Modified mixing coefficient for the crossflow between sub-channels in a 5 × 5 rod bundle geometry

  • Lee, Jungjin;Lee, Jun Ho;Park, Hyungmin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2479-2490
    • /
    • 2020
  • We performed experiments to measure a single-phase upward flow in a 5 × 5 rod bundle with spacer grids using a particle image velocimetry, focusing on the crossflow. The Reynolds number based on the hydraulic diameter and the bulk velocity is 10,000. The ratio of pitch between rods and rod diameter is 1.4 and spacer grid is installed periodically. The turbulence in the rod bundle results from the combination of a forced mixing and natural mixing. The forced mixing by the spacer grid persists up to 10Dh from the spacer grid, while the natural mixing is attributed to the crossflow between adjacent subchannels. The combined effects contribute to a sinusoidal distribution of the time-averaged stream-wise velocity along the lateral direction, which is relatively weak right behind the spacer grid as well as in the gap. The streamwise and lateral turbulence intensities are stronger right behind the spacer grid and in the gap. Based on these findings, we newly defined a modified mixing coefficient as the ratio of the lateral turbulence intensity to the time-averaged streamwise velocity, which shows a spatial variation. Finally, we compared the developed model with the measured data, which shows a good agreement with each other.

Selection of the Optimal Decision Tree Model Using Grid Search Method : Focusing on the Analysis of the Factors Affecting Job Satisfaction of Workplace Reserve Force Commanders (격자탐색법을 이용한 의사결정나무 분석 최적 모형 선택 : 직장예비군 지휘관의 직장만족도에 대한 영향 요인 분석을 중심으로)

  • Jeong, Chulwoo;Jeong, Won Young;Shin, David
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.40 no.2
    • /
    • pp.19-29
    • /
    • 2015
  • The purpose of this study is to suggest the grid search method for selecting an optimal decision tree model. It chooses optimal values for the maximum depth of tree and the minimum number of observations that must exist in a node in order for a split to be attempted. Therefore, the grid search method guarantees building a decision tree model that shows more precise and stable classifying performance. Through empirical analysis using data of job satisfaction of workplace reserve force commanders, we show that the grid search method helps us generate an optimal decision tree model that gives us hints for the improvement direction of labor conditions of Korean workplace reserve force commanders.

Planning of HVDC System Applied to Korea Electric Power Grid

  • Choi, DongHee;Lee, Soo Hyoung;Son, Gum Tae;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.105-113
    • /
    • 2018
  • This paper proposes pre-analysis on planning of high-voltage direct current (HVDC) transmission system applied to Korea electric power grid. HVDC transmission system for interface lines has been considered as alternative solution for high-voltage AC transmission line in South Korea since constructing new high-voltage AC transmission lines is challenging due to political, environmental and social acceptance problems. However, the installation of HVDC transmission system as interface line in AC grid must be examined carefully. Thus, this paper suggests three scenarios to examine the influences of the installation of HVDC transmission system in AC grid. The power flow and contingency analyses are carried out for the proposed scenarios. Power reserves in metro area are also evaluated. And then the transient stability analysis focusing on special protection scheme (SPS) operations is analyzed when critical lines, which are HVDC lines or high voltage AC lines, are tripped. The latest generic model of HVDC system is considered for evaluating the impacts of the SPS operations for introducing HVDC system in the AC grid. The analyses of proposed scenarios are evaluated by electromechanical simulation.

CNT FEDs with Electron Focusing Structure for HDTV Application

  • Chi, Eung-Joon;Choi, Jong-Sick;Chang, CheolHyeon;Park, Jong-Hwan;Lee, Chul-Ho;Choe, Deok-Hyeon;Lee, Chun-Gyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1008-1011
    • /
    • 2005
  • In this study, the field emission display with carbon nanotube emitter is developed for the large size HDTV application. Two structures for electron beam focusing are developed on the typical top-gate cathode. The metal grid and focusing gate structure are proved to be effective for the focusing. The data switching voltage for the double gate structure is lower than 30V which is competitive value in respect of the cost for driver electronics. The brightness and color gamut are comparable to those of the commercial product such as CRT.

  • PDF

A Study on the Power Loss Monitoring Methods with AMI systems (지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구)

  • Myoung, No-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.

