• 제목/요약/키워드: Foot orthotic devices

검색결과 6건 처리시간 0.018초

밀착형 외측 쐐기 스트랩 깔창의 높이에 따라 대퇴경골각에 미치는 영향 (The Effects of Femorotibial Angle of Contact laterally Wedged Insoles With Strapping of varying elevations)

  • 이상용;박성진
    • 대한정형도수물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.44-50
    • /
    • 2006
  • The purpose of this study is to assess the radiographic effects of normal person with contact laterally wedged insoles with strapping of varying elevations. Eight person who were randomized into group according to their birth dates and wedge elevation, participants wore contact laterally wedged insoles with strapping with elevation of 9, 15, 21mm. Standing radiographs were used to analyze the femorotibial angle for each subject, The result of repeated measures ANOVA's reveled that laterally wedged insoles with strapping of varying elevations produced significantly the femorotibial angle. The degree of change in femorotibial angle with the insole with strapping was effected by the tilt of the lateral wedge(P<0.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and later compartment forces in the knee varus-valgus deformity.

  • PDF

마비 환자의 정상적 보행을 위한 능동형 단하지 보조기 개발 (Development of the Active Ankle Foot Orthosis to Induce the Normal Gait for the Paralysis Patients)

  • 황성재;김정윤;황선홍;박선우;이진복;김영호
    • 대한인간공학회지
    • /
    • 제26권2호
    • /
    • pp.131-136
    • /
    • 2007
  • In this study, we developed an active ankle-foot orthosis(AAFO) which can control dorsi/ plantar flexion of the ankle joint to prevent foot drop and toe drag during walking. 3D gait analyses were performed on five healthy subjects under three different gait conditions: the normal gait without AFO, the SAFO gait with the conventional plastic AFO, and the AAFO gait with the developed AFO. As a result, the developed AAFO preeminently induced the normal gait compared to the SAFO. Additionally, AAFO prevented foot drop by proper plantarflexion during loading response and provided enough plantarflexion moment as a driving force to walk forward by sufficient push-off during pre-swing. AAFO also could prevent toe drag by proper dorsiflexion during swing phase. These results indicate that the developed AAFO may have more clinical benefits to treat foot drop and toe drag, compared to conventional AFOs, and also may be useful in patients with other orthotic devices.

밀착성 외측 쐐기 스트랩 깔창이 내반슬 골관절염 환자의 대퇴경골각에 미치는 영향 (The Effects of Femorotibial Angle of a Contact Lateral-Wedged Insole with Strapping in Patients with Varus Deformity Osteoarthritis of the Knee)

  • 이상용
    • 대한정형도수물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose are to assess the efficacy of a contact lateral-wedged insole with strapping on the femorotibial angle in patients with varus deformity osteoarthritis of the knee after treatment period. 25 outpatients with knee osteoarthritis (OA) were randomized to be treated with a contact lateral-wedge insole with strapping. Standing radiographs were used to analyze the femorotibial angle for each subject. The result of repeated two-way ANOVA's reveled that a contact lateral-wedged insole with strapping produced significantly differences in the femorotibial angle between groups after treatment period (P<0.05). and repeated one-way ANOVA's reveled that it produced significantly differences in the femorotibial angle between experimental groups after treatment period (P<0.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and later compartment forces in the knee varus-valgus deformity.

  • PDF

The immediate effects of foot pressure based insole on ankle dorsiflexion range of motion, postural sway, and muscle activation in healthy adults with genu varum

