arterial injury was identified. The bean bag projectile was embedded in the parenchyma of the left lung on cross-sectional imaging. The patient underwent thoracotomy for removal of the projectile and hemostasis. A thoracotomy was chosen as the operative approach due to concerns about significant bleeding upon foreign body removal. A chest tube was placed and subsequently removed on postoperative day 5. The patient was discharged on postoperative day 7. At a 2-week outpatient follow-up visit, the patient was doing well. This case report is the first to describe this outcome for a drag-stabilized bean bag. Although law enforcement officers utilize bean bag projectiles as a "less lethal" means of crowd control and protection, these ballistics pose significant risk and can result in serious injury.

A statistical study of the foreign bodies in the food and air passages (식도 및 기도이물의 통계적 고찰)

  • 박근목;우영태;김은우;박해수
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.9.2-9
    • /
    • 1977
  • A Statistical study was carried out on 64 cases of the foreign bodies in the food and air passages, who visited the Dept. of Otolaryng. of Korea General Hospital from Jan. 1971 to Dec. 1976. The following results were obtained. 1. The total number of foreign bodies were 64 cases, which is approximately 0.69% of the total number of new patients who visited the out patient department during the same period. Among them 55 cases were foreign bodies in the food passage and 9 cases were foreign bodies in the air passage. The ratio between the food and air passages was about 6.1 : 1. 2. The frequently encountered foreign bodies in the esophagus were coin, bone, meat and food particle in order. Bean and peanut were male and 31 case the most frequent foreign bodies in the air passage. 3. In sex distribution, 33 cases were male and 31 cases were female, and the ratio between male was 1.1:1. 4. In the age distribution, 35 cases (54.7%) of all foreign bodies were under 5-year-old, especially coin was 96.2%. 5. The most prevalent site of lodgement in the food passage was the 1st esophageal narrowing, which corresponds to 69.1%. 6. In duration of lodgement, 38 cases (69.1%) of foreign bodies in the food passage were removed within 24 hours, and the longest duration was 90 days. 7. Almost all of the foreign bodies in the food and air passages were removed under local or no anesthesia by esophagoscopy, laryngoscopy.

  • PDF