• Title/Summary/Keyword: Focused Ultrasound

Search Result 146, Processing Time 0.025 seconds

Adventitial Cystic Disease of the Common Femoral Vein Mimicking Deep Venous Thrombosis: A Case Report (심부 정맥 혈전으로 오인된 총대퇴정맥에 생긴 외막낭성질환: 증례 보고)

  • Sun Ha Min;Jae Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1315-1320
    • /
    • 2021
  • Adventitial cystic disease of the vein is a rare vascular disease. Herein, we report a case of adventitial cystic disease of the common femoral vein that was initially misdiagnosed as deep venous thrombosis in a 41-year-old male who presented with leg swelling. We focused on the imaging findings and compared them with those of deep venous thrombosis.

A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia (전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구)

  • Park, Mun-Kyu;Noh, Si-Cheol;Park, Jae-Hyun;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.

A Study on the Structural Relation among Purchase Decision Factors of Medical Devices, Satisfaction and Repurchasing Intention : Focused on Ultrasound Imaging System (의료기기의 구매결정요인과 만족 및 재구매 의도의 구조적 관계에 관한 연구 : 초음파영상진단장치를 중심으로)

  • Jung, Tae-young;Seo, Geon-seok;Kim, Su-beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3308-3314
    • /
    • 2015
  • The purpose of this study is to investigate the casual relationships among purchase decision factors of medical devices, satisfaction and repurchasing intention. Data of this study is a 2012 survey on medical institutions using medical devices of MW(ministry of health and welfare) and We analyzed 116 medical institutions having ultrasound imaging system lager than general hospitals among data. For empirical analysis, we carried out confirmative factor analysis and path-analysis using AMOS 21.0 package. Main results of this study are as follows: First, brand has positive influence on satisfaction and satisfaction has positive impaction on repurchase intention. Second, although not statistically significant, performance and service have positive impaction on satisfaction and price has negative influence on satisfaction. The significance of this study is to provide empirical basis on establishment of efficient marketing strategy and enhancement of competitiveness for the medical device industry.

REVIEW: Dynamic force effects on batteries (종설: 동적 부하가 배터리에 미치는 영향)

  • Sunghyun, Jie;Taeksoo, Jung;Seunghoon, Baek;Byeongyong, Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.669-679
    • /
    • 2022
  • Lithium-ion battery has been used for lots of electronic devices. With the popularization of batteries, researchers have focused on batteries' electrochemical performances by environmental conditions, such as temperature, vibration, shock and charging state. Meanwhile, due to very serious global warming, car companies have started using lithium-ion batteries even in cars, replacing internal combustion engines. However, batteries have been developed based on non-moving systems which is totally different from vehicles. In the line of the differences, researchers have tried to reveal relationship between variables from dynamic systems and batteries. In this review, we discuss the comprehensive effect of vibration and shock on batteries. We firstly summarize vibration profiles and effect of normal vibration on batteries. We also sum up effect of shock and penetration on batteries and introduce how ultrasound influences on batteries. Lastly, outlook for the battery design as well as dynamic design of EVs are discussed.

Large-Scale Ultrasound Volume Rendering using Bricking (블리킹을 이용한 대용량 초음파 볼륨 데이터 렌더링)

  • Kim, Ju-Hwan;Kwon, Koo-Joo;Shin, Byeong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.117-126
    • /
    • 2008
  • Recent advances in medical imaging technologies have enabled the high-resolution data acquisition. Therefore visualization of such large data set on standard graphics hardware became a popular research theme. Among many visualization techniques, we focused on bricking method which divided the entire volume into smaller bricks and rendered them in order. Since it switches bet\W8n bricks on main memory and bricks on GPU memory on the fly, to achieve better performance, the number of these memory swapping conditions has to be minimized. And, because the original bricking algorithm was designed for regular volume data such as CT and MR, when applying the algorithm to ultrasound volume data which is based on the toroidal coordinate space, it revealed some performance degradation. In some areas near bricks' boundaries, an orthogonal viewing ray intersects the single brick twice, and it consequently makes a single brick memory to be uploaded onto GPU twice in a single frame. To avoid this redundancy, we divided the volume into bricks allowing overlapping between the bricks. In this paper, we suggest the formula to determine an appropriate size of these shared area between the bricks. Using our formula, we could minimize the memory bandwidth. and, at the same time, we could achieve better rendering performance.

