• 제목/요약/키워드: Focal distance

검색결과 156건 처리시간 0.025초

저탄소 강판의 레이저 절단에서 자동 초점거리 추적이 절단 품질에 미치는 영향 (Effects of an Auto-tracking of the Focal Distance on the Quality of the Cut Part in the Laser Cutting of a Low Carbon Sheet)

  • 안동규;변경원;유영태
    • 한국공작기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.101-107
    • /
    • 2007
  • The objective of this research work is to investigate into effects of an auto tracking of the focal distance on the quality of the cut part in the cutting of a low carbon sheet using a high-power CW Nd:YAG laser. An auto-tracking system with a capacitance based distance control loop has been employed to perform a real control of the focal distance. In order to examine the influence of the auto-tracking of a focal distance on the optimum focal distance, the kerfwidth, surface roughness and the formation of the cut section, several linear cutting tests have been carried out using the auto-tracking system. The results of experiments have been shown that the optimum focal distance is 0.9mm. In addition, it has been shown that the variation of kerfwidth and the surface roughness of the cut part with control of the focal distance are reduced 40-80% and 30-55% in comparison with those of the cut part without tracking of the focal distance. From the results of the experiments, it has been found that the real time tracking of the focal distance can improve the part quality.

다공초점형(多孔焦点型) 콜리메타의 감도(感度)와 해상력(解像力)에 관(關)한 검토(檢討) (Study on Sensitivity and Resolution of Multihole Focusing Type Collimator)

  • 박성옥;경광현;박준철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.63-70
    • /
    • 1982
  • In order to estimate characteristics and functions of multi hole focusing type collimator, the authors measured the sensitivity and resolution varing with the distance between the face of collimator and source by experimental study. The results obtained with this study are as follows. 1. In comparison with focal distance obtained fram sensitivity measurement of various multi hole focusing type collimator, collimator A, C, E was 10 cm and collimator B, D was 12 cm in focal distance. 2. In regard of resolution of collimators having 10 cm focal distance, collimator A showed the finest resolutions than any other collimator(C, E). 3. By comparison regarding sensitivity by focal dist ante, the shorter the distance than a give focal distance of collimator, the worse the sensitivity of collimator. 4. With regard to resolution by focal distance, the shorter the distance than a given focal distance of collimator, the worse the resolution of collimator.

  • PDF

A Simple Method for Determining Focal Distances Using Talbot Self-Images

  • Spires, Oliver;Sasian, Jose;Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.638-642
    • /
    • 2015
  • We present a simple method to determine the focal distances of lenses with the Talbot self-images. This method uses only one grating, and a priori knowledge of the period of the grating is replaced with a linear relation between the (de)magnified periods of the Talbot images and the lens-to-grating distance. A thick lens whose effective focal length is 500 mm was used to validate the method, and the focal distance of the converging beam was determined with the difference of 0.15% for the nominal focal distance of 521.9 mm. The determined period of the grating with the difference of 0.2% also supports the validation.

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

반사형 Focal Reducer를 가지는 높은 개구수의 대물렌즈 설계 (Optical Design of a High-numerical-aperture Objective with a Reflective Focal Reducer)

  • 이종웅
    • 한국광학회지
    • /
    • 제34권6호
    • /
    • pp.248-260
    • /
    • 2023
  • 낮은 NA의 굴절형 대물렌즈와 반사형 focal reducer로 구성된 NA 0.5의 굴절-반사 대물렌즈를 설계하였다. 굴절형 대물렌즈로는 NA 0.25인 Lister 대물렌즈가 사용되고, 반사형 focal reducer는 구면수차, 코마, 비점수차가 보정된 2구면경계가 사용되었다. 설계된 굴절-반사 대물렌즈는 높은 NA를 가졌음에도 18 mm의 긴 작동거리와 NA 0.25의 Lister 대물렌즈보다 개선된 결상성능을 가지고 있다.

비초점화 영상에서 정칙화법을 이용한 깊이 및 거리 계측 (On the Measurement of the Depth and Distance from the Defocused Imagesusing the Regularization Method)

  • 차국찬;김종수
    • 전자공학회논문지B
    • /
    • 제32B권6호
    • /
    • pp.886-898
    • /
    • 1995
  • One of the ways to measure the distance in the computer vision is to use the focus and defocus. There are two methods in this way. The first method is caculating the distance from the focused images in a point (MMDFP: the method measuring the distance to the focal plane). The second method is to measure the distance from the difference of the camera parameters, in other words, the apertures of the focal planes, of two images with having the different parameters (MMDCI: the method to measure the distance by comparing two images). The problem of the existing methods in MMDFP is to decide the thresholding vaue on detecting the most optimally focused object in the defocused image. In this case, it could be solved by comparing only the error energy in 3x3 window between two images. In MMDCI, the difficulty is the influence of the deflection effect. Therefor, to minimize its influence, we utilize two differently focused images instead of different aperture images in this paper. At the first, the amount of defocusing between two images is measured through the introduction of regularization and then the distance from the camera to the objects is caculated by the new equation measuring the distance. In the results of simulation, we see the fact to be able to measure the distance from two differently defocused images, and for our approach to be robuster than the method using the different aperture in the noisy image.

