• Title/Summary/Keyword: Focused Ultrasound

Search Result 146, Processing Time 0.03 seconds

Experiences of High Intensity Focused Ultrasound (HIFU) Treatment in Benign Uterus Neoplasms (자궁양성종양 환자의 고강도 초음파 집속술(HIFU) 치료 경험)

  • Park, Seo A;Kim, Hye Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.403-411
    • /
    • 2018
  • The purpose of this study was to identify the experience of patients with uterine benign neoplasms in response to high-intensity focused ultrasound treatment. The study participants were patients who received high-intensity focused ultrasound treatment after diagnosis of benign uterine neoplasms and were contacted through purposive techniques. Five patients agreed to participate in this study. Data were collected from February, 2018 to May, 2018 at Women's hospital in D city. The interview data were analyzed by the phenomenological analysis method developed by Colaizzi using open-ended questions during in-depth interviews. Three categories emerged from the analysis using Colaizzi's method: 1) Discomfort. 2) Ambivalence. 3) Will and need. These study results contribute to a deeper understanding of the experience of patients with uterine benign neoplasms in response to high-intensity focused ultrasound treatment. Therefore, it should be developed as part of an effective nursing education program to provide evidence-based guidelines and nursing interventions that alleviate health problems in patients receiving high-intensity focused ultrasound treatment and proper nursing understanding of the development of new treatment methods for woman's health.

The Potential Usefulness of Magnetic Resonance Guided Focused Ultrasound for Obsessive Compulsive Disorders

  • Jung, Hyun Ho;Chang, Won Seok;Kim, Se Joo;Kim, Chan-Hyung;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.427-433
    • /
    • 2018
  • Obsessive compulsive disorder is a debilitating condition characterized by recurrent obsessive thoughts and compulsive reactions. A great portion of the obsessive compulsive disorder (OCD) patients are managed successfully with psychiatric treatment such as selective serotonin-reuptake inhibitor and cognitive behavioral psychotherapy, but more than 10% of patients are remained as non-responder who needs neurosurgical treatments. These patients are potential candidates for the neurosurgical management. There had been various kind of operation, lesioning such as leucotomy or cingulotomy or capsulotomy or limbic leucotomy, and with advent of stereotaxic approach and technical advances, deep brain stimulation was more chosen by neurosurgeon due to its characteristic of reversibility and adjustability. Gamma knife radiosurgery are also applied to make lesion targeting based on magnetic resonance (MR) imaging, but the complication of adverse radiation effect is not predictable. In the neurosurgical field, MR guided focused ultrasound has advantage of less invasiveness, real-time monitored procedure which is now growing to attempt to apply for various brain disorder. In this review, the neurosurgical treatment modalities for the treatment of OCD will be briefly reviewed and the current state of MR guided focused ultrasound for OCD will be suggested.

Development of Human-Head-Mimicking Phantom for Brain Treatment Using Focused Ultrasound (집속 초음파 뇌 질환 치료를 위한 두부 유사 팬텀의 개발)

  • Min, Jeonghwa;Kim, Juyoung;Noh, Sicheol;Choi, Heungho
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.433-439
    • /
    • 2013
  • In this study, human head-mimicking phantom was developed for brain disease treatment study using focused ultrasound. Acoustic parameters of skin, skull and brain were investigated through literature investigation and adequate substitutes according to each tissue were suggested. In the case of skin phantom, construction ratio of glycerol-based TMM phantom was controlled to mimic real skin. The suitability of skull substitutes was evaluated through measurement of acoustic parameters. In the case of brain phantom, transparent egg white phantom was used to observe thermal properties of focused ultrasound. Combined human-head-mimicking phantom using each substitutes was fabricated for development of brain disease treatment protocol. Denaturation of brain phantom according to ultrasonic condition was observed for validation.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.

Development of communcation signal interference removal module between High-Intensity Focused Ultrasound Devices using CAN communication (CAN 통신을 이용한 고강도 집속 초음파 디바이스간의 통신 신호 간섭 제거 모듈 개발)

  • Park, Jong-Cheol;Lee, Jin-Wook;Kim, Min-Sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.463-465
    • /
    • 2022
  • The high-intensity focused ultrasound device intermittently operates abnormally due to communication signal interference between the devices during use due to the high frequency radiated during the skin treatment procedure. Communication interference between multi-frequency ultrasound devices can be reduced through CAN communication controller and transceiver design, firmware S/W program and CAN communication module development.

