DOI QR코드

DOI QR Code

A Development of Device for Measurement of Vertical Ground Reaction Force(II)

수직 반작용력 측정 장치 개발(II)

  • 박진 (서울여자대학교)
  • Published : 2003.12.31

Abstract

The purpose of this study was to develop the uniaxial force plate system which is measured by the vertical force. The VGRF(vertical ground reaction force) 1.0 was composed of 2 bath digital scales, 2 indicaters, and analyzing software. This system was newly renovated to VGRF 2,0 which are 2 industrial digital scales, 2 adjustable indicators, and enforced analyzing software. Changes of the new system were as follows. First, the height of the plate was 75% lower than before. Second, sensing ability of the load cell was changed from 90 - 0.05kg to 300 - 0.1kg. Third, the speed of data processing was changed from 17 per second to 60 per second. Fourth, analyzing software was enforced to develop and calculate the data. For the test of the system, two different types(bare foot, high-heeled shoes) gait was adopted. highly skilled female walker(23yrs, height 165cm, body mass 46.8kg) participated for the experimental study. During the dynamic performance(gait analysis), the data of each load cell were very similar to the previous studies. Specifically, bare foot walking had less vertical force than high-heeled shoes. Consequently, VGRF 2.0 can sense the general dynamic movements as well as static load conditions.

Keywords

References

  1. 박진, 안병화.(2001). 수직 반작용력 측정장치 개발. 한국운동역학회지, 10(2), 57-65.
  2. 한국산업규격 전기식 저울, 공업진흥청 고시 88-1261.
  3. Bosco, C.(1999). Strength Assessment with the Cosco's Test. Italian Society of Sport Science.
  4. Craik, R.L., & Oatis, C.A.(1995). Gait Analysis-theory and application. St. Louis, MI: Mosby.
  5. Davis, B.L., Perry, J.E., Neith, D.C., & Waters, K.C.(1998). A device for simultaneous measurement of pressure and shear force distribution on the plantar surface of the foot. Journal of Applied Biomechanics, 14, 93-104.
  6. Kistler Manual(2000). Quattro Jump for Superior Athletic Performance.
  7. Hull, M.L., Brew, R., & Hawkins, D.(1995). A new force plate desing incorporation octagonal strain rings. Journal of Applied Biomechanics, 11, 311-321.
  8. Lord, M., Hosein, R., & Williams, R.B.(1992). Method for in-shoe shear stress measurement. Journal of Biomedical Engineering, 14, 181-186. https://doi.org/10.1016/0141-5425(92)90049-Q
  9. Nigg, B.M.(1994). Biomechanics of the Musculo-skeletal System. West Sussex, England: John Wiley & Sons Ltd.(edited by Nigg, B.M. & Herzog, W.)
  10. Perry, J.(1992). Gait Analysis - normal and pathological function. New York, NY: SLACK Inc.
  11. Tappin, J.W., Pollard, J., & Beckett, E.A.(1980). Method of measuring 'shearing' forces on the sole of the foot. Clinical Physics and Physiological Measurement, 1, 83-85. https://doi.org/10.1088/0143-0815/1/1/006
  12. Shrive, N.(1994). Biomechanics of the Musculo-skeletal System. West Sussex, England: John Wiley & Sons Ltd.(edited by Nigg, B.M. & Herzog, W.)