• Title/Summary/Keyword: Forced drainage

Search Result 25, Processing Time 0.016 seconds

Heat Exchange Drainage Method Induced Bearing Capacity Characteristic (열유도 배수공법이 적용된 지반의 하중지지 특성)

  • Shin, Seung-min;Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.159-164
    • /
    • 2017
  • This paper presents the results of an investigation into the thermo-hydromechanical response of weathered granite soil. The effect of forced change temperature and relative humidity at the soil layer boundaries were monitored during heating. A series of load settlement test were performed on layers of compacted, unsatureated weathered granite soil with geosynthetic embedded at mid height before and after application of heat exchanger to the base of the soil layers. The results from this study indicated the potential for using embedded heat exchangers for the mechanical improvement of geotechnical systems incorporating weathered granite soil.

Water Quality Model Development for Loading Estimates from Paddy Field (논에서의 오염부하 예측을 위한 범용모형 개발)

  • Jeon, Ji-Hong;Hwang, Ha-Sun;Yoon, Kwang-Sik;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.344-355
    • /
    • 2003
  • Water quality model applicable paddy field was developed using field experiment during 1999 ${\sim}$ 2002. This model involves inputs from fertilization and sediment release as dirac delta function and continuous source function, respectively, and can simulate various processes such as ponded depth, surface drainage, total nitrogen concentration and total phosphorus concentration in a daily basis. The model was calibrated using data collected from field experiments which was irrigated with ground water and validated from field experiments which was irrigated with surface water. The nutrient concentration of surface water depended on the fertilization and dirac delta function can efficiently explain the valiance of nutrient concentration of surface water by fertilizer. As a result of calibration and validation, this model demonstrates good agreement. The model fit efficiencies ($R^2$) of ponded depth, surface concentration of TN and TP were 0.93,0.98 and 0.95, respectively for calibration, and those of TN and TP were 0.99 and 0.70, respectively for validation. We can apply lake and reservoir model to analysis paddy field considered with shallow ponded system, but it will need so many parameters and have much uncertainty. Fortunately, paddy field have a series of cultural practices yearly basis, such as irrigation-fertilization-forced drain-harvest with a similar time , so simple model may explain the mechanism for paddy field. Water quality model for paddy field developed in this study is simply, needs little parameters, but appeared high applicability to evaluate paddy filed drainage. We recommend this model to estimate nutrient loading from paddy field and establish best management practice.

Effects of a Forced Air-Flow System for Recovery of Turfgrass after Intensive Traffic Injury (집중적 답압 피해에서의 잔디 회복을 위한 강제 흡.호기 순환식 설비의 효과)

  • Lee, Jeong-Ho;Son, Jin-Su;Kim, In-Chul;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.21 no.2
    • /
    • pp.127-135
    • /
    • 2007
  • Korea and Japan hosted the FIFA World Cup Soccer Game in 2002. Ten stadiums had been built and more than 30 soccer grounds for practice were renovated in Korea. Sport fields in both countries had problems on cool-season turfgrass growth and quality by summer decline during humid and warm climate especially followed by intensive uses. We measured the effects of air-flow system, which is designed to optimize rootzone soil gas and moisture levels to promote the growth and maintenance turfgrass. This experiment was carried out to verify the effects of the system on soil gas exchange, ground resilience, and turfgrass recovery in turfgrass rootzone. Within 1 or 2hr of operation of the system, rootzone soil gas ($CO_2$, $O_2$) levels returned to natural atmospheric levels completely Soil $CO_2$ levels began to decrease within the first 10 min of operation of the system. The levels were reduced from 1.3 to 0.06% after 30 min, and natural atmospheric levels within 1 hr. When the system was turned off, $CO_2$ levels increased to 0.36% and 0.7% after 5 and 20 hr, respectively. The application of the system did not affect the resilience of turf surface after traffic treatments. Higher traffic treatment resulted in higher surface resilience especially in zoysiagrass plots. Operation of the system had a significant beneficial impact on turf recovery by increased root dry wight and improved turf quality, as compared with the non-operated check plots.

The Research of Storage Capacity & Sedimentation of Reservoirs in HONAM Province (호남지방에 저수지의 매몰상황과 저수량에 관한 조사연구(농학계))

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.2
    • /
    • pp.2262-2275
    • /
    • 1971
  • Fourteenes rervoirs maintained by the local land improvement associations in the province of Chullabuk-Do and 20 reservoir maintained by thos in the province of Chullanam-Do, were surveyed in connection with a correction between storage capacity and sediment deposit. In addition to this survey, 3,347 of small reservoir, that lie scattered around in the above-mentioned two provinces were investigated by using existing two provinces were investigated by using existing records pertaining to storage capacity in the office of City and country, respectively. According to this investigation the following comclusions are derived. 1. A sediment deposition rate is high, being about $10.63m^3/ha$ of drainage area, and resulting in the average decreasc of storage capaity by 27.5%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of trees. Easpecially, in small reservoir, an original average design storage depth of 197mm in irrigation water depth is decreased to about 140mm. 2. An average unit storage depth of 325.6mm as the time of initial construction is decreased to 226mm at present. This phenomena causes a greater shortage irrigation water, since it was assumed that original storage quantity was already in short. 3. Generally speaking, seepage rates through dam abutment intakepipe, etc, are high due to insufficient maintenance and management of reservoir. 4. It is recommended that sediment deposit should be dredged when a reservoir is dry in drought. 5. Farmers usually waste excessive irrigation water. 6. Water saving methods should be practiced by applying only necessary water for growing stage of rice. 7. In are as where water defficiency for irrigation is severe, a soil moisture content should be kept at about 70% by applying water once in several days. 8. Tube wells should be provided so as to exploit ground water and subsurface current below stream bed as much as possible. 9. If an intake weir was constructed, a water collection well should be built for the use in drought. 10. Water conservation should be forced by converting devastated forests contained in the drainage area of reservoir to protected forests so as to take priority of yrefor estation, gully control, the prohibition of disorderly cutting of trees, etc. 11. Collective rice nurseries should be adopted, and it should be recommended that irrigation water for rice nurseries is supplied by farmer themselves. 12. Sediment desposit in reservoir should be thoroughly dreged so as to secure a original design storage capacity. 13. The structure of overflow weir should be automatic so as to freely control flood level and not to increase dam height.

  • PDF

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF