• Title/Summary/Keyword: Foraminal

Search Result 69, Processing Time 0.025 seconds

The Clinical Comparison between Open Surgery and Percutaneous Endoscopic Lumbar Discectomy in Extraforaminal Lumbar Disc Herniation

  • Jeong, Jin-Seok;Lee, Sang-Ho;Lee, Sang-Jin;Hwang, Byeong-Wook
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.413-418
    • /
    • 2006
  • Objective : The objective of this study is to evaluate and compare the clinical results between classical open surgery and percutaneous endoscopic lumbar discectomy[PELD] in cases of extraforaminal lumbar disc herniation. Methods : We obtained the clinical data from 47 patients with extraforaminal lumbar disc herniations who underwent the open paramedian muscle-splitting approach or percutaneous endoscopic lumbar discectomy[PELD] between January 2001 and February 2004. This study consisted of patients with soft disc extraforaminal herniations. The patients were assessed with the visual analogue scale[VAS] and MacNab's criteria before surgery, just before discharge, and postoperative 1 year. Results : There were 25 cases in the open surgery group and 22 cases in the PELD group. The average operating time was $78{\pm}36.71\;min$ in the PELD group and $110{\pm}29.68\;min$ in the open surgery group. The mean hospital stay was $2.73{\pm}2.62$ days in the PELD group and $7.68{\pm}2.59$ days in the open surgery group. VAS decreased from $8.34{\pm}0.66$ to $1.29{\pm}2.27$ in the PELD group and from $8.40{\pm}1.40$ to $1.70{\pm}1.72$ in the open surgery group at the one-year follow-up. The success rate of PELD was 86.4%, compared with 80.0% for open surgery. However, there were no statistically significant difference between two groups for success rate and VAS. Conclusion : Although the success rates were similar in both groups, PELD is less invasive, faster, and safe procedure than open surgery for extraforaminal disc herniation in selected patients.

The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload

  • Altuwaijri, Shahad Mohammmed;Alotaibi, Hanan Nejer;Alnassar, Talal Mughaileth
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.22-31
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate the misfit and screw preload at the implant abutment connection of implant supported fixed dental prosthesis with cantilever (ICFDP) manufactured using different digital manufacturing techniques and to compare the screw preload before and after cyclic loading. MATERIALS AND METHODS. Mandibular jaw model with four intra-foraminal implants was scanned using digital scanner. Stereolithography file was used to design a framework with nonengaging (NE) abutments and 10 mm cantilever distal to one terminal implant. Five frameworks were constructed using combined digital-conventional techniques (CAD-cast), and five frameworks were constructed using three-dimensional printing (3DP). Additional CAD-cast framework was constructed in a way that ensures passive fit (PF) to use as control. Scanning electron microscope (SEM) measured the implant abutment connection misfit. Sixty screws were used on the corresponding frameworks. Screws were torqued and pre-cyclic loading reverse torque value (RTV) was recorded. Frameworks were subjected to 200,000 loading cycles with a loading point 9 mm from the center of terminal implants adjacent to the cantilever and post-cyclic loading RTVs were recorded. RESULTS. Microscopic readings showed significant differences between frameworks. PF demonstrated the lowest measurements of 16.04 (2.6) ㎛ while CAD-cast demonstrated the highest measurements of 29.2 (3.1) ㎛. In all groups, RTVs were significantly lower than the applied torque. Post-cyclic loading RTV was significantly lower than pre-cyclic loading RTV in PF and 3DP frameworks. Differences in RTVs between the three manufacturing techniques were insignificant. CONCLUSION. Although CAD-cast and three-dimensionally printed (3DP) both produce frameworks with clinically acceptable misfit, 3DP might not be the technique of choice for maintaining screw's preload stability under an aggressive loading situation.

Quality of life, patient preferences, and implant survival and success of tapered implant-retained mandibular overdentures as a function of the attachment system

  • Ilze Indriksone;Pauls Vitols;Viktors Avkstols;Linards Grieznis;Kaspars Stamers;Susy Linder;Michel Dard
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.3
    • /
    • pp.194-206
    • /
    • 2023
  • Purpose: A novel attachment system for implant-retained overdentures (IRODs) with novel material combinations for improved mechanical resilience and prosthodontic success (Novaloc) has been recently introduced as an alternative to an existing system (Locator). This study investigated whether differences between the Novaloc and Locator attachment systems translate into differences in implant survival, implant success, and patient-centered outcomes when applied in a real-world in-practice comparative setting in patients restored with mandibular IRODs supported by 2 interforaminal implants (2-IRODs). Methods: This prospective, intra-subject crossover comparison compared 20 patients who received 2 intra-foraminal bone level tapered implants restored with full acrylic overdentures using either the Locator or Novaloc attachment system. After 6 months of function, the attachment in the corresponding dentures was switched, and the definitive attachment system type was delivered based on the patient's preference after 12 months. For the definitive attachment system, implant survival was evaluated after 24 months. The primary outcomes of this study were oral health-related quality of life and patient preferences related to prosthetic and implant survival. Secondary outcomes included implant survival rate and success, prosthetic survival, perceived general health, and patient satisfaction. Results: Patient-centered outcomes and patient preferences between attachment systems were comparable, with relatively high overall patient satisfaction levels for both attachment systems. No difference in the prosthetic survival rate between study groups was detected. The implant survival rate over the follow-up period after 24 months in both groups was 100%. Conclusions: The results of this in-practice comparison indicate that both attachment systems represent comparable candidates for the prosthodontic retention of 2-IRODs. Both systems showed high rates of patient satisfaction and implant survival. The influence of material combinations of the retentive system on treatment outcomes between the tested systems remains inconclusive and requires further investigations.

Factors Affecting Cage Obliquity and the Relationship between Cage Obliquity and Radiological Outcomes in Oblique Lateral Interbody Fusion at the L4-L5 Level

  • CheolWon Jang;SungHwan Hwang;Tae Kyung Jin;Hyung Jin Shin;Byung-Kyu Cho
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.6
    • /
    • pp.703-715
    • /
    • 2023
  • Objective : This retrospective study investigated the factors that affect cage obliquity angle despite orthogonal maneuvers performed during oblique lateral interbody fusion (OLIF) and assessed the relationship between cage obliquity angle and radiological outcomes post-surgery. Methods : Twenty-nine males who underwent L4-L5 OLIF for lumbar degenerative disease between 2019 and 2021 with a followup duration greater than 12 months were analyzed. Radiological parameters were measured including psoas muscle volume, total psoas area index (total psoas muscle area [cm2]/height squared [m2]), distance from the iliac artery to the origin of the psoas muscle (DIAPM), angle between the origin of the psoas muscle and the center of the vertebral disc (APCVD), iliac crest height, disc height, lumbar flexibility (lumbar flexion angle minus extension angle), cage location ratio, cage-induced segmental lumbar lordosis (LL) (postoperative index level segmental LL minus used cage angle), foraminal height changes, fusion grade. Results : DIAPM, APCVD, iliac crest height, postoperative index level segmental LL, and cage-induced segmental LL were significantly correlated with OLIF cage obliquity angle. However, other radiological parameters did not correlate with cage obliquity. Based on multiple regression analysis, the predictive equation for the OLIF cage obliquity angle was 13.062-0.318×DIAPM+0.325×1APCVD+0.174×iliac crest height. The greater the cage obliquity, the smaller the segmental LL compared to the cage angle used. Conclusion : At the L4-L5 level, OLIF cage obliquity was affected by DIAPM, APCVD, and iliac crest height, and as the cage obliquity angle increases, LL agnle achievable by the used cage could not be obtained.

Neurovascular Morphometric Aspect in the Region of Cranio-Cervical Junction (두개와 경추의 이행부에서 뇌신경계와 혈관계에 대한 형태학적 계측)

