• Title/Summary/Keyword: Force Measurement

Search Result 1,622, Processing Time 0.031 seconds

Absorption analysis of streptavidin-biotin complexes using AFM (AFM을 이용한 스트렙타비딘-바이오틴 단백질 복합체의 흡착 분석)

  • Park, Jee-Eun;Kim, Dong-Sun;Choi, Ho-Jin;Shin, Jang-Kyoo;Kim, Pan-Kyeom;Lim, Geun-Bae
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.237-244
    • /
    • 2006
  • Atomic force microscope (AFM) has become a common tool for the structural and physical studies of biological macromolecules, mainly because it provides the ability to perform experiments with samples in a buffer solution. In this study, structure of proteins and nucleic acids has been studied in their physiological environment that allows native intermolecular complexes to be formed. Cr and Au were deposited on p-Si (100) substrate by thermal evaporation method in sequence with the thickness of $200{\AA}$ and $500{\AA}$, respectively, since Au is adequate for immobilizing biomolecules by forming a self-assembled monolayer (SAM) with semiconductor-based biosensors. The SAM, streptavidin and biotin interacted each other with their specific binding energy and their adsorption was analyzed using the Bio-AFM both in a solution and under air environment. A silicon nitride tip was used as a contact tip of Bio-AFM measurement in a solution and an antimony doped silicon tip as a tapping tip under air environment. Actual morphology could also be obtained by 3-dimensional AFM images. The length and agglomerate size of biomolecules was measured in stages. Furthermore, $R_{a}$ (average of surface roughness) and $R_{ms}$ (mean square of surface roughness) and surface density for the adsorbed surface were also calculated from the AFM image.

Sensing Technologies for Grain Crop Yield Monitoring Systems: A Review

  • Chung, Sun-Ok;Choi, Moon-Chan;Lee, Kyu-Ho;Kim, Yong-Joo;Hong, Soon-Jung;Li, Minzan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.408-417
    • /
    • 2016
  • Purpose: Yield monitoring systems are an essential component of precision agriculture. They indicate the spatial variability of crop yield in fields, and have become an important factor in modern harvesters. The objective of this paper was to review research trends related to yield monitoring sensors for grain crops. Methods: The literature was reviewed for research on the major sensing components of grain yield monitoring systems. These major components included grain flow sensors, moisture content sensors, and cutting width sensors. Sensors were classified by sensing principle and type, and their performance was also reviewed. Results: The main targeted harvesting grain crops were rice, wheat, corn, barley, and grain sorghum. Grain flow sensors were classified into mass flow and volume flow methods. Mass flow sensors were mounted primarily at the clean grain elevator head or under the grain tank, and volume flow sensors were mounted at the head or in the middle of the elevator. Mass flow methods used weighing, force impact, and radiometric approaches, some of which resulted in measurement error levels lower than 5% ($R^2=0.99$). Volume flow methods included paddle wheel type and optical type, and in the best cases produced error levels lower than 3%. Grain moisture content sensing was in many cases achieved using capacitive modules. In some cases, errors were lower than 1%. Cutting width was measured by ultrasonic distance sensors mounted at both sides of the header dividers, and the errors were in some cases lower than 5%. Conclusions: The design and fabrication of an integrated yield monitoring system for a target crop would be affected by the selection of a sensing approach, as well as the layout and mounting of the sensors. For accurate estimation of yield, signal processing and correction measures should be also implemented.

Effects of Norepinephrine and Neuropeptide Y on the Contractility of Small Mesenteric Artery from 2K1C and DOCA-Salt Hypertensive Rats

  • Nam, Sang-Chae;Kang, Seong-Su;Kim, Won-Jae;Lee, Jong-Un
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.1
    • /
    • pp.55-61
    • /
    • 2000
  • The present study was conducted to investigate the possible role of the sympathetic nervous system in two-kidney, one clip (2K1C) and deoxycorticosterone acetate (DOCA)-salt hypertension. 2K1C and DOCA- salt hypertension were made in Sprague-Dawley rats. Four weeks after induction of hypertension, systolic blood pressure measured in conscious state was significantly higher in 2K1C $(216{\pm}18\;mmHg)$ and DOCA-salt $(205{\pm}29\;mmHg)$ groups than that in control $(128{\pm}4\;mmHg).$ The third branches (<300 ${\mu}m$ in outer diameter) of the mesenteric artery were isolated and cut into ring segments of $2{\sim}3$ mm in length. Each ring segment was mounted in tissue bath and connected to a force displacement transducer for measurement of isometric tension. The arterial rings were contracted by application of norepinephrine (NE) in a dose-dependent manner. The amplitude of the NE-induced contraction of the vessels was significantly larger in hypertension than in control. The NE-induced contraction was significantly enhanced by neuropeptide Y (NPY) in hypertension. Reciprocally, NPY-elicited vasocontraction was increased by NE in hypertension. These results suggest that the sympathetic nervous system contributes to the development of 2K1C and DOCA-salt hypertension.