  • PDF

Ultrasonography and Ultrasound-guided Interventions of the Shoulder

  • Moon, Sang Ho;Ko, Kwang Pyo;Baek, Seung Il;Lee, Song
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.172-193
    • /
    • 2015
  • Nowadays shoulder ultrasound is commonly used in the assessment of shoulder diseases and is as accurate as magnetic resonance imaging in the detection of several pathologies. Operator dependence is the main disadvantage of shoulder ultrasound. After adhering to a strict examination protocol, good knowledge of normal anatomy and pathologic processes and an awareness of common pitfalls, it can be used as a focused examination providing rapid, real-time diagnosis, and treatment by ultrasound-guided interventions in desired clinical situations. Also shoulder ultrasound can help the surgeon decide whether treatment will be surgical or nonsurgical. If arthroscopy is planned, sonographic findings help to counsel patients regarding surgical and functional outcomes. If a nonsurgical approach is indicated, ultrasound can be used to follow patients. This review article presents the examination techniques, the normal sonographic appearances and the main pathologic conditions found in shoulder ultrasound. And also addresses a simplified approach to scanning and ultrasound-guided intervention. Knowledge of optimal techniques, normal anatomy, dynamic maneuvers, and pathologic conditions is essential for optimal performance and interpretation of images.

Ultrasound Harmonic Imaging Method based on Harmonic Quadrature Demodulation (하모닉 직교 방식의 초음파 고조파 영상화 기법)

  • Kim, Sang-Min;Song, Jae-Hee;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.79-88
    • /
    • 2009
  • A harmonic quadrature demodulation method to extract the second harmonic component from focused ultrasound signals after a single transmit-receive event is proposed. In the proposed method, the focused ultrasound signal is converted into baseband inphase and quadrature components by multiplying with sine and cosine signals both having twice the center frequency of the transmitted signal and filtering the two modulated signals. The quadrature component is then passed through a Hilbert filter to be added to the inphase component, which leaves only the envelope of the second harmonic component. A novel phase estimation technique is employed in the proposed method to avoid the phase mismatch between the focused signal and the two modulating signals. The proposed method is verified through both theoretical analysis and computer simulations. It is shown that compared to the pulse inversion scheme the proposed method provides almost the same results for stationary targets and significantly improved harmonic to fundamental ratio for moving targets.

A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization (주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

Cell Disruption of Microalgae by Low-Frequency Non-Focused Ultrasound (저주파 초음파를 이용한 미세조류 파쇄)

  • Bae, Myeong-Gwon;Choi, Jun-Hyuk;Park, Jong-Rak;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.111-118
    • /
    • 2020
  • Recently, bioenergy research using microalgae, one of the most promising biofuel sources, has attracted much attention. Cell disruption, which can be classified as physical or chemical, is essential to extract functional ingredients from microalgae. In this study, we investigated the cell disruption efficiency of Chlorella sp. using low-frequency non-focused ultrasound (LFNFU). This is a continuously physical method that is superior to chemical methods with respect to environmental friendliness and low processing cost. A flat panel photobioreactor was employed to cultivate Chlorella sp. and its growth curve was fitted both with Logistic and Gompertz models. The temporal change in cell reduction by cell disruption using LFNFU was fitted with a Logistic model. The experimental conditions that were investigated were the initial concentration of microalgal cells, relative amplitude of output ultrasound waves, processing volume of microalgal cells, and initial pH value. The optimal conditions for the most efficient cell disruption were determined through the various tests.

Temperature Rise due to Nonlinear Propagation of Ultrasound using Weak Shock Theory (Weak Shock Theory를 이용한 초음파의 비선형 전파에 의한 온도 상승)

  • Choi, M.J.;Sung, K.M.;Lee, S.E.;Chung, B.H.;Lee, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.74-75
    • /
    • 1998
  • The present study employs weak shock theory and bio-heat transfer function to predict the temperature rise due to nonlinear propagation of high amplitude ultrasound. The theory shows that, for the focused ultrasound which is assumed to have an gaussian beam profile and has the focal intensity of $1000W/cm^2$, the temperature rise of liver tissue exposed for 1 second to the energy lost during nonlinear propagation goes up to about $30^{\circ}C$. This indicate that it is necessary to consider the nonlinear propagation induced heating enhancement when setting exposure condition of high intensity focused ultrasound used for cancer thermotherapy.

  • PDF