  • Lee, Kyu;Bae, Hack-Gun;Choi, Soon-Kwan;Yun, Seok-Mann;Doh, Jae-Won;Lee, Kyeong-Seok;Yun, Il-Gyu;Byun, Bark-Jang
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1094-1102
    • /
    • 2001
  • Objective : During the trans-condylar or trans-jugular approach for the lesion of cranio-cervical junction(CCJ), its necessary to identify the accurate locations of vertebral artery(VA), internal jugular vein(IJV) and its related lower cranial nerves. These neurovascular structures can also be damaged during the operation for vascular tumor or traumatic aneurysm around extra-jugular foramen, because of their changed locations. To reduce the neurovascular injury at the operation for CCJ, morphometric relationship of its surrounding neurovascular structures based on the tip of the transverse process of atlas(C1 TP), were studied. Materials & Methods : Using 10 adult formalin fixed cadavers, tip of mastoid process(MT) and TPs of atlas and axis were exposed bilaterally after removal of occipital and posterior neck muscles. Using standard caliper, the distances were measured from the C1 TP to the following structures : 1) exit point of VA from C1 transverse foramen, 2) branching point of muscular artery from VA, 3) entry point of VA into posterior atlanto-occipital membrane(AOM), 4) branching point of C-1 nerve. In addition, the distances were measured from the mid-portion of the posterior arch of atlas to the entry point of the VA into AOM and to the exit point of the VA from C1 transverse foramen. After removal of the ventrolateral neck muscles, neurovascular structures were exposed in the extra-jugular foraminal region. Distances were then measured from the C1 TP to the following structures : 1) just extra-jugular foraminal IJV and lower cranial nerves, 2) MT and branching point of facial nerve in parotid gland. In addition, distance between MT and branching point of facial nerve was measured. Results : The VA was located at the mean distance of 12mm(range, 10.5-14mm) from the C1 transverse foramen and entered into the AOM at the mean distance of 24mm(range, 22.8-24.4mm) from the C1 TP. The mean distance from the mid portion of the C1 posterior arch was 20.6mm(range, 19.1-22.3mm) to the entry point of the VA into AOM and 38.4mm(range, 34-42.4mm) to the exit point of the VA from C1 transverse foramen. Muscular artery branched away from the posterior aspect of the transverse portion of VA below the occipital condyle at the mean distance of 22.3mm(range, 15.3-27.5mm) from the C1 TP. The C-1 nerve was identified in all specimens and ran downward through the ventroinferior surface of the transverse segment of VA and branched at the mean distance of 20mm(range, 17.7-20.3mm) from the C1 TP. The IJV was located at the mean distance of 6.7mm(range, 1-13.4mm) ventromedially from the lateral surface of the C1 TP. The XI cranial nerve ran downward on the lateral surface of the IJV at the mean distance of 5mm(range, 3-7.5mm) from the C1 TP. Both IX and X cranial nerves were located in the soft tissue between the medial aspect of the internal carotid artery(ICA) and the medial aspect of the IJV at the mean distance of 15.3mm(range, 13-24mm) and 13.7mm(range, 11-15.4mm) from the C1 TP, respectively. The IX cranial nerve ran downward ventroinferiorly crossing the lateral aspect of the ICA. The X cranial nerve ran downward posteroinferior to the IX cranial nerve and descended posterior to the ICA. The XII cranial nerve was located between the posteroinferior aspect of the IX cranial nerve and the posterior aspect of the ICA at the mean distance of 13.3mm(range, 9-15mm) ventromedially from the C1 TP. The distance between MT and C1 TP was 17.4mm(range, 12.5-23.9mm). The VII cranial nerve branched at the mean distance of 10.2mm(range, 6.8-15.3mm) ventromedially from the MT and at the mean distance of 17.3mm(range, 13-21mm) anterosuperiorly from the C1 TP. Conclusion : This study facilitates an understanding of the microsurgical anatomy of CCJ and may help to reduce the neurovascular injury at the surgery around CCJ.

  • PDF

The Relationship between Neural Foraminal Stenosis and Imaging Features of Lumbar Spine MRI in Patients Older Than 60 Years with Lumbar Radiculopathy (요추신경근병증이 있는 60세 이상의 환자에서 신경공 협착과 자기공명영상 평가를 통한 인자와의 상관관계)

  • Kyeyoung Lee;Hee Seok Jeong;Chankue Park;Maeran Kim;Hwaseong Ryu;Jieun Roh;Jeong A Yeom;Jin Hyeok Kim;Tae Un Kim;Chang Ho Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.862-875
    • /
    • 2021
  • Purpose To investigate the MRI features associated with neural foraminal stenosis (NFS) in patients older than 60 years with lumbar (L) radiculopathy. Materials and Methods This study included 133 retrospectively selected patients older than 60 years with lumbar radiculopathy who had undergone a lumbar spine MRI (from January 2018 to April 2018). For L4/L5 and L5/sacral (S)1 levels, NFS was reviewed blindly by two radiologists. Spondylolisthesis, retrolisthesis, disc height loss, disc bulging/herniation/central canal stenosis, ligamentum flavum thickening, and facet hypertrophy were evaluated separately for the NFS and non-NFS groups, and they were compared using univariate and multivariate analyses. Results The univariate analysis revealed that disc height loss (p = 0.006) was associated with NFS for L4/L5. For L5/S1, both spondylolisthesis (p = 0.005) and facet hypertrophy (p = 0.006) were associated with NFS. The multivariate logistic analysis revealed that disc height loss was associated with NFS for L4/L5 [odds ratio (OR) = 4.272; 95% confidence interval (CI) 1.736-10.514]. For L5/S1, spondylolisthesis (OR = 3.696; 95% CI 1.297-10.530) and facet hypertrophy (OR = 6.468; 95% CI 1.283-32.617) were associated with NFS. Conclusion Disc height loss was associated with NFS for L4/L5 and spondylolisthesis and facet hypertrophy were associated with NFS for L5/S1.