  • PDF

A Study on the Correlation Improvement between FEA and Test for a Pedestrian Lower Legform Impact (보행자보호 Lower Legform 충격의 해석 대 시험 상관성 개선에 관한 연구)

  • Park, Dong-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposed the finite element analysis technique for improving the correleration accuracy between FEA and test on a pedestrian lower legform impact. Europe has been evaluating the bumper pedestrian impact by Euro-NCAP, and it will also be applied in a domestic area by K-NCAP in 2013. By using the compression test result of bending resisting stiffener, a pedestrian bumper modeling guide was presented by analayzing the force-displacement curve of stiffener. And by using the sensor measurement results in car pedestrian test, pedestrian impact behavior was analyzed between test and finite element analysis result. Finally, the finite element analysis guide for a pedestrian bumper impact was presented to improve the correleration accuracy.

Effects of Water Exercise on the Foot Pressure Distribution of a Female Adult with Hemiplegia: A Biomechanical Case Study

  • Lee, In-Woo;Kim, Jin-Ki;Yang, Jeong-Ok;Lee, Joong-Sook;Lee, Bom-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.2
    • /
    • pp.179-187
    • /
    • 2013
  • This case study was conducted to determine the effects of water exercise on the foot pressure distribution (FPD) of persons who have a hemiplegia. A 43-year old female with hemiplegia acquired at the age of 3 years was selected from a local disability program. A 12-week water exercise program (60 min. per session and twice a week) focusing on gait training was developed and implemented as the intervention of this study. A recent product of the Pedar-X (Novel, Germany) was used to measure the FPD of hemiplegic gait before and after the intervention. Variables considered in this study included the average pressure (AP), contact area (CA), maximum pressure (MP), ground reaction force (GRF), and center of pressure (COP). The data collected were analyzed via the descriptive statistics and qualitative analyses on the graphical presentations of the FPD. Results revealed that the AP and CA of the hemiplegic foot was considerably increased before and after the intervention. Similar results were also found in the MP and GRF. Additionally, the graphical route of the COP related to hemiplegic foot was changed in a positive way after the intervention. It can be concluded that water exercise may be beneficial to restore hemiplegic gait. Limitations related to measurement and generalizability are further discussed.

Fabrication and Characterization of Organic Thin-Film Transistors by Using Polymer Gate Electrode (고분자 게이트 전극을 이용한 유기박막 트랜지스터의 제조 및 소자성능에 관한 연구)

  • Jang, Hyun-Seok;Song, Ki-Gook;Kim, Sung-Hyun
    • Polymer(Korea)
    • /
    • v.35 no.4
    • /
    • pp.370-374
    • /
    • 2011
  • A conductive PANI solution was successfully fabricated by doping with camphorsulfonic acid and the polymerization of aniline and the confirmation of doping were characterized by FTIR spectroscopy. In organic thin film transistors, PANI gate electrodes were spin-coated on a PES substrate and their conductivity variations were monitored by a 4-probe method with different annealing temperatures. The surface properties of PANI thin films were investigated by an AFM and an optical microscope, OTFTs with PANI gate electrode had characteristics of carrier mobility as large as 0.15 $cm^2$/Vs and on/off ratio of $2.4{\times}10^6$, Au gate OTFTs with the same configuration were fabricated to investigate the effect of polymer gate electrode for the comparison of device performances. We could obtain the comparable performances of PANI devices to those of Au gate devices, resulting in an excellent alternative as an electrode in flexible OTFTs instead of an expensive Au electrode.

