• Title/Summary/Keyword: Force transducer

Search Result 167, Processing Time 0.028 seconds

Attenuation Characteristics of AE/MA Waves in Charcoal Granite (차콜 화강암에서의 AE/MA파의 감쇄특성)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.3
    • /
    • pp.131-136
    • /
    • 1996
  • Attenuation characteristics of AF/MA motions which involve high frequencies were investigated through pencil-lead fracture tests on a fine-grained granite specimen. For the study, calibrated six transducers were employed to detect the signals and the pencil-lead was fractured as a step unloading force to generate AE/MA signals. The arnplitude AE/MA waves is affected by the relative orientation of source and transducer as well as the source distance. The attenuation constant for Charcoal granite is obtained as 1.058 which could be applied for a given ray-path regardless of the relative orientation of source and transducer.

  • PDF

A Development of an Insole Type Local Shear Measurement Transducer and Measurements of Local Plantar Shear Force During Gait (인솔형 국부 전단센서의 개발 및 보행 시 발바닥의 국부 전단력 측정)

  • Jeong Im Sook;Ahn Seung Chan;Yi Jin Bok;Kim Han Sung;Kim Young Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.213-221
    • /
    • 2005
  • An insole type local shear force measurement system was developed and local shear stresses in the foot were measured during level walking. The shear force transducer based on the magneto-resistive principle, was a rigid 3-layer circular disc. Sensor calibrations with a specially designed calibration device showed that it provided relatively linear sensor outputs. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Sensor outputs were amplified, decorded in the bluetooth transmission part and then transferred to PC. In order to evaluate the developed system, both shear and plantar pressure measurements, synchronized with the three-dimensional motion analysis system, were performed on twelve young healthy male subjects, walking at their comfortable speeds. The maximum peak pressure during gait was 5.00kPa/B.W at the heel. The time when large local shear stresses were acted correlated well with the time of fast COP movements. The anteroposterior shear was dominant near the COP trajectory, but the mediolateral shear was noted away from the COP trajectory. The vector sum of shear stresses revealed a strong correlation with COP movement velocity. The present study will be helpful to select the material and to design of foot orthoses and orthopedic shoes for diabetic neuropathy or Hansen disease.

A Development of Device for Measurement of Vertical Ground Reaction Force(II) (수직 반작용력 측정 장치 개발(II))

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.341-354
    • /
    • 2003
  • The purpose of this study was to develop the uniaxial force plate system which is measured by the vertical force. The VGRF(vertical ground reaction force) 1.0 was composed of 2 bath digital scales, 2 indicaters, and analyzing software. This system was newly renovated to VGRF 2,0 which are 2 industrial digital scales, 2 adjustable indicators, and enforced analyzing software. Changes of the new system were as follows. First, the height of the plate was 75% lower than before. Second, sensing ability of the load cell was changed from 90 - 0.05kg to 300 - 0.1kg. Third, the speed of data processing was changed from 17 per second to 60 per second. Fourth, analyzing software was enforced to develop and calculate the data. For the test of the system, two different types(bare foot, high-heeled shoes) gait was adopted. highly skilled female walker(23yrs, height 165cm, body mass 46.8kg) participated for the experimental study. During the dynamic performance(gait analysis), the data of each load cell were very similar to the previous studies. Specifically, bare foot walking had less vertical force than high-heeled shoes. Consequently, VGRF 2.0 can sense the general dynamic movements as well as static load conditions.

A Study on Selection of Ultrasonic Transducer and Contact Material for Surface Irregularities of Stone Cultural Heritage (석조문화유산의 표면 요철도에 적합한 초음파 탐촉자 및 접촉매질 선정 연구)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.267-278
    • /
    • 2015
  • In this study, the elastomer cover, a new contact material, was developed to establish the customized ultrasonic measurement considering surface irregularities of stone cultural heritages. The cover exhibits high elastic force and wear resistance because it has tensile strength of 17MPa and elongation of 625%. In addition, as a result of comparative experiments for the seven types according to transducers and contact materials including the elastomer cover, rock surface irregularities significantly affect attenuation of ultrasonic velocity. The phenomenon was more noticeable in the chiseling finish and indirect transmission measurement rather than the dabbed finish and direct transmission measurement. However, the Type F using the exponential transducer and elastomer cover showed stable P-wave velocity and high amplitude regardless of the surface irregularities. This because the elastomer cover sufficiently sticks to surface irregularities and removes pores between a transducer and a rock specimen. Therefore, the Type F should be used for the ultrasonic measurement of stone cultural heritages with surface irregularities.

