• Title/Summary/Keyword: Flyback transformer

Search Result 99, Processing Time 0.023 seconds

Design and Electromagnetic Characteristics of Planar Transformer (평면변압기의 설계와 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yeon;Kim, Jong-Ryung;Oh, Young-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.109-116
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8 W capacity, with 70 V input voltage and 8.2 V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 $\mu$H, which was the inductance efficiency of'85∼87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 Ω and 0.25 Ω respectively, On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96∼0.97 under 120 kHz switching frequency. The inductance rapidly increased as the thickness of the core plane increased until it became 1.4 mm but under the thickness more than 1.4 mm, there was no substantial change. Therefore, the critical value of the plane thickness of core was 1.4 mm. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

Study on Transformer and Inductor Using Equivalent Air gap to Partial Flux Saturation (국부적 자속 포화 현상을 이용한 리엑터 및 변압기의 공극 등가 모델에 관한 연구)

  • Park, Sung-Jun;Lee, Sang_Hun;Kim, Jeong-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.103-112
    • /
    • 2014
  • BY the Transformers and reactors, the input electrical energy is converted into magnetic energy. At the end through the magnetic energy was passed at the output parameter. Specially At the flyback transformer or a reactor airgap were designed to contain more magnetic energy. But that work is very difficult for the optimal design. It is that Contradictions are between the length of the Air-gap, Winding inductance, DC bias. As to e Several conflicting conditions in order to determine the optimum Air-gap has a lot of experience and trial & error is necessary. The approach proposed in this paper, the auxiliary winding on the core attached to part of primary core, that by applying a DC voltage has a dramatic effect like Core with designed Air-gap. This inventiveness and advantage is to regulate arbitrarily the Saturation Flux Quantity by the input signal to secondary winding. Accordingly obtained the biggest effect is that increasing limits of the saturation current destined by the material and shape of the conventional core. In other words, that can decreas the size of the transformer and reactor, While maintaining the current saturation capacity. This paper, prove its effect as using the local flux saturation in transformers and reactors for research by the computer program using the finite element method (FEM) simulation, followed by actual experiment to verify

Novel Adaptive Blanking Regulation Scheme for Constant Current and Constant Voltage Primary-side Controlled Flyback Converter

  • Bai, Yongjiang;Chen, Wenjie;Yang, Xiaoyu;Yang, Xu
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1469-1479
    • /
    • 2017
  • Primary-side regulation (PSR) scheme is widely applied in low power applications, such as cell phone chargers, network adapters, and LED drivers. However, the efficiency and standby power requirements have been improved to a high standard due to the new trends of DOE (Department Of Energy) Level VI and COC (Code Of Conduct specifications) V5. The major drawbacks of PSR include poor regulation due to inaccurate feedback and difficulty in acquiring acceptable regulation. A novel adaptive blanking strategy for constant current and constant voltage regulation is proposed in this paper. An accurate model for the sample blanking time related to transformer leakage inductance and the metal-oxide-semiconductor field-effect transistor (MOSFET) parasitic capacitance is established. The proposed strategy can achieve accurate detection for ultra-low standby power. In addition, numerous control factors are analyzed in detail to eliminate the influence of leakage inductance on the loop stability. A dedicated controller integrated circuit (IC) with a power MOSFET is fabricated to verify the effectiveness of the proposed control strategy. Experimental results demonstrated that the prototype based on the proposed IC has excellent performance.

High efficiency flyback converter using coaxial cable transformer (동축권선 트랜스포머를 이용한 고효율 플라이백 컨버터)

  • Kim, Do-Hyun;Moon, Sol;Kim, Chan-In;Park, Joung-hu
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.187-188
    • /
    • 2011
  • 본 논문은 SMPS 및 가전기기와 휴대 전자기기 등에서 전원회로로 폭넓게 사용되고 있는 플라이백 컨버터의 트랜스포머를 기존의 샌드위치권선 방식이 아닌 동축권선 방식을 적용하여 기존의 샌드위치권선 방식보다 우수한 1,2차 커플링을 지니는 트랜스포머를 제안한다. 제안된 트랜스포머를 적용한 컨버터는 기존의 컨버터에 비하여 동일한 조건에서 보다 우수한 효율을 나타내고 있다. 제안된 컨버터용 트랜스포머의 구조 및 커플링을 설명하고 커플링계수를 비교 한 후 34[W]급 프로토 타입을 이용하여 검증하였다.

