• 제목/요약/키워드: Force Components

검색결과 1,049건 처리시간 0.027초

FCEV 구동용 DC-DC 컨버터 가변 DC-link 전압 제어에 의한 PWM 인버터의 전류 왜곡 저감 (Reduction of Current Distortion in PWM Inverter by Variable DC-link Voltage of DC-DC Converter for FCEV)

  • 고안열;김도윤;이정효;김영렬;원충연
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.572-581
    • /
    • 2014
  • A design and control method of DC/DC converter, which can control variable DC-link voltage to drive a fuel cell electric vehicle (FCEV), is proposed in this study. Given that a fuel cell has low-voltage and high-current characteristics, the required voltage for operating motor must be output through the DC/DC boost converter in the system to drive an FCEV. The proposed converter can choose the output voltage of battery or fuel cell in consideration of the driving mode, as well as control DC-link voltage in accordance with the back electromotive force. The switching lag-time to prevent shortage of pulse-width modulation inverter arms makes distorted current waveform caused by voltage distortion. Through this control method, the proposed converter can reduce the output voltage distortion and current ripple of the inverter, thereby reducing the distorted torque. Simulations and experimental results are presented to verify the reliability of the proposed DC/DC converter.

CMP 폐슬러리내의 필터링된 연마 입자 재활용에 관한 연구 (A study on the recycle of reused slurry abrasives)

  • 김기욱;서용진;박성우;정소영;김철복
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.50-53
    • /
    • 2003
  • CMP (chemical mechanical polishing) process remained to solve several problems in deep sub-micron integrated circuit manufacturing process. especially consumables (polishing pad, backing film, slurry, pad conditioner), one of the most important components in the CMP system is the slurry. Among the composition of slurries (buffer solution, bulk solution, abrasive particle, oxidizer, inhibitor, suspension, antifoaming agent, dispersion agent), the abrasive particles are important in determining polish rate and planarization ability of a CMP process. However, the cost of abrasives is still very high. So, in order to reduce the high COO (cost of ownership) and COC (cost of consumables) in this paper, we have collected the silica abrasive powders by filtering after subsequent CMP process for the purpose of abrasive particle recycling. And then, we have studied the possibility of recycle of reused silica abrasive through the analysis of particle size and hardness. Also, we annealed the collected abrasive powders to promote the mechanical strength of reduced abrasion force. Finally, we compared the CMP characteristics between self-developed KOH-based silica abrasive slurry and original slurry. As our experimental results, we obtained the comparable removal rate and good planarity with commercial products. Consequently, we can expect the saving of high cost slurry.

  • PDF

Study of Stay Vanes Vortex-Induced Vibrations with different Trailing-Edge Profiles Using CFD

  • Neto, Alexandre D'Agostini;Saltara, Fabio
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.363-374
    • /
    • 2009
  • The 2D flow around 13 similar stay-vane profiles with different trailing edge geometries is investigated to determinate the main characteristics of the excitation forces for each one of them and their respective dynamic behaviors when modeled as a free-oscillating system. The main goal is avoid problems with cracks of hydraulic turbines components. A stay vane profile with a history of cracks was selected as the basis for this work. The commercial finite-volume code $FLUENT^{(R)}$ was employed in the simulations of the stationary profiles and, then, modified to take into account the transversal motion of elastically mounted profiles with equivalent structural stiffness and damping. The k-$\omega$ SST turbulence model is employed in all simulations and a deforming mesh technique used for models with profile motion. The static-model simulations were carried out for each one of the 13 geometries using a constant far field flow velocity value in order to determine the lift force oscillating frequency and amplitude as a function of the geometry. The free-oscillating stay-vane simulations were run with a low mass-damping parameter ($m^*{\xi}=0.0072$) and a single mean flow velocity value (5m/s). The structural bending stiffness of the stay-vane is defined by the Reduced Velocity parameter (Vr). The dynamic analyses were divided into two sets. The first set of simulations was carried out only for one profile with $2{\leq}Vr{\leq}12$. The second set of simulations focused on determining the behavior of each one of the 13 profiles in resonance.

