• 제목/요약/키워드: Flux linkage harmonics

검색결과 8건 처리시간 0.02초

왜곡된 역기전력을 갖는 매입형 영구자석 동기전동기의 쇄교자속 고조파 관측기를 이용한 토크리플 저감 (Torque Ripple Reduction based on Flux Linkage Harmonics Observer for an Interior PM Synchronous Motor including Back EMF Harmonics)

  • 진용신;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.367-375
    • /
    • 2013
  • The mechanical vibration of a PM synchronous motor at low speeds due to the back emf harmonics may be serious problems in some application such as MDPS(Motor driven power steering), electric vehicles. In this paper, torque ripple reduction for an interior PM synchronous motor including back emf harmonics is proposed. The dq flux linkage harmonics of the permanent magnet are estimated on real time by using the dq currents of the real system and the model of the MRAS observer. Based on the estimated flux linkage harmonics, the dq harmonic currents for reducing the torque ripples are compensated on the dq reference currents. The estimation of the flux linkage harmonics by the MRAS observer and the torque ripple reduction of the proposed algorithm was verified by the simulation and experiment.

Torque Ripple Reduction of an Interior PM Synchronous Motor by Compensating Harmonic Currents Based on Flux Linkage Harmonics

  • Nam, Myung Joon;Kim, Jong Hyun;Cho, Kwan-Yuhl;Kim, Hag-Wone;Cho, Younghoon
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1223-1230
    • /
    • 2017
  • The back emf harmonics of a permanent magnet (PM) synchronous motor is a major source of torque ripple. For torque control applications including column fitted MDPS (motor driven power steering) systems, it is essential to reduce the mechanical vibrations due to torque ripples at low speeds. In this paper, a torque ripple reduction algorithm for interior PM synchronous motors is proposed. The harmonic currents that cancel the $6^{th}$ order torque harmonic are added to the nominal dq currents for MTPA (maximum torque per ampere) operation. The compensated harmonic currents are derived from flux linkage harmonics based on a FFT analysis of the back emf harmonics. Simulation and experimental results verify that the $6^{th}$ order torque harmonic and THD of the torque ripple are reduced by compensating the dq harmonic currents.

Effect of IPMSM d-q Axis Parameters According to Magnetic Saturation and Armature Reaction

  • Jang, Kibong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.539-544
    • /
    • 2015
  • FEA was used to analyze inductance and torque of IPMSM. Torque and inductance are analyzed on the dq-axis. It was shown that Ld and Lq have harmonic components, and magnitude as well as phase of the harmonics varies according to the current values. This paper shows the relationship between these inductance harmonics and the 6th harmonic component of torque.

회전자 이동을 고려한 발전기 공극자속 및 유기전압의 고조파 해석 (Harmonics Analysis of Air Gap Flux and Output Voltage in Generator Taking Account of the Rotor Movement)

  • 김창업;정용배;윤승진;박병섭;하현성;노철웅;김송웅;김중한;임달호;고요
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.205-207
    • /
    • 1994
  • This paper presents an analyzing method of the distortion factor of the output voltage in generator on the basis of the stator coil flux linkage calculation. In the simulation, 2 dimensional finite clement method is used considering the rotor movement. As an application of the proposed method, we calculated the harmonics of air gap flux and the output voltage in the 150KW class synchronous generator.

  • PDF

A new Instantaneous Torque Control of PM Synchronous Motor for High Performance Direct Drive Systems

  • Chung, Se-Kyo;Kim, Hyun-Soo;Kim, Chang-Gyun;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.13-16
    • /
    • 1996
  • A new instantaneous torque control technique is presented for a high performance control of a permanent magnet synchronous motor. Using the model reference adaptive system technique, the linkage flux of the motor is estimated and the torque is instantaneously controlled by the proposed torque controller combining with a variable structure control and space vector PWM. The proposed torque control provides the advantage of reducing the torque pulsation caused by the flux harmonics. This control strategy is applied to the high torque PM synchronous motor drives for direct drive systems and is implemented by using a software of the DSP TMS320C30. The experiments are carried out for this system and the results well demonstrate the effectiveness of the proposed control.

  • PDF

매입형 영구자석 동기전동기의 약계자 제어에 따른 전자기적 특성 연구 (Study on The Electromagnetism of Interior Permanent Magnet Synchronous Motor due to Field Weakening)

  • 권순오
    • 전자공학회논문지
    • /
    • 제50권1호
    • /
    • pp.254-260
    • /
    • 2013
  • 본 논문에서는 IPMSM(Interior Permanent Magnet Synchronous Motor)의 약계자 제어에 따른 전자기적특성을 다룬다. IPMSM의 운전 속도 영역을 확장하기 위해 약계자 전류제어가 일반적으로 사용되며 약계자 운전 중에는 전기강판의 자기적 포화에 의해 쇄교자속의 왜형이 발생하게 된다. 따라서 정현파 전류 입력을 위한 전압 파형은 왜형을 갖게 된다. 약계자 전류 증가에 따라 이러한 전압 왜형은 더욱 크게 발생되며 기본파 전압에 비해 상당한 크기의 고조파 전압을 필요로 하게 된다. 이러한 현상을 2차원 유한요소 해석을 이용하여 확인하였으며 시험을 통해 검증하였다. 본 연구 결과를 통해 IPMSM의 특성 분석에 사용되는 d-q축 등가회로 파라미터 즉, 영구자석에 의한 쇄교자속, d-q축 인덕턴스는 산정 단계에서 기본파 물리량으로 계산되므로 약계자 운전시 발생하는 전압 왜형을 예측할 수 없음을 알 수 있다. 결국 주어진 전압에서 얻을 수 있는 속도 예측에 오차를 수반하게 되며 전압고조파에 대한 대책이 필요하다.

회전자 이동을 고려한 발전기 유기전압의 고조파 해석 (Harmonic Analysis of Output Voltage in Synchronous Generator Taking Account of the Rotor Movement)

  • 임달호;김창업;정용배
    • 한국자기학회지
    • /
    • 제5권2호
    • /
    • pp.103-108
    • /
    • 1995
  • 본 논문에서는 돌극형 발전기의 유기전압 고조파 해석 방법을 제안하였다. 해석방법은 회전자 이동을 고려한 2차원 유한요소법을 사용하여 고정자 코일에 쇄교하는 자속을 구하고 이를 DFT로 분석하였다. 제안한 방법의 타당성을 검증하기 위하여 150 KW 동기 발전기의 유기전압 고조파를 구하고 이를 실험차와 비교하였다.

  • PDF

PMSG 적용 가변속 계통연계형 풍력발전 시스템의 통합 시뮬레이션 및 스위치 개방고장 진단기법 연구 (A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions)

  • 김경화;송화창;최병욱
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.65-78
    • /
    • 2013
  • To analyze influences under open fault conditions in switching devices, an integrated simulation and condition monitoring scheme for a permanent magnet synchronous generator (PMSG) based variable speed grid-connected wind turbine system are presented. Among various faults in power electronics components, the open fault in switching devices may arise when the switches are destructed by an accidental over current, or a fuse for short protection is blown out. Under such a faulty condition, the grid-side inverter as well as the generator-side converter does not operate normally, producing an increase of current harmonics, and a reduction in output and efficiency. As an effective way for a condition monitoring of generation system by online basis without requiring any diagnostic apparatus, the estimation schemes for generated voltage, flux linkage, and stator resistance are proposed and the validity of the proposed scheme is proved through comparative simulations.