Clinical Experiences and Usefulness of Cervical Posterior Stabilization with Polyaxial Screw-Rod System

  • Hwang, In-Chang;Kang, Dong-Ho;Han, Jong-Woo;Park, In-Sung;Lee, Chul-Hee;Park, Sun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.311-316
    • /
    • 2007
  • Objective : The objective of this study is to investigate the safety, surgical efficacy, and advantages of a polyaxial screw-rod system for posterior occipitocervicothoracic arthrodesis. Methods : Charts and radiographs of 32 patients who underwent posterior cervical fixation between October 2004 and February 2006 were retrospectively reviewed. Posterior cervical polyaxial screw-rod fixation was applied on the cervical spine and/or upper thoracic spine. The surgical indication was fracture or dislocation in 18, C1-2 ligamentous injury with trauma in 5, atlantoaxial instability by rheumatoid arthritis (RA) or diffuse idiopathic skeletal hyperostosis (DISH) in 4, cervical spondylosis with myelopathy in 4, and spinal metastatic tumor in 1. The patients were followed up and evaluated based on their clinical status and radiographs at 1, 3, 6 months and 1 year after surgery. Results : A total of 189 screws were implanted in 32 patients. Fixation was carried out over an average of 3.3 spinal segment (range, 2 to 7). The mean follow-up interval was 20.2 months. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-7 lateral masses, as well as the lower cervical and upper thoracic pedicles. Satisfactory bony fusion and reduction were achieved and confirmed in postoperative flexion-extension lateral radiographs and computed tomography (CT) scans in all cases. Revision surgery was required in two cases due to deep wound infection. One case needed a skin graft due to necrotic change. There was one case of kyphotic change due to adjacent segmental degeneration. There were no other complications, such as cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, or implant failure, and there were no cases of postoperative radiculopathy due to foraminal stenosis. Conclusion : Posterior cervical stabilization with a polyaxial screw-rod system is a safe and reliable technique that appears to offer several advantages over existing methods. Further biomechanical testings and clinical experiences are needed in order to determine the true benefits of this procedure.

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.

The Study Intervertebral Foramen Image for the Cervical spine of Posterior Anterio Oblique for the Angle (목뼈 척추사이 공간 관찰을 위한 후·전 사방향 촬영 각도에 관한 연구)

  • Ahn, Byung Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • The Study on the patient is in a clinical researcher is not necessarily pose before after before after dwichim (Pronation) pose with neck-in-law (RAO, LAO) to chwalyoungbeop subjective evaluation experiment looked at objectively. Overview evaluation is a result of measuring the angle of the space between the vertebrae in PACS image $C_2{\sim}C_3$, $C_3{\sim}C_4$, $C_4{\sim}C_5$, $C_5{\sim}C_6$, $C_6{\sim}C_7$, in the angle of the $C_7{\sim}T_1$ $47.4^{\circ}{\pm}3.3$, $50.5^{\circ}{\pm}2.3$, $52.7^{\circ}{\pm}4.2$, $53.2^{\circ}{\pm}1.9$, $53.2^{\circ}{\pm}2.3$, $55.2^{\circ}{\pm}2.3$ was found to show increasing the angle between the ball and the median nerve in the lower neck sagittal grows. In a comparison of the measured angles in foraminal image was not significantly different (P>0.01). Subjective evaluation Recever Operation characteristic to the top, the upper neck hole (foramen) C2 ~ C3-up than conventional $45^{\circ}$ angle of the lower neck, $C_3{\sim}C_4$, were observed in the well $50^{\circ}$ $C_5{\sim}C_6$, $C_6{\sim}C_7$, the $C_7{\sim}T_1$ was observed at $55^{\circ}$ well observed experimental results video recession neck vertebrae son-in-law, son-in-law taken place in an objective evaluation, subjective evaluation of the upper neck after case could be observed at $50^{\circ}$, well in the lower neck $55^{\circ}$.