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

Comparison of Vasodilator Effects of Platycodin D and $D_3$ in Rats

  • Lim, Dong-Yoon;Kim, Byeong-Cheol;Lee, Eun-Bang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제7권3호
    • /
    • pp.149-155
    • /
    • 2003
  • The aim of the present study was to examine the effects of platycodin D and $D_3$, which are active components derived from the roots of Platycodon grandiflorum A. DC., on the contractile force of the i3olated rat aorta and blood pressure of the anesthetized rat, and also to elucidate its mechanism of action. Both phenylephrine (an adrenergic ${\alpha}1$-receptor agonist) and high potassium (a membranedepolarizing agent) caused great contractile responses in the isolated aortic strips. Platycodin D at high concentration $(24{\mu}g/ml)$ inhibited contractile responses induced by phenylephrine $(10^{-5}\;M)$ and high potassium $(5.6{\times}10^{-2}\;M)$, while low concentrations of platycodin D $(4{\sim}8{\mu}g/ml$) did not affect those responses. However, platycodin $D_3\;(8{\sim}32{\mu}g/ml)$ did not alter the contractile responses evoked by phenylephrine and high $K^+$. Interestingly, the infusion of platycodin $D_3$ (1.0 mg/kg/30 min) significantly reduced the pressor responses induced by intravenous norepinephrine. However, platycodin $D_3$ (1.0 mg/kg/30 min) did not affect them. Taken together, these results show that intravenously administered platycodin D depresses norepinephrine-induced pressor responses in the anesthetized rat, at least partly through the blockade of adrenergic ${\alpha}1$-receptors. Platycodin D also caused vascular relaxation in the isolated aortic strips of the rat via the blockade of adrenergic ${\alpha}1$-receptors, in addition to an unknown direct mechanism. However, platycodin $D_3$ did not affect both norepinephrine-induced pressor responses and the isolated rat aortic contractile responses evoked by phenylephrine and high potassium. Based on these results, there seems to be much difference in the mode of action between platycodin D and platycodin $D_3$.

기둥-보 용접접합부의 보단부 스캘럽형상과 탄소성 거동에 관한 실험적 연구 - 600MPa(SM570TMC)의 경우 - (Study on Elasto-Plastic Behavior of Column to Beam Connection with 600MPa High Performance Steel(SM 570 TMC))

  • 김종락;김성배;권준엽
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.691-700
    • /
    • 2008
  • 최근 건축구조물의 구조는 다양한 형태의 복잡한 건축물이 구현되고 있다. 이러한 건축구조물의 복합 다양성은 수평저항력에 효과적 으로 저항하기 위해 강재와 접합부의 요구성능이 점차 중요시되고 있다. 접합부는 형상의 불연속과 응력집중 및 다축응력 등이 발생되는 부분으로 골조전체의 변형능력에 큰 영향을 미치고 강성과 인성을 결정하는 중요부위이다. 본 연구에서는 고강도 고성능강 적용에 대한 인성평가를 위해 구조체의 기둥-보 접합부를 빌트업 H형강의 T형 기둥-보 용접접합부로 제작하여 실대실험을 수행하였다. 실험변수는 응력집중 및 형상의 불연속이 발생되는 보 스캘럽을 중심으로 논스캘럽(Non-Scallop)과 종래형 스캘럽, 개량형 스캘럽으로 제작하여 스캘럽 형상이 접합부의 인성에 미치는 영향과 고강도 고성능강의 건축구조물 적용성을 평가하였다. 기존의 기둥-보 용접접합부에 대한 평가방법을 기초로 최근 개발된 고강도 고성능강의 초고층 건축물 적용을 위한 내진설계 자료를 제시하였다.

자동변속기 유성기어 소음을 고려한 시스템 분석용 프로그램 개발 및 적용에 관한 연구 (Development of a Design and Analysis Program for Automatic Transmission Applications to Consider the Planetary Gear Noise and Its Adaptation)

  • 이현구;이상화;김무석;홍사만;김시웅;유동규;권현식;아멧칼만
    • 한국소음진동공학회논문집
    • /
    • 제25권7호
    • /
    • pp.487-495
    • /
    • 2015
  • A generalized special program called planetary transmission analysis(here in after PTA) is developed to improve planetary gear noise in automatic transmission. PTA is capable of analyzing any typical one-degree-of-freedom automatic transmission gear train containing any number of simple, compound or complex-compound planetary gear sets. The kinematics module in PTA can compute the rotational speeds of gears and carriers and calculate the order frequencies to predict the planetary noise components. The power flow analysis module performs a complete static force analysis providing forces, moments, or torques of gears, bearings, clutches and connections. Based on the given type and number of planetary gear sets, the search algorithm determines all possible kinematic configurations and gear tooth combinations in a required set of gear ratios, while eliminating whole kinematic redundancies and unfavorable clutching sequences. By using PTA program, planetary internal speeds of new developed automatic transmission are early obtained; therefore, possibility of the noise problem could be predicted in early design stage. As implementing PTA in planetary gear NVH development procedure, planetary gear noise was successfully reduced by 10 dBA.