Hydraulic Force and Impeller Evaluation of a Centrifugal Heart Pump

  • Timms, D.L;Tan, A.C.C;Pearcy, M-J;Mcneil, K;Galbraith, A
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.376-381
    • /
    • 2004
  • A rig was constructed to test the performance characteristics and compare the hydraulic forces exerted on a centrifugal type artificial heart impeller. A conventional shaft. seal and bearing system. while driven by a small electric motor. supported the impeller which was separated from the pump casing by a six degree of freedom force transducer (JR3 Ine). Radial (x. y) and axial (z) hydraulic forces were recorded and compared. At physiological operating conditions. the results indicate that the double entry/exit centrifugal pump encounters a smaller radial force and significantly reduced axial thrust. These experimental results are valuable in the design of a magnetic bearing system to suspend the impeller of a centrifugal artificial heart pump. This experimental technique may also be applied to evaluate the required capacity and predict the lifetime of contact bearings in marine pumps.

A High power and Precision Ultrasonic Linear Motor with Multi-support Mechanism (다점 지지 고출력 고정도 초음파 모터)

  • Lee S.K.;Yun C.H.;Lee J.Y.;Cha H.R.;Kim W.K.;Kang J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.151-152
    • /
    • 2006
  • Nowadays, great attention has been shown to the question of ultrasonic linear motor for accomplishing the high positioning accuracy and high driving force in the semiconductor and optical industry. Ultrasonic linear motors have many advantages such as simple structure, quick response, ability to maintain position without energy consumption, and electromagnetic effect. And BLT has attracted attention to accomplish large vibration amplitude and large mechanical force. Authors designed and developed the new type of ultra sonic linear motor with multi support mechanism, achieved 75N of output force and 0.45m/s of velocity.

  • PDF

EMG-based Prediction of Muscle Forces (근전도에 기반한 근력 추정)

  • 추준욱;홍정화;김신기;문무성;이진희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1062-1065
    • /
    • 2002
  • We have evaluated the ability of a time-delayed artificial neural network (TDANN) to predict muscle forces using only eletromyographic(EMG) signals. To achieve this goal, tendon forces and EMG signals were measured simultaneously in the gastrocnemius muscle of a dog while walking on a motor-driven treadmill. Direct measurements of tendon forces were performed using an implantable force transducer and EMG signals were recorded using surface electrodes. Under dynamic conditions, the relationship between muscle force and EMG signal is nonlinear and time-dependent. Thus, we adopted EMG amplitude estimation with adaptive smoothing window length. This approach improved the prediction ability of muscle force in the TDANN training. The experimental results indicated that dynamic tendon forces from EMG signals could be predicted using the TDANN, in vivo.

  • PDF

Response Characteristics of the PZT Transducers during Glass Capillary Breakage (유리모세관 파괴시 방출된 탄성파에 대한 PZT 변환기의 응답특성)

  • Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.1
    • /
    • pp.33-41
    • /
    • 1998
  • The response characteristics of the PZT transducers during glass capillary breakage were studied at the epicenter of the glass plate. The PZT transducers had been made by using EC-65 PZT ceramics(supplied by Edo co.) with a constant area and a various thickness. The theoretical displacement and velocity at the epicenter of glass plate with an air boundary condition were calculated by assuming the point load of 1N force strength and a rise time of 280 ns with a ramped functional dependence, and the 1st pulses of the PZT transducer may be considered as the vertical velocity incident on the electrode of the PZT ceramic. The responses of the PZT transducer may be depended on the thickness mode of the PZT ceramic below 0.33 in the ratio of the thickness to the diameter of PZT ceramic, but the reponse of the PZT transducer may be depended on the other modes of PZT transducer in the addition of the thickness mode of the PZT ceramic above 0.33. The full time of half maximum at the 1st pulse was nearly 280 ns without a variation of applied breakage load and the resonant frequency of the PZT transducer, and then may be considered as the rise time of a AE source. The maximum amplitude of the 1st pulse depended on the incident vertical velocity and capacitance of the PZT transducer. Therefore, the full time of half maximum and maximum amplitude of the 1st pulse may be considered as the rise time and strength of acoustic emission source respectively.

  • PDF

Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices (중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정)

  • Lee, Myoung-Won;Seong, Ki-Woong;Lim, Hyung-Gyu;Kim, Min-Woo;Jung, Eui-Sung;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Lee, Sang-Heun;Lee, Kyu-Yup;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.

고강도 알루미늄 합금 A7075-T6의 마찰용접성에 관한 연구

  • 강성보
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.71-75
    • /
    • 1998
  • This study deals with the friction weldability of A7075-T6 having high specific strength. The friction welding conditions used are rotation speed 2000rpm, friction pressure 40MPa, friction time 1.5sec, upset pressure 40~100MPa, upset time 5sec. First, upset length was measured by displacement transducer. The plastic flow in 7075-T6 weld generates convex lens shaped resion by friction and concave lens shaped resion by axial force. Under the condition of upset pressure 85MPa, the friction welds have tensile strength of 552MPa and shear strength of 262MPa.

  • PDF