  • PDF

원거리 입체촬영용 카메라 축간거리 조절을 위한 퍼지추론 시스템 (Design of Fuzzy Inference System for Cameras Inter-Axial Distance Control of Remote Stereoscopic Photographs)

  • 변기식;오세웅;김관형;김민;김현조
    • 한국정보통신학회논문지
    • /
    • 제19권1호
    • /
    • pp.41-49
    • /
    • 2015
  • 일반적으로 원거리 피사체를 입체로 촬영할 경우 두 대의 카메라를 교차하기 보다는 평행으로 놓고 좌우 영상을 획득한다. 이를 위해서 특정거리 피사체에 대하여 축간거리와 렌즈의 초점거리를 다양하게 변화시켜가면서 좌우영상들의 깊이총량을 분석하였다. 이들 분석 작업을 통하여 시각적 피로와 시각적 불안정을 주지 않는 축간거리와 렌즈의 초점거리에 대한 데이터를 선택하고, 이들 데이터를 통하여 퍼지제어기를 설계하였다. 피사체에 대한 입체영상을 획득하기 위하여 설계한 퍼지제어기로 축간거리와 렌즈의 최대초점거리를 추론하여 안정된 입체영상임을 확인하였다. 설계된 퍼지제어기는 원거리 피사체의 거리만 입력되면 카메라의 축간거리와 카메라 최대 초점거리 범위가 설정되는 동적 시스템 설계에 활용될 수 있음을 확인하였다.

도심영상 입체 가시화 중 발생하는 원거리 환영현상 해소를 위한 3차원 파노라믹 모자이크 (3D Panoramic Mosaiciking to Silppress the Ghost Effect at Long Distance Scene for Urban Area Visualization)

  • 전재춘;김형석
    • 대한전자공학회논문지SP
    • /
    • 제42권4호
    • /
    • pp.87-94
    • /
    • 2005
  • 3차원 영상 모자이크 방법은 도심지의 도로를 따라 움직이는 카메라로부터 취득된 영상을 3차원 다중 투영평면에 투영하여 도심지를 입체적으로 가시화하기 위한 것이다. 카메라가 교차로와 같은 원거리 가시 지점을 통과할 때, 취득된 영상에 대해 3차원 영상 모자이크 방법을 적용 하면, 모자이크 된 영상에서 동일한 대상물의 영상이 반복하여 나타난다. 이 현상을 환영현상(ghost effect)이라고 하는데, 이 환영현상을 줄이기 위해서 원거리 대상물이 있는 곳의 영상 프레임을 찾고, 이 곳에 나타나는 환영현상을 효과적으로 제거하는 알고리즘을 제안하였다. 제안한 알고리즘은 3차원 공간에서 계산된 가상의 초점과 영상 프레임의 초점을 지나는 벡터를 이용하여 영상 프레임들을 3차원 다중평면에 투영 하는 것이다. 이를 위한 가상 초점은 원거리 대상물이 보이기 시작하는 영상 프레임과 원거리 대상물이 사라지기 시작하는 영상 프레임을 이용하여 계산된다. 본 논문에서는 원거리 대상물 지역에 제안한 방법을 적용했을 때, 환영현상이 효과적으로 제거될 수 있음을 실험적으로 보였다

Focal length에 의한 전자 렌즈의 제어 신호 생성을 위한 하드웨어 설계 (Hardware Design for the Control Signal Generation of Electron Optic by Focal Length)

  • 임선종;이찬홍
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.96-100
    • /
    • 2007
  • Condenser lens and objective lens are used to demagnify the image of the crossover to the final spot size. In lens, electrons are focused by magnetic fields. This fields is fringing field. It is important in electron focusing. Electron focusing occurs the radial component field and axial component field. Radial component produces rotational force and axial component produces radial force. Radial force causes the electron's trajectory to curve toward the optic axis and corss it. Focal length decreases as the current of lens increases. In this paper, we use the focal length for desiging the hardware of lens current control and present the results.