Effect of the Calpain System on Volatile Flavor Compounds in the Beef Longissimus lumborum Muscle

  • Yang, Jieun;Dashdorj, Dashmaa;Hwang, Inho
    • 한국축산식품학회지
    • /
    • 제38권3호
    • /
    • pp.515-529
    • /
    • 2018
  • The present study was designed to investigate the effects of calpain system on the formation of volatile flavor compounds in Hanwoo beef. In the first experiment (exp.1), Longissimus lumborum (LL) muscle samples were injected with solutions containing 50 mM $CaCl_2$ or 50 mM $ZnCl_2$ and 154 mM NaCl respectively, and aged for 7 d at $4^{\circ}C$. In the second experiment (exp.2), the ground LL muscle was incubated with the aforementioned solutions containing cathepsin inhibitor. The injection with $CaCl_2$ solution greatly elevated the calpain activity and concomitantly, significantly decreased the Warner-Bratzler shear force (p<0.05). The pH, meat color and cooking loss did not differ (p>0.05) between the treatment groups. A total of 51 volatile compounds were identified using the solid phase microextraction with gas chromatography (SPME-GC). Results on volatile analyses from the both experiments showed that the injection with calcium ions led to significant increase (p<0.05) concentrations of pyrazines and sulfuric compounds. These results coincide with a higher rate of protein degradation due to the $CaCl_2$ injection as compared to the control group. Significantly (p<0.05) higher levels of lipid oxidation derived-aldehydes were found in the samples with $ZnCl_2$. The exp.1 showed that cathepsin inhibitors had no effect on the formation of volatile flavor components after 7 d of aging. These results imply that the proteolytic activity of the calpain system is associated with generation of volatile compounds of chiller-aged beef, while the role of cathepsins is likely very limited.

Ink setting and back trap mottle

  • 김병수;박종열
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 춘계학술발표논문집
    • /
    • pp.70-79
    • /
    • 2003
  • Paper coating can give smoothness surface and good printability to uncoated paper. Macro roughness of base paper would be decreasing its groove and grit in view of side. Nevertheless its improving effect for paper, some kind of problem is showing in the fine coated paper. Especially, back trap mottle is one of serious problems in printing with fine coated paper. Printers can not adjust conditions to overcome the problem. Also large amounts of paper can be rejected. There are many factors that influence back trap mottle. However it is not clear what the important parameters are in back trap mottle. Back trap mottle has some relationship with ink setting but good guidelines are not clear. Back trap mottle has been linked to non-uniform ink setting. We do not know how much variation in setting we can tolerate. Other mottle issues such as micro-picking and ink refusal are still common. This paper was prepared to identify correlation with ink setting and delta ink density obtained from experiment and then tried to find out some relationships with ink setting and back trap mottle. Basically fine calcium carbonate and ciay was used for main components and coarse calcium carbonate was mixed in two fine pigments to change its porosity and ink acceptance. Micro ink tack force at KRK printing tester was adapted to measure ink setting rate. KRK units were used for back trap mottle simulation and two printed samples were prepared to check delta ink density. Clay base coating has more fast ink setting time than calcium carbonate's though smoothness of clay was better than calcium carbonate. It could be explained by that clay has finer pore in its coating than calcium carbonate. DID(delta ink density) has shown a good correlation with ink setting time from micro ink tack. The total pore volume of coating layer did not match with ink setting and DID. From the results we might conclude coating that has fine pore size around 0.05 ${\mu}m$ can be exposed to high possibility of back trap mottle.

  • PDF

화장품을 바를 때 피부 마찰계수의 변화와 주관적인 평가와의 상관관계 연구 (A study on correlation between frictional coefficients and subjective evaluation while rubbing cosmetic product on skin)

  • 권영하;권현준;랑문정;이수민
    • 감성과학
    • /
    • 제8권4호
    • /
    • pp.385-391
    • /
    • 2005
  • 화장품을 바를 때 피부와 손가락 사이에서 일어나는 마찰계수는 화장품의 주관적 평가에 많은 영향을 주는 요소이다. in-vivo상태에서 피부와 접촉자 간의 마찰계수는 접촉자의 모양이나 거칠기의 정도 그리고 누르는 하중에 따라 변할 수 있다. 본 실험에서는 리니어 모터와 다축 로드셀을 이용하여 여러 가지 접촉자를 in-vivo상태에서 직접 피부에 접촉시키고 실시간으로 마찰계수를 측정할 수 있는 장치를 개발하였다. 이 장치를 이용하여 피부와 접촉자 간의 마찰계수를 측정하고 그 데이터를 화장품을 바를 때의 전후와 비교$\cdot$분석하였다. 또한 화장품을 바를 때 주관적인 평가에서 이용되는 형용사를 조사하며 마찰계수와의 그 상관관계를 분석하였다. 그 결과, 피부와 접촉자 간의 마찰계수는 화장품의 종류와 접촉자의 성질에 따라 0.17-1.2사이에서 나타나며, 주관적인 평가 또한 화장품을 바른 후 시간의 경과함에 따라 변하며, 그것은 마찰계수와 관련이 있음을 확인할 수 있었다.

  • PDF