  • PDF

Electromagnetic Analysis for a Planar Transformer Using Finite Element Method (유한 요소법을 이용한 평면 변압기 전자기 해석)

  • Chang, Doo-Won;Joo, Hyeong-Gil
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.177-179
    • /
    • 2008
  • 최근 전원부의 소형화 경향에 따라 에너지 변환 소자인 변압기의 소형 경량화 요구가 가속화 되고 있다. 전원부의 고효율 소형화를 위해서 평면 변압기가 대두되고 있다. 이에 따라 본 논문에서는 8[W]급 플라이-백(Flyback) 평면 변압기의 PCB(Printed Circuit Board) 패턴을 FERROXCUBE 사의 평면 변압기 설계 방법을 따라 개념 설계를 하였다. 120[kHz]의 스위칭 주파수에서 동작하는 평면 변압기의 자계 분포(magnetic intensity), 와전류(eddy current), 전계 분포(electric intensity)를 유한 요소법(Finite Element Method)을 이용하여 분석하였다.

  • PDF

The small signal analysis of current-mode controlled converter (전류모드제어형 컨버터의 소신호 제어 특성)

  • Song, Yo-Chang;Kim, Young-Tae;Kim, Cherl-Jim
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.968-970
    • /
    • 2001
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.

  • PDF

Analysis and Design of DC-DC Converter with Independent Dual Outputs (독립적인 이중 출력을 갖는 DC-DC 컨버터의 해석 및 설계)

  • Heo, Tae-Won;Park, Ji-Ho;Kim, Dong-Wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.171-178
    • /
    • 2005
  • The proposed dual-output DC-DC converter that bases on flyback converter can obtain two output voltage with non-isolated main-output and isolated sub-output at the same time using single-winding high frequency transformer. It can solve problems in multi-winding converter that use one main-switch, and also control quality of isolated sub-output voltage can be improved by additional sub-switch to the second. For analysis and design of the proposed converter system, converters are classified as operation mode from switching state and are become modeling by applying state space averaging method. Steady-state characteristics and dynamic characteristics are analyzed by DC component and perturbation component from state space averaging model. From experiment converter, validity of analysis and design for the propose converter system is confirm.

Novel Multiple Output Converter using Quasi Load

  • Choi, Kyu-Sik;Hyun, Byeong-Chul;Lee, Seoung-Woon;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.125-126
    • /
    • 2010
  • In this paper, a novel multiple output converter using quasi load is proposed. Conventional multiple output converters using multi-winding transformer has poor output voltage regulations. To solve this problem, there are many proposals like post regulation method, weighted control method, and etc. However, the post regulation method regulates output voltage tightly but its conduction loss and cost are increased. And the weighted control can achieve high efficiency and low cost but its regulation is not enough. To solve these problems, this paper proposes a novel multiple output converter using quasi load. The proposed method uses a quasi load which acts like an active dummy load for tight regulation but there is rarely increase of loss and cost. The proposed method is verified by hardware test by two output(24V and 15V) flyback type converter.

  • PDF

Simulation &Analysis of Conducted EMI in Switched Mode Power Supplies (스위치 모드 파워 서플라이에서의 전도 전자파 장애의 시뮬레이션과 분석)

  • Lee, Dong-Young;Lee, Jae-Ho;Min, Seung-Hyeon;Cho, Bo-Hyung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.122-129
    • /
    • 2001
  • Exact simulation of conducted EMI in switched mode power supplies is proposed. In order to achieve exact simulation, PSPICE active component ABM model and modified transformer model are proposed. Each model parameter is extracted from measurements and data-books. PSPICE simulation results with high frequency PCB pattern model are accordant with EMI measurements for a 50[W] isolated flyback converter. EMI relations of each component and EMI patterns are analyzed.

  • PDF

An Efficient Clamp to Reduce Switch Voltage Stress of Forward Converter (포워드 컨버터의 스위치 전압 스트레스 감소를 위한 효율적 클램프)

  • Kim, Marn-Go
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2016
  • In this study, an efficient clamp is proposed to reduce the switch voltage stress of a forward converter. The proposed clamp consists of a conventional LC snubber, a tertiary winding, and a diode. When the switch is turned OFF, the magnetizing inductor energy of the transformer is recovered directly into the flyback output, which is the tertiary winding and diode network, instead of circulating in the LC snubber. Therefore, switch voltage stress and circulating current caused by the magnetizing inductor energy are reduced. This condition improves the efficiency of the forward converter with limited switch voltage stress. A theoretical analysis and the design guidelines of the proposed converter are provided. Experimental results are also reported.