Effect of taper on fundamental aeroelastic behaviors of super-tall buildings

  • Kim, Yong Chul;Tamura, Yukio;Yoon, Sung-Won
    • Wind and Structures
    • /
    • v.20 no.4
    • /
    • pp.527-548
    • /
    • 2015
  • Aeroelastic wind tunnel experiments were conducted for conventional and tapered super-tall building models to investigate the effect of taper on fundamental aeroelastic behaviors in various incident flows. Three incident flows were simulated: a turbulent boundary-layer flow representing urban area; a low-turbulent flow; and a grid-generated flow. Results were summarized focusing on the effect of taper and the effect of incident flows. The suppression of responses by introducing taper was profound in the low-turbulence flow and boundary-layer flow, but in the grid-generated flow, the response becomes larger than that of the square model when the wind is applied normal to the surface. The effects of taper and incident flows were clearly shown on the normalized responses, power spectra, stability diagrams and probability functions.

An Analysis on standardization trend of home network energy management based on Smart Grid network (스마트그리드 기반 홈네트워크의 에너지 관리 표준화 동향 분석)

  • Cho, Pyung-dong;Choi, Mun-hwan;Lee, Sang-mu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.491-494
    • /
    • 2012
  • Smart grid can be viewed as additional network constructed on electrical energy network and has close relationship with ICT. In this paper, we introduce smart grid standardization trends focusing on ITU-T activities and discuss future direction.

  • PDF

Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections (병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석)

  • Jung, Young-Seok;Yu, Byung-Gyu;Kang, Gi-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

The Analysis of Hydropower Development and the Mekong Power Grid on Regional Cooperation : Focus on the Greater Mekong Subregion Program

  • Nayeon Shin;Seungho Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.245-245
    • /
    • 2023
  • This paper examines the extent to which the Mekong River Basin countries have achieved socioeconomic benefits based on regional cooperation through the Greater Mekong Subregion (GMS) Program, focusing on hydropower development and the Mekong Power Grid. This study pays attention to the time period from 2012 to 2022. The benefit sharing approach is employed to evaluate the extent to which hydropower development and the Mekong Power Grid have contributed to the regional energy trade in the GMS program. The GMS program was launched by the Asian Development Bank (ADB) in 1992, and the Chinese provinces of Yunnan and Guangxi, Myanmar, Lao PDR, Thailand, Cambodia, and Vietnam have taken an active part in the program. The goals of the GMS program are to achieve poverty alleviation, economic development, and regional cooperation in various sectors, including energy, tourism, and transportation. The GMS Economic Cooperation Program Strategic Framework 2030 (GMS-2030), in 2021, provides a new framework for prosperous and sustainable development in the river basin. In the energy sector, the GMS program has been instrumental in facilitating hydropower development and creating the Mekong Power Grid with the Regional Grid Code (RGC), contributing to economic benefits and promoting regional trade of hydroelectricity. It is argued that the GMS program has enhanced regional cooperation between the riparian countries. Despite such achievements, the GMS program has faced challenges, including the gap of economic development between the riparian countries, socioeconomic and environmental concerns regarding hydropower development between the Upper and Lower Mekong countries, and geopolitical tensions from the US-China rivalry. These challenges should adequately be addressed within the program, which can guarantee the sustainability of the program for the river basin.

  • PDF

Performance Comparison of Machine Learning Models for Grid-Based Flood Risk Mapping - Focusing on the Case of Typhoon Chaba in 2016 - (격자 기반 침수위험지도 작성을 위한 기계학습 모델별 성능 비교 연구 - 2016 태풍 차바 사례를 중심으로 -)

  • Jihye Han;Changjae Kwak;Kuyoon Kim;Miran Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_2
    • /
    • pp.771-783
    • /
    • 2023
  • This study aims to compare the performance of each machine learning model for preparing a grid-based disaster risk map related to flooding in Jung-gu, Ulsan, for Typhoon Chaba which occurred in 2016. Dynamic data such as rainfall and river height, and static data such as building, population, and land cover data were used to conduct a risk analysis of flooding disasters. The data were constructed as 10 m-sized grid data based on the national point number, and a sample dataset was constructed using the risk value calculated for each grid as a dependent variable and the value of five influencing factors as an independent variable. The total number of sample datasets is 15,910, and the training, verification, and test datasets are randomly extracted at a 6:2:2 ratio to build a machine-learning model. Machine learning used random forest (RF), support vector machine (SVM), and k-nearest neighbor (KNN) techniques, and prediction accuracy by the model was found to be excellent in the order of SVM (91.05%), RF (83.08%), and KNN (76.52%). As a result of deriving the priority of influencing factors through the RF model, it was confirmed that rainfall and river water levels greatly influenced the risk.