  • PDF

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.391-401
    • /
    • 2004
  • 3D imaging systems using 2D phased arrays have a large number of active channels, compelling to use a very expensive and bulky beamforming hardware, and suffer from low volume rate because, in principle, at least one ultrasound transmit-receive event is necessary to construct each scanline. A high speed 3D imaging method using a cross array proposed previously to solve the above limitations can implement fast scanning and dynamic focusing in the lateral direction but suffer from low resolution except at the fixed transmit focusing along the elevational direction. To overcome these limitations, we propose a new real-time volumetric imaging method using a cross array based on the synthetic aperture technique. In the proposed method, ultrasound wave is transmitted successively using each elements of an 1D transmit array transducer, one at a time, which is placed along the elevational direction and for each firing, the returning pulse echoes are received using all elements of an 1D receive array transducer placed along the lateral direction. On receive, by employing the conventional dynamic focusing and synthetic aperture method along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. In addition, in the proposed method, a volume of interest consisting of any required number of slice images, can be constructed with the same number of transmit-receive steps as the total number of transmit array elements. Computer simulation results show that the proposed method can provide the same and greatly improved resolutions in the lateral and elevational directions, respectively, compared with the 3D imaging method using a cross array based on the conventional fixed focusing. In the accompanying paper, we will also propose a new real-time 3D imaging method using a cross array for improving transmit power and elevational spatial resolution, which uses linear wave fronts on transmit.

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

Indoor Location System based on TDOA between RF and Ultrasonic Signal (RF와 초음파 사이의 TDOA에 기반한 실내 측위시스템)

  • Seo, Young-Dong;Song, Moon-Kyou
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6C
    • /
    • pp.611-618
    • /
    • 2009
  • Recently, an indoor location-aware technology has been focused on as a key technology for context awareness in ubiquitous computing environments. The conventional Cricket system was designed with a non-centralized architecture, which has advantages in terms of user privacy, deployment, scalability, decentralized administration, network heterogeneity, and low cost. In this paper, an indoor location system based on TDOA between RF and ultrasound signals is designed, which improves the Cricket system. A 2.4GHz frequency is employed for transmitting RF messages, which is in an ISM band. The beaconing frequency is doubled to enhance the channel utilization rate. The ultrasonic pulse duration is optimized to increase the coverage of ultrasonic signals. The function of calculating location coordinates is embedded in a listener. The location-update rate and location accuracy are also improved.

The Implementation of TMM test phantom for evaluating the thermal performance in High Intensity Focused Ultrasound system (강력 집속 초음파 시스템의 열적 성능 평가를 위한 팬텀 개발에 관한 기초연구)

  • Yu, Woo-Jin;Noh, Si-Cheol;Park, Moon-Kyu;Min, Hae-Ki;Park, Jae-Hyun;Choi, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.484-485
    • /
    • 2008
  • 초음파는 의학적 진단 및 치료의 목적으로 널리 사용되어 왔다. 일반적으로, 초음파 조사의 생물학적 무해성은 많은 연구를 통하여 보고되었으나, 최근 초음파 집속을 통한 강력 초음파의 사용에 대한 열적 안전성 평가가 중요한 요소로 대두되고 있다. 이에 본 연구에서는 강력 집속 초음파의 전달 에너지와 열적 분포를 측정하여 안전성 평가에 활용 가능한 초음파 열분포 팬텀을 제안하였다. 온도 분포 측정용 팬텀은 초음파 조직유사 팬텀 재료인 한천을 이용하였으며, 음향학적 특성의 유사성을 평가하였다. 온도 효과를 측정하기 위하여 $3{\times}3$의 형태로 온도 센서를 팬텀 내부에 배열하여 초음파 조사에 따른 온도 분포를 측정하였고 온도 측정을 위한 시스템을 개발하여, 초음파 가열 실험을 수행하였다. 본 연구에서 제안된 초음파 온도 분포 측정용 팬텀의 유용성을 확인하였으며, 온도 분포용 팬텀을 통한 강력 집속 초음파 장비의 열적 성능 평가에 적용 될 수 있을 것으로 사료되었다.

  • PDF

A study on the pulsatile flow characteristics of Newtonian and non-Newtonian fluids in the bifurcated tubes (분기관내 뉴턴유체와 혈액의 맥동유동특성에 관한 연구)

  • Seo, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3607-3619
    • /
    • 1996
  • Experimental and numerical studies for three-dimensional pulsatile flows are conducted to investigate the flow characteristics in the bifurcated tubes. Velocity measurements in experimental study were made by both Pulsed Doppler Ultrasound(PDU) machine and Laser Doppler Anemometer(LDA) system. Glycerin is used for experimental study. Experimental results are used to verify the results of the numerical simulation. Flow characteristics of Newtonian fluid and blood in the bifurcated tubes under the steady and pulsatlie flows are numerically investigated. Finite volume method is employed for three-dimensional numerical simulations. Blood is considered as a non-Newtonian fluid and the constitutive equation of blood is used for the numerical analysis. Numerical analyses are focused on the flow patterns for various branch angles ranging from 30.deg. to 90.deg. and diameter ratios such as 1.0, 0.8, and 0.6. Pulsatile flow characteristics of blood are compared with those of Newtonian fluid. Parameter effects on axial velocity, pressure and wall shear stress distribution along the bifurcated tubes are discussed in terms of the branch angle, diameter ratio, and Reynolds number.