Effects of epilayer growth temperature on properties of undoped GaN epilayer on sapphire substrate by two-step MOCVD (2단계 MOCVD법에 의해 사파이어 기판 위 성장된 undoped GaN 에피박막의 특성에 미치는 고온성장 온도변화의 영향)

  • Chang K.;Kwon M. S.;Cho S. I.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.222-228
    • /
    • 2005
  • Undoped GaN epitaxial layer was grown on c-plane sapphire substrate by a two-step growth with metalorganic chemical vapor deposition(MOCVD). We have investigated the effects of the variation of final growth temperature on surface morphology, roughness, crystal quality, optical property, and electrical property In a horizontal MOCVD reactor, the film was grown at 300 Tow low-pressure with a fixed nucleation temperature of $500^{\circ}C$, varing the final growth temperature from $850\~1050^{\circ}C$ . The undoped GaN epilayers were characterized by atomic force microscopy, high-resolution x-ray diffractometer, photoluminescence, and Hall effect measurement.

New Evaluation of Initial Growth Mechanisms of Hydroxyapatite on Self-assembled Collagen Nanofibrils by Using ToF-SIMS and AFM Techniques

  • Park, Young-Jae;Choi, Gyu-Jin;Lee, Tae-Geol;Lee, Won-Jong;Moon, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.397-397
    • /
    • 2010
  • Bone is considered as hierarchically organized biocomposites of organic (collagen) and inorganic (hydroxyapatite) materials. The precise structural dependence between hydroxyapatite (HAp, $Ca_{10}(PO_4)_6(OH)_2)$ crystals and collagen fibril is critical to unique characteristics of bone. To meet those conditions and obtain optimal properties, it is essential to understand and control the initial growth mechanisms of hydroxyapatite at the molecular level, such as other nano-structured materials. In this study, collagen fibrils were prepared by adsorbing native type I collagen molecules onto hydrophobic surface. Hydrophobicity was introduced on the Si wafer surface by using PECVD (plasma enhanced chemical vapor deposition) method and cyclohexane as a precursor. Biomimetic nucleation and growth of HAp on the self-assembled collagen nanofibrils were occurred through incubation of the sample in SBF (simulated body fluid). Chemical and morphological evolution of HAp nanocrystals was investigated by surface-sensitive analytical techniques such as ToF-SIMS (Time-of-Flight Secondary Ion Mass Spectrometry) and AFM (Atomic Force Microscopy) in the early growth stages (< 24 hrs). The very initial stages (< 12 hrs) of mineralization could be clearly demonstrated by ToF-SIMS chemical mapping of surface. In addition to ToF-SIMS and AFM measurement, scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction analysis were conducted to characterize the HAp layer in the late stages. This study is of great importance in the growth of real bone-like materials with a structure analogous to that of natural bones and the development of biomimetic nanomaterials.

  • PDF

The Development of the Contamination Prevention Module of an Optical Window Using Ultrasonic Waves (초음파를 이용한 광학창 오염방지 모듈 개발)

  • Lee, ChangHee;Jeon, KiMun;Shin, JaeSoo;Yun, JuYoung;Cho, Seonghyun;Kang, Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • We developed the contamination prevention module of an optical window for an In-Situ Particle Monitor (ISPM) system. the core part of the module is the generator of an ultrasonic wave and the module is to remove particles stuck to the window by the transfer of the wave force to the window surface. In order to enhance transfer efficiency of the waves the frequency of the ultrasonic wave was optimized and a low impedance material (plexiglass) and a soft sealing material (Si rubber) were used. The ISPM with the developed module was installed at the exhaust line of a BPSG CVD equipment and the effect of the module was verified.

Observation of Residual PMMA on Graphene Surface by Using IR-Absorption Mapping

  • Oh, Hye Min;Kim, Yong Hwan;Kim, Hyojung;Park, Doo Jae;Lee, Young Hee;Jeong, Mun Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.292.2-292.2
    • /
    • 2013
  • Graphene, a two-dimensional graphite material consisting of sp2-hybridized carbons. The properties of graphene such as extremely high carrier mobility, high thermal conductivity, low resistivity, large specific make it a promising materail of divices and material. Typically, poly (methyl methacrylate) (PMMA) is used when graphene transfer to other substrates. To remove PMMA on graphene, people used to dip the graphene into the acetone. However, it is known that the remove of PMMA on the graphene is difficult to completely using the acetone. Therefore, to remove the PMMA on the graphene surface, many research groups have employed various methods such as the thermal treatment, photothermal method, and other solvent. Nevertheless, a part of PMMA still remain on graphene surface. Usually, to observe the residual PMMA on graphene surface, topography of graphene surface scanned by atomic force microscopy is used. However, in that case, we can not distinguish PMMA and other particles. In this study, to confirm the residual PMMA on graphene surface, we employed novel measurement technique which is available to distinguish PMMA and other particles by means of photothermal effect.

  • PDF