  • Chun, Hye-Lim;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.164-171
    • /
    • 2018
  • Objective: The purpose of this research was to determine the immediate effects of wearing a foot-pressure-based insole (FPBI) on ankle dorsiflexion range of motion (DFROM), postural sway, and muscle activation in healthy individuals with genu varum. Design: Cross-sectional study. Methods: This study was conducted on thirteen adults, with six male and seven females subjects. The mean age was 24.08 years. Foot pressure was measured to apply the FPBI and the weight bearing lunge test was performed with the application of a flat insole (FI) and FPBI. Examination was randomly performed in four conditions to measure both postural sway and muscle activation. All participants applied both the FI and FPBI with four conditions. The four conditions were as follows: 1) Romberg test posture with eyes closed, 2) Romberg test posture with eyes opened, 3) dominant single leg standing with eyes opened, and 4) non-dominant single leg standing with eyes opened. Results: For ankle DFROM between the FI and FPBI, a significant increase was observed in both the dominant and non-dominant leg (p<0.05). For postural sway between the FI and FPBI in the Romberg test posture with eyes closed and dominant single leg standing with eyes opened conditions, a significant decrease was observed (p<0.05). However, the postural sway between FI and FPBI in the Romberg test posture with eyes opened and non-dominant single leg standing with eyes opened, no significant decrease was observed. Also, there were no significant effects on muscle activation between the application of the FI and FPBI. Conclusions: The result showed that FPBI immediately improved ankle DFROM and postural sway. It seems that FPBI may improve genu varum in healthy individuals with genu varum.

국내 뇌성마비 환자에서의 장애인보조기구 지원현황 (Current Situation of Assistive Devices and Appliances Provision for Persons with Cerebral Palsy in Korea)

  • 김성우;전하라;신지철;차준민;육태미;김지용
    • 보건행정학회지
    • /
    • 제28권2호
    • /
    • pp.145-150
    • /
    • 2018
  • Background: The aim of this study was to investigate the current state of the assistive devices and appliances provision system for cerebral palsy patients registered with brain disability. Methods: From 2003 to 2013, we analyzed the records of cerebral palsy patients who had assistive devices and appliances provisioned at least once in their lives based on National Health Information Database. Patients with cerebral palsy were divided into three groups: infants and toddlers, school age and adolescence, and adults. Results: Data on short leg plastic orthoses, ankle joint orthoses, and wheelchair were mainly analyzed. The types of ankle joint orthoses divided into three categories: limited, $90^{\circ}$ limited, and Klenzac. Limited ankle joint orthoses was most frequently supported of the three in all age groups. Powered wheelchair and scooter were most supported to adult patients. When the re-supply duration was evaluated, the duration was suitable to the duration on guideline of regulation of re-supplement according to the related laws in adult patients but not in infants/toddlers and school age/adolescence as the actual re-supplement duration was much shorter than the reference value. Conclusion: This study confirmed the pattern of assistive devices and appliances supply differed depending on the age of cerebral palsy patients.

The Effects of Different Angles of Wedged Insoles on Knee Varus Torque in Healthy Subjects

  • Jung, Do-Young;Kwon, Oh-Yun;Yi, Chung-Hwi;Kim, Young-Ho;Kim, Jang-Hwan
    • 한국전문물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.31-41
    • /
    • 2004
  • The purpose of this study was to examine the effect of the angle of a wedged insole on knee varus torque during walking. Fifteen healthy subjects were recruited. Knee varus torque was measured using three-dimensional motion analysis (Elite). Knee varus torque was normalized to gait cycle (0%: initial contact; 100%: ipsilateral initial contact) and stance phase (0%: initial contact; 100%: ipsilateral toe off). The average peaks of knee varus torque during the stance phase of the gait cycle according to the different insole angles (10 or 15 degrees) were compared using one-way ANOVA with repeated measures. The results showed that in the early stance phase, the average peak knee varus torque increased significantly for both the medial 10 and 15 degree wedged insole conditions and decreased significantly for both the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p<.05). However, there were no significant differences between the 10 and 15 degree wedged insole conditions with either the medial or lateral wedged insole (p>.05). In the late stance phase, the average peak knee varus torque increased significantly for the medial 10 and 15 degree wedged insole conditions (p<.05), but not for the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p>.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and lateral compartment forces in the knee varus-valgus deformity. Further studies of the effects of wedged insole angle on knee varus torque in patients with medial-lateral knee osteoarthritis are needed.

  • PDF